Dynamic X-ray direct conversion detector using a CdTe polycrystalline layer coupled to a CMOS readout chip

被引:5
|
作者
Arques, Marc [2 ]
Renet, Sebastien [2 ]
Brambilla, Andrea [2 ]
Feuillet, Guy [2 ]
Gasse, Adrien [2 ]
Billon-Pierron, Nicolas [2 ]
Jolliot, Muriel [2 ]
Mathieu, Lydie [2 ]
Rohr, Pierre [1 ]
机构
[1] TRIXELL, F-38430 Moirans, France
[2] CEA LETI MINATEC, F-38054 Grenoble, France
关键词
CdTe; Close space sublimation; CMOS; X-ray;
D O I
10.1016/j.nima.2010.06.120
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A direct detection X-ray imager is presented. It uses polycrystalline cadmium telluride (CdTe) grown by close space sublimation technique for the X-ray photoconductor. A 15 mm x 15 mm CdTe layer is connected to a 200 x 200 pixel readout CMOS by indium bumping. X-ray performance at 16 frames/s rate is measured. In particular a readout noise of 0.5 X-ray, an MTF of 50% at 4 lp/mm and a DQE of 20% at 4 lp/mm are obtained. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:S55 / S58
页数:4
相关论文
共 50 条
  • [1] Fluoroscopic x-ray demonstrator using a CdTe polycrystalline layer coupled to a CMOS readout chip
    Arques, M.
    Renet, S.
    Brambilla, A.
    Feuillet, G.
    Gasse, A.
    Billon-Pierron, N.
    Jolliot, M.
    Mathieu, L.
    Rohr, P.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [2] CMOS direct conversion X-ray detector coupled with fluorinated liquid
    ShiHua Liu
    ChaoSong Gao
    Xin Zhang
    XiangMing Sun
    Meng Wu
    ZhiHui Han
    Tong Wan
    YongShuai Ge
    Nuclear Science and Techniques, 2025, 36 (01) : 5 - 14
  • [3] Cmos direct conversion X-ray detector coupled with fluorinated liquid
    Liu, Shi-Hua
    Gao, Chao-Song
    Zhang, Xin
    Sun, Xiang-Ming
    Wu, Meng
    Han, Zhi-Hui
    Wan, Tong
    Ge, Yong-Shuai
    NUCLEAR SCIENCE AND TECHNIQUES, 2025, 36 (01)
  • [4] Characterization of a Pixelated CdTe X-Ray Detector Using the Timepix Photon-Counting Readout Chip
    Ruat, Marie
    Ponchut, Cyril
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 2392 - 2401
  • [5] Characterization of a X-ray pixellated CdTe detector with TIMEPIX photon-counting readout chip
    Ruat, Marie
    Ponchut, Cyril
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4799 - 4803
  • [6] Readout QDC for CdTe x-ray imager using direct charge treatment
    Takagi, Katsuyuki
    Takagi, Toshiyuki
    Terao, Tsuyoshi
    Koike, Akifumi
    Aoki, Toru
    IMAGE SENSING TECHNOLOGIES: MATERIALS, DEVICES, SYSTEMS, AND APPLICATIONS V, 2018, 10656
  • [7] Direct deposition of polycrystalline CdTe films on the Medipix readout chip and evaluation of layer quality and imaging results
    Vogt, A.
    Schuett, S.
    Fischer, F.
    Disch, C.
    Procz, S.
    Lu, Y.
    Fiederle, M.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [8] Mapping the X-ray response of a CdTe sensor with small pixels using an X-ray microbeam and a single photon processing readout chip
    Frojdh, Erik
    Frojdh, Christer
    Norlin, Borje
    Thungstrom, Goran
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XIII, 2011, 8142
  • [9] PbO as direct conversion X-ray detector material
    Simon, M
    Ford, RA
    Franklin, AR
    Grabowski, SP
    Menser, B
    Much, G
    Nascetti, A
    Overdick, M
    Powell, MJ
    Wiechert, DU
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 188 - 199
  • [10] CdTe layer structures for X-ray and gamma-ray detection directly grown on the Medipix readout-chip by MBE
    Vogt, A.
    Schuett, S.
    Frei, K.
    Fiederle, M.
    JOURNAL OF CRYSTAL GROWTH, 2017, 477 : 114 - 117