Minimally Invasive Surgery by Angular Stability Systems in Proximal Tibia Fractures - Biomechanical Characteristics and Preliminary Results

被引:1
|
作者
Sirbu, P. D. [1 ]
Carata, E. [2 ]
Petreus, T. [1 ]
Munteanu, F. [1 ]
Popescu, C. [3 ]
Asaftei, R. [1 ]
Botez, P. [1 ]
机构
[1] Gr T Popa Univ Med & Pharm Iasi, 16 Univ, Iasi, Romania
[2] Gh Asachi Tech Univ, Iasi, Romania
[3] Nicolae Oblu Emergency Clin Hosp, Iasi, Romania
关键词
LISS-PLT; proximal tibia fractures; internal fixator; aiming device; angular stability;
D O I
10.1007/978-3-642-04292-8_91
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Complex fractures of the proximal tibia are difficult to treat. Minimally invasive plate osteosynthesis (MIPO) has determined the result improvement while the angular stability plate type Less Invasive Stabilization System - proximal lateral tibia (LISS-PLT) or Locked Compression plate (LCP-PLT) were specially created for this kind of fractures. The purpose of this study was to emphasize the design and biomechanical characteristics of these systems as well as to evaluate the results following the treatment of the complex fractures on the proximal tibia by MIPO with these plates with angular stability. The authors emphasize the design of the plate, the concept of the internal fixator and the importance of the aiming device for percutaneous insertion. There were investigated 8 fractures of the proximal tibia in 8 patients, with a mean age of 39.5 years. Fractures were classified according to AO/ASIF in 2 type A3, 2 type C1, 2 type C2 and 2 type C3). There were three open fractures (1 type I and 2 type II) according to Gustilo. In all 8 cases we have performed minimally invasive plate osteosynthesis, using a LISS-PLT system in 5 cases or a LCP-PLT in 3 cases. All fractures healed after a mean time of 13 weeks and the knee mobility was considered as good (mean flexion of 105 degrees). Due to major biomechanical and biological advantages, the authors consider that, despite the high prices, the internal fixator type LISS-PLT or LCP-PLT represent the ideal implants for the complex fractures of proximal tibia.
引用
收藏
页码:413 / +
页数:2
相关论文
共 50 条
  • [31] Minimally invasive plate osteosynthesis in proximal humeral fractures: one-year results of a prospective multicenter study
    Francesco Falez
    Matteo Papalia
    Alessandro Greco
    Antonio Teti
    Fabio Favetti
    Gabriele Panegrossi
    Filippo Casella
    Stefano Necozione
    International Orthopaedics, 2016, 40 : 579 - 585
  • [32] Preliminary results of an early vs delayed timing of surgery in the management of proximal femur fragility fractures
    Matassi, Fabrizio
    Carulli, Christian
    Munz, Giovanni
    Lualdi, Carlotta
    Civinini, Roberto
    Innocenti, Massimo
    CLINICAL CASES IN MINERAL AND BONE METABOLISM, 2015, 12 (01) : 11 - 17
  • [33] Mid-Term Results of Minimally Invasive Plate Osteosynthesis and Circular External Fixation in the Treatment of Complex Distal Tibia Fractures
    Imren, Yunus
    Desteli, Engin Eren
    Erdil, Mehmet
    Ceylan, Hasan Huseyin
    Tuncay, Ibrahim
    Sen, Cengiz
    JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2017, 107 (01) : 3 - 10
  • [34] Minimally invasive and open surgical treatment of proximal tibia fractures using a polyaxial locking plate system: a prospective multi-centre study
    Joeckel, Jens A.
    Erhardt, Johannes
    Vincenti, Miscia
    Reissig, Joerg
    Hoffmann, Reinhard
    Husain, Baher
    Taeger, Gert
    Partenheimer, Axel
    Lill, Helmut
    Gebhard, Florian
    Roederer, Goetz
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (04) : 701 - 708
  • [35] Minilaparotomy abdominal aortic aneurysm repair in the era of minimally invasive vascular surgery: preliminary results
    Bakoyiannis, Chris N.
    Tsekouras, Nikolaos S.
    Georgopoulos, Sotiris E.
    Skrapari, Ioanna C.
    Economopoulos, Konstantinos P.
    Tsigris, Christos
    Bastounis, Elias A.
    ANZ JOURNAL OF SURGERY, 2009, 79 (11) : 829 - 835
  • [36] Tactile Feedback for Artery Detection in Minimally Invasive Robotic Surgery - Preliminary Results of a New Approach
    Kuebler, B.
    Gruber, R.
    Joppek, Ch.
    Port, J.
    Passig, G.
    Nagel, J. H.
    Hirzinger, G.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 6, 2009, 25 : 299 - +
  • [37] Minimally invasive and open surgical treatment of proximal tibia fractures using a polyaxial locking plate system: a prospective multi-centre study
    Jens A. Jöckel
    Johannes Erhardt
    Miscia Vincenti
    Jörg Reissig
    Reinhard Hoffmann
    Baher Husain
    Gert Täger
    Axel Partenheimer
    Helmut Lill
    Florian Gebhard
    Götz Röderer
    International Orthopaedics, 2013, 37 : 701 - 708
  • [38] Preliminary evaluation of biomechanical modeling of lung deflation during minimally invasive surgery using pneumothorax computed tomography scans
    Lesage, Anne-Cecile
    Rajaram, Ravi
    Tam, Alda
    Rigaud, Bastien
    Brock, Kristy
    Rice, David
    Cazoulat, Guillaume
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (22):
  • [39] Vesselplasty: A New Minimally Invasive Approach to Treat Pathological Vertebral Fractures in Selected Tumor Patients - Preliminary Results
    Klingler, J. -H.
    Sircar, R.
    Deininger, M. H.
    Scheiwe, C.
    Kogias, E.
    Hubbe, U.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2013, 185 (04): : 340 - 350
  • [40] SuperPATH Minimally Invasive Approach to Total Hip Arthroplasty of Femoral Neck Fractures in the Elderly: Preliminary Clinical Results
    Wang, Xiao-dong
    Lan, Hai
    Hu, Zheng-xia
    Li, Kai-nan
    Wang, Zheng-hao
    Luo, Jin
    Long, Xu-dong
    ORTHOPAEDIC SURGERY, 2020, 12 (01) : 74 - 85