Derivation of sonograph quality parameters by the use of point spread function analysis

被引:3
|
作者
Dolezal, L. [1 ]
Mazura, J. [1 ]
Tesarik, J. [1 ]
Kolarova, H. [1 ]
Korpas, D. [1 ]
Binder, S. [1 ]
Halek, J. [1 ]
机构
[1] Palacky Univ, Fac Med, Inst Med Biophys, CR-77147 Olomouc, Czech Republic
关键词
ultrasonography; point spread function; quality; imaging;
D O I
10.33549/physiolres.931304
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A measuring system evaluating a Point Spread Function generated in an ultrasonographic image by scanning a spherical target was developed. The target is moved in measuring bath filled by water over scanned volume via 3D computer controlled positioning system. A video signal obtained is converted to digital form and analyzed by original software to derive various objective parameters of the imager as follows: Focal areas in both the azimuth and the elevation directions, Ultrasound scanning lines visualisation, Manufacturer preloaded TGC, Width of the scanning plane, Side lobe levels and Amplification uniformity in the azimuth direction. The method was verified by testing 18 different equipments in 282 measurements. Samples of particular measurement results in form of graphical outputs are included. Medical and physiological impacts of this approach are discussed.
引用
收藏
页码:S69 / S76
页数:8
相关论文
共 50 条
  • [21] Estimation of sensor point spread function by spatial subpixel analysis
    Kaiser, G.
    Schneider, W.
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2008, 29 (07) : 2137 - 2155
  • [22] Point spread function analysis with saturable and reverse saturable scattering
    Lee, Hsuan
    Oketani, Ryosuke
    Huang, Yen-Ta
    Li, Kuan-Yu
    Yonemaru, Yasuo
    Yamanaka, Masahito
    Kawata, Satoshi
    Fujita, Katsumasa
    Chu, Shi-Wei
    OPTICS EXPRESS, 2014, 22 (21): : 26016 - 26022
  • [23] USE OF POINT SPREAD AND BEAM SPREAD FUNCTIONS FOR ANALYSIS OF IMAGING-SYSTEMS IN WATER
    MERTENS, LE
    REPLOGLE, FS
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1977, 67 (08) : 1105 - 1117
  • [24] EXPERIMENTAL DERIVATION OF POINT-SPREAD FUNCTIONS FROM LINE-SPREAD RECORDINGS
    MACINTYRE, WJ
    HOUSER, TS
    JOURNAL OF NUCLEAR MEDICINE, 1971, 12 (06) : 379 - +
  • [25] Improvement in PET/CT Image Quality with a Combination of Point-Spread Function and Time-of-Flight in Relation to Reconstruction Parameters
    Akamatsu, Go
    Ishikawa, Kaori
    Mitsumoto, Katsuhiko
    Taniguchi, Takafumi
    Ohya, Nobuyoshi
    Baba, Shingo
    Abe, Koichiro
    Sasaki, Masayuki
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (11) : 1716 - 1722
  • [26] Bayesian estimation of regularization and point spread function parameters for Wiener-Hunt deconvolution
    Orieux, Francois
    Giovannelli, Jean-Francois
    Rodet, Thomas
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2010, 27 (07) : 1593 - 1607
  • [27] Phase Retrieval of a Point Spread Function
    Chimitt, Nicholas
    Almuallem, Ali
    Chan, Stanley H.
    UNCONVENTIONAL IMAGING, SENSING, AND ADAPTIVE OPTICS 2024, 2024, 13149
  • [28] MEASUREMENT OF THE POINT SPREAD FUNCTION IN THE OCEAN
    VOSS, KJ
    CHAPIN, AL
    APPLIED OPTICS, 1990, 29 (25): : 3638 - 3642
  • [29] The Spectro point spread function for GAIA
    Fabricius, C
    Lindegren, L
    ASTROPHYSICS AND SPACE SCIENCE, 2002, 280 (1-2) : 51 - 56
  • [30] The point spread function of spiral CT
    Schwarzband, G
    Kiryati, N
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (22): : 5307 - 5322