The minimum data set pressure ulcer indicator: Does it reflect differences in care processes related to pressure ulcer prevention and treatment in nursing homes?

被引:80
|
作者
Bates-Jensen, BM
Cadogan, M
Osterweil, D
Levy-Storms, L
Jorge, J
Al-Samarrai, N
Grbic, V
Schnelle, JF
机构
[1] Univ Calif Los Angeles, Sch Med, Div Geriatr, Los Angeles, CA USA
[2] Univ Calif Los Angeles, Sch Nursing, Los Angeles, CA 90024 USA
[3] Univ Calif Los Angeles, Borun Ctr Gerontol Res, Reseda, CA USA
[4] Univ Calif Los Angeles, Los Angeles Jewish Home Aging, Reseda, CA USA
[5] Sepulveda Geriatr Res Educ & Clin Ctr, Greater Los Angeles Vet Affairs Healthcare Syst, Sepulveda, CA USA
关键词
Minimum Data Set; pressure ulcer care; quality indicators;
D O I
10.1046/j.1532-5415.2003.51403.x
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
OBJECTIVES: To determine whether nursing homes (NHs) that score in the extreme quartiles of pressure ulcer (PU) prevalence as reported on the Minimum Data Set (MDS) PU quality indicator provide different PU care. DESIGN: Descriptive, cohort. SETTING: Sixteen NHs. PARTICIPANTS: Three hundred twenty-nine NH residents at risk for PU development as determined by the PU Resident Assessment Protocol of the MDS. MEASUREMENTS: Sixteen care process quality indicators (10 specific to PU care processes, five related to nutrition, and one related to incontinence management) were scored using medical record data, direct human observation, interviews, and data from wireless thigh movement monitors. RESULTS: There were no differences between homes with low- and high-PU prevalence rates reported on the MDS PU quality indicator on most care processes. NHs with high PU prevalence rates used pressure-reduction surfaces more frequently and were better at documentation of four wound characteristics when PUs were present. No measure of PU care processes was better in low-PU NHs. Neither low- nor high-PU prevalence NHs routinely repositioned residents every 2 hours, even though 2-hour repositioning was documented in the medical record for nearly all residents. CONCLUSION: The assumption that homes with fewer PUs and thus low PU prevalence according to the MDS quality indicator are providing better PU care was not supported in this sample. NHs that scored low on the MDS PU quality indicator did not provide significantly better care than NHs that scored high. All NHs could improve PU prevention, as evidenced by the poor performance on prevention care processes by low- and high-PU NHs. The MDS PU quality indicator is not a useful measure of the quality of PU care in NHs and can be misleading if not presented with an explanation of the meaning of the indicator.
引用
收藏
页码:1203 / 1212
页数:10
相关论文
共 50 条
  • [21] The National Expert Standard Pressure Ulcer Prevention in Nursing and pressure ulcer prevalence in German health care facilities: a multilevel analysis
    Wilborn, Doris
    Grittner, Ulrike
    Dassen, Theo
    Kottner, Jan
    JOURNAL OF CLINICAL NURSING, 2010, 19 (23-24) : 3364 - 3371
  • [22] Keep the pressure Off! Pressure ulcer prevention and treatment strategies in the intensive care unit
    Freeland, N.
    Evans, B.
    Atkinson, M.
    Witscheber, C.
    Kiseleski, C.
    Pavlik-Mcgowan, B.
    Williams, D.
    Vanhouten, C.
    Comerford, M.
    Moynihan, H.
    Berry, C.
    CRITICAL CARE NURSE, 2007, 27 (02) : 111 - 111
  • [23] Evidence-Based Education and Nursing Pressure Ulcer Prevention Textbooks: Does It Match?
    Wilborn, Doris
    Halfens, Ruud J.
    Dassen, Theo
    WORLDVIEWS ON EVIDENCE-BASED NURSING, 2009, 6 (03) : 167 - 172
  • [24] Developing a pressure ulcer risk factor minimum data set and risk assessment framework
    Coleman, Susanne
    Nelson, E. Andrea
    Keen, Justin
    Wilson, Lyn
    McGinnis, Elizabeth
    Dealey, Carol
    Stubbs, Nikki
    Muir, Delia
    Farrin, Amanda
    Dowding, Dawn
    Schols, Jos M. G. A.
    Cuddigan, Janet
    Berlowitz, Dan
    Jude, Edward
    Vowden, Peter
    Bader, Dan L.
    Gefen, Amit
    Oomens, Cees W. J.
    Schoonhoven, Lisette
    Nixon, Jane
    JOURNAL OF ADVANCED NURSING, 2014, 70 (10) : 2339 - 2352
  • [25] Pressure ulcers in German nursing homes and acute care hospitals: Prevalence, frequency, and ulcer characteristics
    Lahmann, NA
    Halfens, RJG
    Dassen, T
    OSTOMY WOUND MANAGEMENT, 2006, 52 (02) : 20 - +
  • [26] The Minimum Data Set urinary incontinence quality indicators: Do they reflect differences in care processes related to incontinence?
    Schnelle, JF
    Cadogan, MP
    Yoshii, J
    Al-Samarrai, NR
    Osterweil, D
    Bates-Jensen, BM
    Simmons, SF
    MEDICAL CARE, 2003, 41 (08) : 909 - 922
  • [27] Pressure ulcer prevalence across Welsh orthopaedic units and community hospitals: surveys based on the European Pressure Ulcer Advisory Panel minimum data set
    James, Jane
    Evans, Julie A.
    Young, Trudie
    Clark, Michael
    INTERNATIONAL WOUND JOURNAL, 2010, 7 (03) : 147 - 152
  • [28] Pressure ulcer and patient characteristics - A point prevalence study in a tertiary hospital of India based on the European Pressure Ulcer Advisory Panel minimum data set
    Mehta, Chitra
    George, Joby V.
    Mehta, Yatin
    Wangmo, Namgyal
    JOURNAL OF TISSUE VIABILITY, 2015, 24 (03) : 123 - 130
  • [29] A systematic review of nursing students' attitude and related factors towards pressure ulcer prevention
    Hermis, Alaa Hamza
    Mollaei, Amirabbas
    Vajargah, Pooyan Ghorbani
    Karkhah, Samad
    Takasi, Poorya
    Firooz, Mahbobeh
    Hosseini, Seyed Javad
    Otaghvar, Hamidreza Alizadeh
    Raziani, Yosra
    INTERNATIONAL WOUND JOURNAL, 2023, 20 (08) : 3404 - 3416
  • [30] Deriving a risk-adjustment model for pressure ulcer development using the Minimum Data Set
    Berlowitz, DR
    Brandeis, GH
    Morris, JN
    Ash, AS
    Anderson, JJ
    Kader, B
    Moskowitz, MA
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2001, 49 (07) : 866 - 871