Evaluation of the Accuracy of Different Combinations of Automatic Registration Selection Factors in Obtaining Tomotherapy Megavoltage Computed Tomography Images

被引:3
|
作者
Lee, Suk [1 ]
Cao, Yuan Jie [1 ]
Shim, Jang Bo [1 ]
Chang, Kyung Hwan [1 ]
Yang, Dae Sik [1 ]
Park, Young Je [1 ]
Yoon, Won Seob [1 ]
Kim, Chul Yong [1 ]
Cho, Kwang Hwan [2 ]
Min, C. K. [2 ]
Kim, Y. H. [2 ]
机构
[1] Korea Univ, Coll Med, Dept Radiat Oncol, Seoul 130701, South Korea
[2] Soonchunhyang Univ, Boocheon Hosp, Dept Radiat Oncol, Bouchon 420767, South Korea
关键词
Tomotherapy; MVCT; Automatic registration control; Scan image control; MODULATED RADIATION-THERAPY; GUIDED HELICAL TOMOTHERAPY; CONFORMAL RADIOTHERAPY; CT IMAGES; HEAD; IMPLEMENTATION; LOCALIZATION; VERIFICATION; DELIVERY; GUIDANCE;
D O I
10.3938/jkps.60.1961
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The purpose of our study is to find the potential best options for the registration selection parameters when performing automatic registration between kilovoltage computed tomography (KVCT) and megavoltage computed tomography (MVCT) images in helical tomotherapy. We compared nine different combinations of automatic registration parameters, including technique and resolution in automatic registration control and tomoimage filtering in scan image control. In the phantom study, we compared the translational and the rotational adjustments between the original position (lateral 0 cm; longitudinal 0 cm; vertical 0 cm) and the manually moved position (lateral 1 cm; longitudinal 1 cm; vertical 1 cm). In the patient study, we compared translational (lateral, longitudinal, vertical) and rotational (pitch, roll, yaw) adjustments between the KVCT and the MVCT images for different anatomic treatment sites. The ranges of translational and rotational displacements in the phantom study were 14.87 +/- 0.12 similar to 15.70 +/- 0.04 mm and 0 degrees similar to 1.03 +/- 0.58 degrees, respectively. In cranial cases, the ranges of translational and rotational root-mean-square values were 4.3 +/- 0.4 mm similar to 5.3 +/- 0.6 mm, and 0.3 +/- 0.3 degrees similar to 0.7 +/- 0.4 degrees, respectively. In the extra cranial cases, the ranges of translational and rotational root-mean-square values were 14.1 +/- 3.6 mm similar to 16.1 +/- 2.5 mm, and 0.5 +/- 0.3 degrees similar to 1.0 +/- 0.5 degrees, respectively. We found that the combination of "full image - super fine" could minimize the mechanical deviations in the cranial case, and that both the combinations of "bone tissue - super fine" and "full image - super fine" were the best options in extra cranial cases.
引用
收藏
页码:1961 / 1966
页数:6
相关论文
共 50 条
  • [21] Automatic exposure control in computed tomography - an evaluation of systems from different manufacturers
    Soderberg, Marcus
    Gunnarsson, Mikael
    ACTA RADIOLOGICA, 2010, 51 (06) : 625 - 634
  • [22] Performance evaluation of automatic anatomy segmentation algorithm on repeat or four-dimensional computed tomography images using deformable image registration method
    Wang, He
    Adam, S. Garden
    Zhang, Lifei
    Wei, Xiong
    Ahamad, Anesa
    Kuban, Deborah A.
    Komaki, Ritsuko
    O'Daniel, Jennifer
    Zhang, Yongbin
    Mohan, Radhe
    Dong, Lei
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : 210 - 219
  • [23] High-dose-rate prostate brachytherapy in a patient with bilateral hip prostheses planned using megavoltage computed tomography images acquired with a helical tomotherapy unit
    Holly, Rick
    Myrehaug, Sten
    Kamran, Asirn
    Sankreacha, Raxa
    Morton, Gerard
    BRACHYTHERAPY, 2009, 8 (01) : 70 - 73
  • [24] Performance evaluation of an AI-based preoperative planning software application for automatic selection of pedicle screws based on computed tomography images
    Jia, Shanhang
    Weng, Yuanzhi
    Wang, Kai
    Qi, Huan
    Yang, Yuhua
    Ma, Chi
    Lu, Weijia William
    Wu, Hao
    FRONTIERS IN SURGERY, 2023, 10
  • [25] An evaluation of systematic errors on marker-based registration of computed tomography and magnetic resonance images of the liver
    Woolcot, Thomas
    Kousi, Evanthia
    Wells, Emma
    Aitken, Katharine
    Taylor, Helen
    Schmidt, Maria A.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 7 : 27 - 31
  • [26] Registration area and accuracy when integrating laser-scanned and maxillofacial cone-beam computed tomography images
    Sun, LiJun
    Hwang, Hyeon-Shik
    Lee, Kyung-Min
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2018, 153 (03) : 355 - 361
  • [27] Evaluation of different segmentation methods of X-ray micro computed tomography images
    Bollmann, Sebastian
    Kleinebudde, Peter
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2021, 606
  • [28] Accuracy of virtual non-contrast images with different algorithms in dual-energy computed tomography
    Takane, Yumi
    Sato, Kazuhiro
    Kageyama, Ryota
    Takano, Hirokazu
    Kayano, Shingo
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2022, 15 (03) : 234 - 244
  • [29] Accuracy of virtual non-contrast images with different algorithms in dual-energy computed tomography
    Yumi Takane
    Kazuhiro Sato
    Ryota Kageyama
    Hirokazu Takano
    Shingo Kayano
    Radiological Physics and Technology, 2022, 15 : 234 - 244
  • [30] Artificial intelligence assisted automatic screening of opportunistic osteoporosis in computed tomography images from different scanners
    Wu, Yan
    Yang, Xiaopeng
    Wang, Mingyue
    Lian, Yanbang
    Hou, Ping
    Chai, Xiangfei
    Dai, Qiong
    Qian, Baoxin
    Jiang, Yaojun
    Gao, Jianbo
    EUROPEAN RADIOLOGY, 2025, 35 (04) : 2287 - 2295