Surface plasmon resonance biosensor based on graphene layer for the detection of waterborne bacteria

被引:77
|
作者
Daher, Malek G. [1 ]
Taya, Sofyan A. [1 ,2 ]
Colak, Ilhami [3 ]
Patel, Shobhit K. [4 ]
Olaimat, Melad M. [2 ]
Ramahi, Omar [2 ]
机构
[1] Islamic Univ Gaza, Dept Phys, Gaza, Palestine
[2] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
[3] Nisantasi Univ, Dept Elect & Elect Engn, Istanbul, Turkey
[4] Marwadi Univ, Dept Comp Engn, Rajkot, Gujarat, India
关键词
graphene; sensitivity; sensor; surface plasmon resonance; waterborne bacteria; SPR BIOSENSOR; BIMETALLIC STRUCTURE; SENSOR; SENSITIVITY; GOLD;
D O I
10.1002/jbio.202200001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
As a result of the risks that waterborne bacteria bring to the human body, identifying them in drinking water has become a global concern. In this article, a highly sensitive surface plasmon resonance (SPR) biosensor consisting of prism, Ag, graphene, affinity layer and sensing medium is proposed for rapid detection of the waterborne bacteria. Four SPR-based sensors are first studied with the structures prism/Ag/sensing medium, prism/Ag/affinity layer/sensing medium, prism/Ag/graphene/sensing medium, and prism/Ag/graphene/affinity layer/sensing medium. The latter structure is found to have the highest sensitivity so it is considered for further investigations. Four different commonly used prisms are then demonstrated which are N-FK51A, 2S2G, SF10 and BK7. The structure with the prism N-FK51A is found to correspond to the highest sensitivity so it is considered for further investigations. The structure parameters are then optimized. The proposed SPR sensor can achieve high sensitivity of about 221.63 degrees/RIU for Escherichia coli and 178.12 degrees/RIU for Vibrio cholera bacteria with an average value of 199.87 degrees/RIU. We believe that the proposed structure will open a new window in the field of microorganism detections.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Modeling of a Graphene Nanoribbon-based Microfluidic Surface Plasmon Resonance Biosensor
    Barrios, Carlos Angulo
    PLASMONICS, 2022, 17 (02) : 745 - 752
  • [32] Effect of Semiconductor on Sensitivity of a Graphene-Based Surface Plasmon Resonance Biosensor
    Mohanty, Goutam
    Akhtar, Jamil
    Sahoo, Bijay Kumar
    PLASMONICS, 2016, 11 (01) : 189 - 196
  • [33] Simulation and analysis of surface plasmon resonance biosensor based on phase detection
    Yu, XL
    Wang, DX
    Yan, ZB
    SENSORS AND ACTUATORS B-CHEMICAL, 2003, 91 (1-3): : 285 - 290
  • [34] Surface plasmon resonance based biosensor for label free detection of cholesterol
    Gehlot, Rakhee
    Sharma, Kavita
    Mathew, Manoth
    Kumbhat, Sunita
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2008, 47 (12): : 1804 - 1808
  • [35] Detection of digitalis compounds with a surface plasmon resonance-based biosensor
    Balzan, S
    Laricchia, L
    Montali, U
    Ghione, S
    Revoltella, R
    JOURNAL OF HYPERTENSION, 1998, 16 : S135 - S135
  • [36] Target cells capture and detection based on a surface plasmon resonance biosensor
    Chen, X.
    Zhang, L. L.
    Cui, D. F.
    Ge, S.
    Zhang, J.
    Qiu, X.
    MICRO & NANO LETTERS, 2015, 10 (09): : 452 - 455
  • [37] An Array Detection Biosensor Based on Surface Plasmon Resonance Interferometric Imaging
    Wang, Daqian
    Deng, Yan
    Ding, Xiang
    Ding, Lili
    Zhang, Enyao
    Yu, Xinglong
    SENSOR LETTERS, 2011, 9 (02) : 728 - 731
  • [38] Data analysis of surface plasmon resonance biosensor based on phase detection
    Liu, JF
    Xiang, D
    Yu, XL
    Wang, DS
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2): : 778 - 783
  • [39] Sensitivity Analysis of a Graphene based Surface Plasmon Resonance Biosensor in Terms of Number of Graphene Layers
    Bari, Md. Mushfequl
    Sarkar, Ajay Krishna
    Hossain, Sakhawat
    2016 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER & TELECOMMUNICATION ENGINEERING (ICECTE), 2016,
  • [40] Detection of E.Coli Bacteria Using Impedance Spectroscopy and Surface Plasmon Resonance Imaging Based Biosensor
    Mejri, M. B.
    Baccar, H.
    Ktari, T.
    Aouni, M.
    Abdelghani, A.
    SENSOR LETTERS, 2011, 9 (06) : 2130 - 2132