Potentiometric and thermal studies of a coated-wire benazepril-selective electrode

被引:26
|
作者
Khalil, S [1 ]
Abd El-Aliem, S [1 ]
机构
[1] Cairo Univ, Fac Sci, Dept Chem, Fayoum Branch, Al Fayyum 63514, Egypt
关键词
benazepril ion selective electrode; poly(vinyl chloride) membrane; potentiometric titration; drug analysis;
D O I
10.1016/S0731-7085(01)00482-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A coated-wire benazepril-selective electrode based on incorporation of the benazepril-tetraphenylborate ion pair in a poly(vinylchloride) coating membrane was constructed. The influences of membrane composition, temperature, pH of the test solution, and foreign ions on the electrode performance were investigated. The electrode showed a Nernstian response over a benazepril concentration range of 1.26 x 10(-5) to 0.58 x 10(-2) M, at 25 degreesC, and was found to be very selective, precise, and usable within the pH range 2.5-9.2. The standard electrode potentials, E degrees, were determined at 20, 25, 30, 35, 40 and 45 degreesC, and used to calculate the isothermal temperature coefficient (dE degrees /dT) of the electrode. Temperatures higher than 45 degreesC seriously affect the electrode performance. The electrode was successfully used for potentiometric determination of benazepril hydrochloride both in pure solutions and in pharmaceutical preparations. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:25 / 29
页数:5
相关论文
共 50 条
  • [21] Silver(I)-selective coated-wire electrode based on an octahydroxycalix[4]arene derivative
    Mazloum-Ardakani, M
    Ensafi, AA
    Salavati-Niasari, M
    Mirhoseini, H
    ANALYTICAL SCIENCES, 2003, 19 (08) : 1187 - 1190
  • [22] Silver(I)-selective Coated-wire Electrode Based on an Octahydroxycalix[4]arene Derivative
    Mohammad Mazloum Ardakani
    Ali Asghar Ensafi
    Mohammad Salavati Niasari
    Hossain Mirhoseini
    Analytical Sciences, 2003, 19 : 1187 - 1190
  • [23] Highly selective lead(II) coated-wire electrode based on a new Schiff base
    Mazloum-Ardakani, M
    Ensafi, AA
    Naeimi, H
    Dastanpour, A
    Shamlli, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 96 (1-2) : 441 - 445
  • [24] Coated-wire copper(II)-selective electrode based on phenylglyoxal-α-monoxime ionophore
    A. Firooz
    M. Mazloum
    J. Safari
    M. Amini
    Analytical and Bioanalytical Chemistry, 2002, 372 : 718 - 722
  • [25] Coated-wire silver ion-selective electrode based on silver complex of cyclam
    Sil, A
    Ijeri, VS
    Srivastava, AK
    ANALYTICAL SCIENCES, 2001, 17 (04) : 477 - 479
  • [26] Silver-selective coated-wire electrode based on resorc[4]arene neutral carrier
    Mazloum-Ardakani, M
    Salavati-Niasari, M
    Chahooki, SHM
    Amini, MK
    ELECTROANALYSIS, 2002, 14 (05) : 376 - 381
  • [27] PERCHLORATE ION-SELECTIVE COATED-WIRE ELECTRODE BASED ON A MACROCYCLIC SCHIFFS BASE COMPLEX
    LIU, JH
    MASUDA, Y
    SEKIDO, E
    ANALYST, 1990, 115 (08) : 1089 - 1092
  • [28] Potentiometric detection of inorganic anions and cations in capillary electrophoresis with coated-wire ion-selective electrodes
    Kappes, T
    Schnierle, P
    Hauser, PC
    ANALYTICA CHIMICA ACTA, 1997, 350 (1-2) : 141 - 147
  • [29] Potentiometric detection of inorganic anions and cations in capillary electrophoresis with coated-wire ion-selective electrodes
    Kappes, T.
    Schnierle, P.
    Hauser, P. C.
    Analytica Chimica Acta, 350 (1-2):
  • [30] Coated-wire ion-selective electrodes for levobetaxolol
    Missel, PJ
    LANGMUIR, 1999, 15 (21) : 7122 - 7124