Label-Free Immunoassay for Sensitive and Rapid Detection of the SARS-CoV-2 Antigen Based on Functionalized Magnetic Nanobeads with Chemiluminescence and Immunoactivity

被引:40
|
作者
Wang, Shanshan [1 ]
Shu, Jiangnan [1 ]
Lyu, Aihua [1 ]
Huang, Xiaoxue [2 ]
Zeng, Weihong [2 ]
Jin, Tengchuan [2 ]
Cui, Hua [1 ]
机构
[1] Univ Sci & Technol China, CAS Key Lab Soft Matter Chem, Collaborat Innovat Ctr Chem Energy Mat, Dept Chem, Hefei 230026, Anhui, Peoples R China
[2] Univ Sci & Technol China, Lab Struct Immunol, CAS Key Lab Innate Immun & Chron Dis, CAS Ctr Excellence Mol Cell Sci,Div Life Sci & Me, Hefei 230027, Anhui, Peoples R China
关键词
AU-AT-AG; GOLD NANOPARTICLES;
D O I
10.1021/acs.analchem.1c03208
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Direct detection of SARS-CoV-2 in biological specimens is often challenging due to the low abundance of viral components and lack of enough sensitivity. Herein, we developed a new type of chemiluminescent functionalized magnetic nanomaterial for sensitive detection of the SARS-CoV-2 antigen. First, HAuCl4 was reduced by N-(aminobutyl)-N-(ethylisoluminol) (ABEI) in the presence of amino magnetic beads (MB-NH2) to generate ABEI-AuNPs, which were directly assembled on the surface of MB-NH2. Then, Co2+ was modified onto the surface to form MB@ABEI-Au/Co2+ (MAA/Co2+). MAA/Co2+ exhibited good chemiluminescence (CL) and magnetic properties. It was also found that it was easy for the antibody to be connected with MAA/Co2+. Accordingly, MAA/Co2+ was used as a sensing interface to construct a label-free immunoassay for rapid detection of the N protein in SARS-CoV-2. The immunoassay showed a linear range from 0.1 pg/mL to 10 ng/mL and a low detection limit of 69 fg/mL, which was superior to previously reported methods for N protein detection. It also demonstrated good selectivity by virtue of magnetic separation, which effectively removed a sample matrix after immunoreactions. It was successfully applied for the detection of the N protein in spiked human serum and saliva samples. Furthermore, the immunoassay was integrated with an automatic CL analyzer with magnetic separation to detect the N protein in patient serums and rehabilitation patient serums with satisfactory results. Thus, the CL immunoassay without a complicated labeling procedure is sensitive, selective, fast, simple, and cost-effective, which may be used to combat the COVID-19 pandemic. Finally, the CL quenching mechanism of the N protein in the immunoassay was also explored.
引用
收藏
页码:14238 / 14246
页数:9
相关论文
共 50 条
  • [31] Evaluation of rapid antigen tests based on saliva for the detection of SARS-CoV-2
    Seitz, Tamara
    Schindler, Stefanie
    Winkelmeyer, Patrick
    Zach, Bernhard
    Wenisch, Christoph
    Zoufaly, Alexander
    Allerberger, Franz
    JOURNAL OF MEDICAL VIROLOGY, 2021, 93 (07) : 4161 - 4162
  • [32] Rapid antigen tests for the detection of SARS-CoV-2: A comment
    Sookaromdee, Pathum
    Wiwanitkit, Viroj
    ATENCION PRIMARIA, 2022, 54 (02):
  • [33] SARS-CoV-2 rapid antigen detection tests Reply
    Peeling, Rosanna W.
    Olliaro, Piero
    Boeras, Debrah
    Fongwen, Noah
    LANCET INFECTIOUS DISEASES, 2021, 21 (08): : 1069 - 1070
  • [34] Study of V2CT x -MXene Based Immunosensor for Sensitive Label-Free Impedimetric Detection of SARS-CoV-2 Spike Protein
    Tasic, Nikola
    Konjevic, Ivan
    Lobato, Alnilan
    Metarapi, Dino
    Finsgar, Matjaz
    Oliveira, Filipa M.
    Sofer, Zdenek
    Gusmao, Rui
    Zhang, Xueji
    Hocevar, Samo B.
    ACS APPLIED MATERIALS & INTERFACES, 2024, 16 (23) : 30196 - 30208
  • [35] Development of magnetic particle-based chemiluminescence immunoassay for measurement of SARS-CoV-2 nucleocapsid protein
    Xu, Ye
    Xia, Chuan
    Zeng, Xuan
    Qiu, Yilan
    Liao, Minjing
    Jiang, Qing
    Quan, Meifang
    Liu, Rushi
    JOURNAL OF VIROLOGICAL METHODS, 2022, 302
  • [36] Rapid and Sensitive Detection of Antigen from SARS-CoV-2 Variants of Concern by a Multivalent Minibinder-Functionalized Nanomechanical Sensor
    Agarwal, Dilip Kumar
    Hunt, Andrew C.
    Shekhawat, Gajendra S.
    Carter, Lauren
    Chan, Sidney
    Wu, Kejia
    Cao, Longxing
    Baker, David
    Lorenzo-Redondo, Ramon
    Ozer, Egon A.
    Simons, Lacy M.
    Hultquist, Judd F.
    Jewett, Michael C.
    Dravid, Vinayak P.
    ANALYTICAL CHEMISTRY, 2022, 94 (23) : 8105 - 8109
  • [37] A rapid lateral flow immunoassay strip for detection of SARS-CoV-2 antigen using latex microspheres
    Shen, Lin
    Zhang, Qihan
    Luo, Xiaolu
    Xiao, Haolin
    Gu, Miao
    Cao, Liangli
    Zhao, Feijun
    Chen, Zhencheng
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2021, 35 (12)
  • [38] Evaluation of COVID-19 Antigen Fluorescence Immunoassay Test for Rapid Detection of SARS-CoV-2
    Kiro, Vandana Vijayeta
    Gupta, Ankesh
    Singh, Parul
    Sharad, Neha
    Khurana, Surbhi
    Prakash, S.
    Dar, Lalit
    Malhotra, Rajesh
    Wig, Naveet
    Kumar, Arvind
    Trikha, Anjan
    Mathur, Purva
    JOURNAL OF GLOBAL INFECTIOUS DISEASES, 2021, 13 (02) : 91 - 93
  • [39] Electrochemical immunosensor for rapid and highly sensitive detection of SARS-CoV-2 antigen in the nasal sample
    Mehmandoust, Mohammad
    Gumus, Z. Pinar
    Soylak, Mustafa
    Erk, Nevin
    TALANTA, 2022, 240
  • [40] Multiplex Label-Free Kinetic Characterization of Antibodies for Rapid Sensitive Cardiac Troponin I Detection Based on Functionalized Magnetic Nanotags
    Orlov, Alexey, V
    Malkerov, Juri A.
    Novichikhin, Denis O.
    Znoyko, Sergey L.
    Nikitin, Petr, I
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2022, 23 (09)