Intercomparison of efficiency transfer software for gamma-ray spectrometry

被引:106
|
作者
Lépy, MC [1 ]
Altzitzoglou, T
Arnold, D
Bronson, F
Noy, RC
Décombaz, M
De Corte, F
Edelmaier, R
Peraza, EH
Klemola, S
Korun, M
Kralik, M
Neder, H
Plagnard, J
Pommé, S
de Sanoit, J
Sima, O
Ugletveit, F
Van Velzen, L
Vidmar, T
机构
[1] CEA, BNM, Lab Natl Henri Becquerel, F-91191 Gif Sur Yvette, France
[2] EC JRC, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
[3] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
[4] Canberra, Middletown, CT 06457 USA
[5] Ctr Estudios Aplicados & Desarollo Nucl, Havana, Cuba
[6] CHB Ecublens, Ctr Univ, Inst Radiophys Appl, IRA OFMET, CH-1015 Lausanne, Switzerland
[7] State Univ Ghent, Inst Nucl Sci, Analyt Chem Lab, B-9000 Ghent, Belgium
[8] BEV, Grp Eichwesen, Metrol Serv, A-1163 Vienna, Austria
[9] Inst Super Ciencias & Tecnol Nucl, Havana, Cuba
[10] STUK, Radiat & Nucl Safety Author, FIN-00881 Helsinki, Finland
[11] Jozef Stefan Inst, Ljubljana 1000, Slovenia
[12] Czech Metrol Inst, Inspectorate Ionizing Radiat, CZ-10200 Prague 10, Czech Republic
[13] Max Planck Inst Kernphys, D-69029 Heidelberg, Germany
[14] CEN SCK, B-2400 Mol, Belgium
[15] Univ Bucharest, Dept Phys, RO-76900 Bucharest, Romania
[16] Norwegian Radiat Protect Author, N-1345 Osteras, Norway
[17] NRG RE, NL-6800 ET Arnhem, Netherlands
关键词
efficiency; germanium spectrometer; Monte Carlo simulation; geometry transfer; intercomparison; gamma-ray spectrometry;
D O I
10.1016/S0969-8043(01)00101-4
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The EUROMET project 428 examines efficiency transfer results for Ge gamma-ray spectrometers when the efficiency is known for a reference point source geometry. For this, different methods are used, such as Monte Carlo simulation or semi-empirical computation. The exercise compares the application of these methods to the same selected experimental cases to determine the usage limitations versus the requested accuracy. For carefully examining these results and trying to derive information for improving the computation codes, this study was limited to a few simple cases. The first part concerns the simplest case of geometry transfer, i.e., using point sources for 3 source-to-detect or distances: 2, 5 and 20 cm; the second part deals with transfer from point source geometry to cylindrical geometry with three different matrices. The general conclusion is that the deviations between the computed results and the measured efficiencies are mostly within 10%, The quality of the results is rather inhomogeneous and shows that these codes cannot be used directly for metrological purposes. However, most of them are operational for routine measurements when efficiency uncertainties of 5-10% can be sufficient. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:493 / 503
页数:11
相关论文
共 50 条
  • [31] Efficiency of a gamma-ray counter
    Sizoo, GJ
    Willemsen, H
    PHYSICA, 1938, 5 : 105 - 110
  • [32] INSTRUMENTAL METHODS OF GAMMA-RAY SPECTROMETRY
    CONNALLY, RE
    ANALYTICAL CHEMISTRY, 1956, 28 (12) : 1847 - 1853
  • [33] GAMMA-RAY SPECTROMETRY IN CENTRAL MOROCCO
    DEMNATI, A
    NAUDY, H
    GEOPHYSICS, 1975, 40 (02) : 331 - 343
  • [34] GAMMA-RAY SPECTROMETRY OF HOT PLASMAS
    Chugunov, I. N.
    Kiptily, V. G.
    Shevelev, A. E.
    Gin, D. B.
    FUSION SCIENCE AND TECHNOLOGY, 2011, 59 (1T) : 176 - 179
  • [35] Time resolved gamma-ray spectrometry
    Szentmiklosi, L.
    Belgya, T.
    Molnar, G. L.
    Revay, Zs.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 271 (02) : 439 - 445
  • [36] BACKGROUND ESTIMATION FOR GAMMA-RAY SPECTROMETRY
    BURGESS, DD
    TERVO, RJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 214 (2-3): : 431 - 434
  • [37] LIMITS OF MEASUREMENT IN GAMMA-RAY SPECTROMETRY
    IONESCU, C
    STUDII SI CERCETARI DE FIZICA, 1973, 25 (05): : 583 - 594
  • [38] A NEW SHIELD FOR GAMMA-RAY SPECTROMETRY
    BRAR, SS
    NELSON, DM
    GUSTAFSON, PF
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1967, 18 (04): : 261 - +
  • [39] GAMMA-RAY SPECTROMETRY IN CENTRAL MOROCCO
    SAMPAIO, ES
    GEOPHYSICS, 1976, 41 (03) : 542 - 542
  • [40] Time resolved gamma-ray spectrometry
    L. Szentmiklósi
    T. Belgya
    G. L. Molnár
    Zs. Révay
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 271 : 439 - 445