An investigation of effect of rigid and nonrigid connector designs on implant as pier abutment in implant tooth-supported fixed dental prosthesis with three-dimensional finite element analysis: An In vitro study

被引:0
|
作者
Kumar, S. Manoj [1 ]
Jei, J. Brintha [1 ]
Krishnan, Murugesan [1 ]
机构
[1] Sri Ramaswamy Mem Dent Coll, Dept Prosthodont & Crown & Bridge, Chennai, Tamil Nadu, India
关键词
Finite element analysis; implant pier abutment; non-rigid connector; rigid connector; PHOTOELASTIC STRESS-ANALYSIS; PARTIAL DENTURES; BONE;
D O I
10.4103/aihb.aihb_55_21
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction: The effect and stress distribution of rigid and non-rigid connectors were evaluated on a 5-unit fixed partial denture (FPD) with an implant as pier abutment by finite element analysis. Materials and Methods: A three-dimensional (3D) computed tomography with Digital imaging and communications in medicine (DICOM) format output was made for a patient with the implant in the second pre-molar region of the maxilla and missing the first pre-molar and first molar. In the obtained 3D finite element method (FEM) model, the implant in the second pre-molar region acts as a pier abutment. The canine and second molar served as terminal natural teeth abutments. By using CATIA V.05, the features of the implant in the second pre-molar region of 13 mm length and 3.75-mm diameter and 5 unit FPD tooth implant-supported prosthesis with rigid and non-rigid connector FEM models were made with a static vertical occlusal load of 250N. The areas and locations of maximum and minimum concentration of stress were analysed using Von Mises stress values for all the models at 10 Mpa. Results: The analysis of the von mishes stress values exposed the maximum stress concentrations at the load areas of all models. For all models, the highest stress values were located at connectors and cervical regions of abutment teeth, especially at the pier abutment. Conclusion: The area of maximum stress concentration at the pier abutment was decreased using the non-rigid connector at the mesial surface of the pier abutment.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 50 条
  • [41] Influence of Connector Design on Displacement and Micromotion in Tooth-Implant Fixed Partial Dentures Using Different Lengths and Diameters: A Three-Dimensional Finite Element Study
    Mously, Hisham A.
    Naguib, Ghada H.
    Hashem, Abou Bakr Hossam
    Abougazia, Ahmed O.
    Binmahfooz, Abdulelah M.
    Hamed, Mohamed T.
    MATERIALS, 2024, 17 (17)
  • [42] Effect of lubricant on the reliability of dental implant abutment screw joint: An in vitro laboratory and three-dimension finite element analysis
    Wu, Tingting
    Fan, Hongyi
    Ma, Ruiyang
    Chen, Hongyu
    Li, Zhi
    Yu, Haiyang
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 75 : 297 - 304
  • [43] Effects of Daily Mastication on Bone Remodeling With Implant-Tooth-Supported Fixed Partial Prosthesis: A Finite Element Study
    Zhang, Guangming
    Zhang, Yonghong
    Fu, Xiaoming
    Zhang, Xiaonan
    IEEE ACCESS, 2019, 7 : 33851 - 33858
  • [44] Three-Dimensional Finite Element Analysis on Stress Distribution of Internal Implant-Abutment Engagement Features
    Cho, Sung-Yong
    Huh, Yun-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : 319 - 327
  • [45] Three-dimensional finite element analysis of two angled narrow-diameter implant designs for an all-on-4 prosthesis
    Moreira de Melo, Edmundo Jose, Jr.
    Francischone, Carlos Eduardo
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (04): : 477 - 484
  • [46] Finite Element Analysis: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework
    Muhsin S.A.
    Mohammed E.K.
    Bander K.
    Journal of Long-Term Effects of Medical Implants, 2024, 34 (04) : 33 - 47
  • [47] Implant-Supported Fixed Partial Prostheses With Different Prosthetic Materials: A Three-Dimensional Finite Element Stress Analysis
    Arinc, Hakan
    IMPLANT DENTISTRY, 2018, 27 (03) : 303 - 310
  • [48] Three-dimensional finite element analysis of extra short implants focusing on implant designs and materials
    Araki, Haruka
    Nakano, Tamaki
    Ono, Shinji
    Yatani, Hirofumi
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [49] Three-dimensional finite element analysis of extra short implants focusing on implant designs and materials
    Haruka Araki
    Tamaki Nakano
    Shinji Ono
    Hirofumi Yatani
    International Journal of Implant Dentistry, 6
  • [50] A Finite Element Analysis of a Tooth-Supported 3D-Printed Surgical Guide without Metallic Sleeves for Dental Implant Insertion
    Ghionea, Ionut Gabriel
    Vatamanu, Oana Elena Burlacu
    Cristescu, Ana Maria
    David, Mihai
    Stancu, Izabela Cristina
    Butnarasu, Cristian
    Cristache, Corina Marilena
    APPLIED SCIENCES-BASEL, 2023, 13 (17):