Performance analysis of counter-flow regenerative heat and mass exchanger for indirect evaporative cooling based on data-driven model

被引:37
|
作者
Zhu, Guangya [1 ]
Chow, Tin-Tai [1 ]
Lee, C. K. [1 ]
机构
[1] City Univ Hong Kong, Div Bldg Sci & Technol, Bldg Energy & Environm Technol Res Unit, Hong Kong, Hong Kong, Peoples R China
关键词
Maisotsenko cycle; Regenerative evaporative cooler; Data-driven model; Performance prediction; AIR-CONDITIONING SYSTEMS; MAISOTSENKO CYCLE HEAT; NUMERICAL-ANALYSIS; COOLER; DESIGN; CONFIGURATION; OPTIMIZATION;
D O I
10.1016/j.enbuild.2017.09.053
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigated the performance of a regenerative heat and mass exchanger (RHMX) for indirect evaporative cooling. A numerical model for RHMX was developed and validated with experimental data from the literature. Then, a data-driven model based on artificial neural" network (ANN) algorithm was presented which was derived from the simulation results generated from the numerical model. The comparison between ANN prediction and experiment data showed good prediction accuracy. The average prediction error between the predicted and tested data was around 4% based on the air temperature change across the dry channel. With the data-driven model, parametric analyses were made to investigate the performance of the RHMX under different operating conditions. Finally, a design optimisation of the extraction air ratio was conducted under different ambient conditions. It was found that the optimal extraction air ratio decreased with the ambient temperature and/or relative humidity which ranged from 0.3 to 0.36. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:503 / 512
页数:10
相关论文
共 50 条
  • [41] Development and experimental analysis of a novel dual-mode counter-flow evaporative cooling device
    Kashyap, Sarvesh
    Sarkar, Jahar
    Kumar, Amitesh
    BUILDING AND ENVIRONMENT, 2021, 205
  • [42] Application of combined direct and indirect adaptive control algorithms for temperature control of counter-flow heat exchanger
    Saxena, SC
    Verma, HK
    Chile, RH
    IETE JOURNAL OF RESEARCH, 2000, 46 (04) : 265 - 275
  • [43] Optimization criteria for the performance of heat and mass transfer in indirect evaporative cooling systems
    Yuan Fang
    Chen Qun
    CHINESE SCIENCE BULLETIN, 2012, 57 (06): : 687 - 693
  • [44] Optimization criteria for the performance of heat and mass transfer in indirect evaporative cooling systems
    YUAN Fang & CHEN Qun Key Laboratory for Thermal Science and Power Engineering of Ministry of Education
    Chinese Science Bulletin, 2012, 57 (06) : 690 - 696
  • [46] Comprehensive coupling model of counter-flow wet cooling tower and its thermal performance analysis
    Yu, J. H.
    Qu, Z. G.
    Zhang, J. F.
    Hu, S. J.
    Guan, J.
    ENERGY, 2022, 238
  • [47] Comparative study on performance of counter-flow dew-point indirect evaporative cooling systems via a more realistic and experimentally validated three-dimensional model
    Wan, Yangda
    Xue, Tinghui
    Huang, Zhifeng
    Soh, Alexandera
    Liu, Haibo
    Chua, Kian Jon
    JOURNAL OF BUILDING ENGINEERING, 2024, 82
  • [48] Energy-based visualisation of a counter-flow heat exchanger for the purpose of fault identification
    Uren, Kenneth R.
    van Schoor, George
    IFAC PAPERSONLINE, 2016, 49 (07): : 19 - 24
  • [49] Performance characterization and optimization of counter-flow dew point indirect evaporative cooler through response surface methodology
    Kousar, Rubeena
    Ali, Muzaffar
    Amja, Muhammad Kamal
    Sheikh, Nadeem Ahmed
    Ahmad, Waqas
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2021, 235 (07) : 1789 - 1805
  • [50] PERFORMANCE EVALUATION OF COUNTER-FLOW WET COOLING TOWERS USING EXERGETIC ANALYSIS
    Ataei, A.
    Panjeshahi, M. H.
    Gharaie, M.
    TRANSACTIONS OF THE CANADIAN SOCIETY FOR MECHANICAL ENGINEERING, 2008, 32 (3-4) : 499 - 511