Closed Sinusoid Trajectory for C-Arm CT Imaging

被引:1
|
作者
Yang, Haiquan [1 ]
Li, Meihua [1 ]
Koizumi, Kazuhito [1 ]
Kudo, Hiroyuki [2 ]
机构
[1] Uni Hite Syst Corp, Dept Res & Dev, Kanagawa, Japan
[2] Univ Tsukuba, Grad Sch Syst & Informat Engn, Tsukuba, Ibaraki 305, Japan
关键词
computed tomography; cone-beam reconstruction; closed sinusoid; C-arm;
D O I
10.1109/NSSMIC.2006.353750
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we investigate cone-beam reconstruction for C-arm CT imaging using a closed sinusoid trajectory, which was firstly studied in [17] and can be considered a generalization of a saddle trajectory [7]. Inspired by the work in [10] and [13], we propose an exact shift-invariant filtered backprojection (FBP) reconstruction algorithm when the scanning trajectory is a closed sinusoid, or a perturbed closed sinusoid. We determine the filtering lines on the detector plane and give the steps to implement the algorithm for the planar detector geometry in a C-arm system. We also give two view independent reconstruction formulae for this geometry, both of which do not involve the view differencing operation and improve the reconstructed images by reducing discretization and sampling errors. The proposed algorithm is tested by simulation studies.
引用
收藏
页码:3480 / 3484
页数:5
相关论文
共 50 条
  • [31] System to Guide Transcatheter Aortic Valve Implantations Based on Interventional C-Arm CT Imaging
    John, Matthias
    Liao, Rui
    Zheng, Yefeng
    Noettling, Alois
    Boese, Jan
    Kirschstein, Uwe
    Kempfert, Joerg
    Walther, Thomas
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT I, 2010, 6361 : 375 - +
  • [32] Novel C-arm based cone-beam CT using a source trajectory of two concentric arcs
    Zambelli, Joseph
    Nett, Brian E.
    Leng, Shuai
    Riddell, Cyril
    Belanger, Barry
    Chen, Guang-Hong
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [33] Short-roll C-arm computed tomography (C-arm CT) scans to guide transcatheter aortic valve replacements
    Bracken, John
    Kim, Michael S.
    Messenger, John C.
    Cleveland, Joseph
    Fullerton, David
    Eshuis, Peter
    Grass, Michael
    Carroll, John
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B194 - B194
  • [34] Pulmonary Balloon Angioplasty under C-arm CT Guidance
    Graewert, Stephanie
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2020, 192 (02): : 136 - 136
  • [35] The isocentric C-arm
    Meier, R.
    Geerling, J.
    Huefner, T.
    Kfuri, M.
    Krettek, C.
    UNFALLCHIRURG, 2011, 114 (07): : 587 - 590
  • [36] Pulmonary Balloon Angioplasty under C-arm CT Guidance
    Graewert, Stephanie
    PNEUMOLOGIE, 2020, 74 (03):
  • [37] C-Arm Cone-Beam CT: Principles and Applications
    Siewerdsen, J.
    Chen, G.
    MEDICAL PHYSICS, 2009, 36 (06) : 2716 - +
  • [38] C-ARM FLUOROSCOPY
    COHEN, MD
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (03) : 646 - 647
  • [39] Cardiac C-Arm CT: A Unified Framework for Motion Estimation and Dynamic CT
    Pruemmer, Marcus
    Hornegger, Joachim
    Lauritsch, Guenter
    Wigstroem, Lars
    Girard-Hughes, Erin
    Fahrig, Rebecca
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (11) : 1836 - 1849
  • [40] Image Reconstruction with Perturbed Trajectories in a C-Arm CT System
    XU Ming
    PU Fang
    LI Shu-yu
    NIU Hai-jun
    FAN Yu-bo
    LI De-yu
    ChineseJournalofBiomedicalEngineering, 2015, 24 (03) : 120 - 127