Impact of D-dimer for pathologic differentiation on transesophageal echocardiography in embolic stroke of undetermined source: a single-center experience

被引:1
|
作者
Hira, Kenichiro [1 ,2 ]
Ueno, Yuji [2 ]
Watanabe, Masao [1 ]
Shimura, Hideki [1 ]
Kurita, Naohide [1 ]
Miyamoto, Nobukazu [2 ]
Haginiwa, Haruna [2 ]
Yamashiro, Kazuo [1 ]
Hattori, Nobutaka [2 ]
Urabe, Takao [1 ]
机构
[1] Juntendo Univ, Dept Neurol, Urayasu Hosp, 2-1-1 Tomioka, Urayasu, Chiba 2790021, Japan
[2] Juntendo Univ, Dept Neurol, Sch Med, Bunkyo Ku, 2-1-1 Hongo, Tokyo 1138421, Japan
关键词
Embolic stroke of undetermined source; Transesophageal echocardiography; Patent foramen ovale; D-dimer; MULTIPLE BRAIN INFARCTS; ISCHEMIC-STROKE; RISK-FACTORS; CRYPTOGENIC STROKE; AMERICAN SOCIETY; PREVENTION; GUIDELINES; TERM;
D O I
10.1186/s12883-022-02867-z
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Embolic stroke of undetermined source (ESUS) encompasses diverse embologenic mechanisms, which transesophageal echocardiography (TEE) is critical to detect. Specific markers related to each embolic source in ESUS is not fully studied. We focused on D-dimer levels, and explored the association of D-dimer with potential embolic sources (PES) identified on TEE in ESUS. Methods Consecutive patients with ESUS were included in this study. Clinical characteristics including D-dimer levels were compared between ESUS patients with and without TEE, and among none of, one, and at least two PES in ESUS patients undergoing TEE. Factors related to elevation of D-dimer were analyzed. Results A total of 211 patients (age, 69.3 +/- 13.2 years; 149 males) with ESUS were enrolled. Of these, 115 received TEE, displaying significantly younger age and lower D-dimer levels than patients without TEE (P < 0.05), and 20 (17%), 61 (53%), and 34 (30%) patients were classified into none of, one, and >= two PES, respectively. On multiple logistic regression analysis, D-dimer levels were related to one PES (odds ratio [OR]: 9.01; 95% confidence interval [CI]: 1.00-81.51; P = 0.050) and PES >= two (OR: 9.76; 95% CI: 1.07-88.97; P = 0.043). Right-to-left shunt (RLS) with deep venous thrombosis (DVT)(OR: 13.94; 95% CI: 1.77-109.99; P = 0.012) and without DVT (OR: 3.90; 95% CI: 1.20-12.70; P = 0.024) were associated with elevation of D-dimer. Conclusions D-dimer levels were higher in patients with PES. Among PES, RLS, with and without DVT, were associated with increase of D-dimer in ESUS.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Intensivist-Performed Transesophageal Echocardiography as a Screen for Organ Donation: A Four-Year, Single-Center Experience
    Madden, K. M.
    Wray, T. C.
    Rainbird, K.
    Tawil, I.
    Dettmer, T.
    Azevedo, K.
    Venkataramani, R.
    Marinaro, J.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2021, 21 : 810 - 810
  • [22] Safety of transesophageal echocardiography during transcatheter edge-to-edge tricuspid valve repair: A single-center experience
    Hellhammer, Katharina
    Schueler, Robert
    Eissmann, Mareike
    Schumacher, Brigitte
    Wolf, Alexander
    Bruder, Oliver
    Schmitz, Thomas
    Lambers, Moritz
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [23] D-dimer as a Useful Biomarker in Early Diagnosis of Neonatal Sepsis: A Single-Center Study From Romania
    Lungu, Nicoleta
    Popescu, Daniela-Eugenia
    Gorun, Florin I.
    Nan, Georgiana
    Popa, Zoran L.
    Manea, Aniko
    Brandibur, Timea Elisabeta
    Jura, Ana-Maria Cristina
    Costescu, Sergiu
    Belovan, Biliana
    Boia, Marioara
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [24] Transesophageal Echocardiography-Guided WATCHMAN Implantation Without Contrast Use: A Three-Year, Single-Center Experience
    Shaukat, Muhammad Hamza Saad
    Patel, Hiren
    Alimohammad, Rizwan
    DeLago, Augustin
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (05)
  • [25] Safety of Transesophageal Echocardiography Performed by Intensivists and Emergency Physicians in Critically Ill Patients With Coagulopathy and Thrombocytopenia: A Single-Center Experience
    Wray, Trenton C.
    Schmid, Kristin
    Braude, Darren
    Azevedo, Keith
    Dettmer, Todd
    Tawil, Isaac
    Boivin, Michel
    Marinaro, Jonathan
    JOURNAL OF INTENSIVE CARE MEDICINE, 2021, 36 (01) : 123 - 130
  • [26] Reference Levels of Plasma D-dimer for Normal Pregnant and Their Association with Pregnancy Complications: A Single-center Retrospective Analysis
    Wang, Wenhuan
    Dai, Qiqi
    Pan, Liqin
    Zhang, Hongping
    Wang, Yeping
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2024, 51 (11):
  • [27] Analysis of risk factors for high postoperative D-dimer levels: A single-center nurse-observational study
    Qin, Ling
    Fu, Yan
    Li, Cong
    Chen, Shuang
    Lv, Ying
    Hao, Meijuan
    Zhang, Hao
    Wang, Yanqiu
    INTERNATIONAL JOURNAL OF BIOLOGICAL MARKERS, 2020, 35 (03): : 23 - 28
  • [28] Patent foramen ovale closure by using transesophageal echocardiography for cryptogenic stroke: single center experience in 132 consecutive patients
    Han, Yangyang
    Zhang, Xiquan
    Zhang, Fengwei
    JOURNAL OF CARDIOTHORACIC SURGERY, 2020, 15 (01)
  • [29] Patent foramen ovale closure by using transesophageal echocardiography for cryptogenic stroke: single center experience in 132 consecutive patients
    Yangyang Han
    Xiquan Zhang
    Fengwei Zhang
    Journal of Cardiothoracic Surgery, 15
  • [30] Periinterventional Monitoring during Perctutaneous Mitral Annuloplasty using Real-time 3D Transesophageal Echocardiography : An Initial Single-Center Experience
    Kahlert, Philipp
    Plicht, Bjoern
    Janosi, Alexander
    Erbel, Raimund
    Sack, Stefan
    Buck, Thomas
    AMERICAN JOURNAL OF CARDIOLOGY, 2008, 102 (8A): : 7I - 7I