摘要
Four thick-walled 1008 mm (39.7 in.) long cylindrical specimens with an inside diameter of 304.8 mm (12 in.), a wall thickness of 76.2 mm (3 in.), and a monolithically cast 250 mm (9.8 in.) long flange at either end were fabricated. For three of the specimens, a spiral post-tensioning system consisting of four clockwise and four counterclockwise outside wrapping strands was used. The fourth specimen had eight post-tensioned straight strands. Specimens were fabricated using high-performance, self-consolidating concrete and 12.5 mm (0.5 in.) post-tensioning tendons. Each specimen was supported at the ends and point loaded at the midspan. Spiral specimens were post-tensioned to 25, 50, and 75% of strand capacity, whereas the specimen with straight strands was post-tensioned to 50% strand capacity. The spiral post-tensioning system increased ultimate capacity by 45% when compared with the specimen having longitudinally aligned strands.
引用
收藏
页码:563 / 571
页数:9
相关论文
共 50 条
  • [41] The application of external post-tensioning system to a damage masonry arch
    Zampieri, Paolo
    Piazzon, Riccardo
    Ferroni, Riccardo
    Pellegrino, Carlo
    XIX ANIDIS CONFERENCE, SEISMIC ENGINEERING IN ITALY, 2023, 44 : 605 - 609
  • [42] POST-TENSIONING APPLICATIONS FOR BRIDGE REHABILITATION
    LAMBERSON, EA
    CONSTRUCTION CONTRACTING, 1983, 65 (02): : 24 - 24
  • [43] GROUT FOR POST-TENSIONING DUCTS - DISCUSSION
    SCHUPACK, M
    ACI MATERIALS JOURNAL, 1989, 86 (03) : 328 - 329
  • [44] DEMOLITION POST-TENSIONING STILL BOGEYMAN
    不详
    CONCRETE, 1973, 7 (02): : 42 - 42
  • [45] HOW DOES SHRINKAGE-COMPENSATING CEMENT CONCRETE HELP POST-TENSIONING
    不详
    CONCRETE CONSTRUCTION, 1983, 28 (04): : 331 - 333
  • [46] Specifications for Unbonded Post-Tensioning Tendons
    1600, American Concrete Institute (38):
  • [47] PRECAST CONCRETE AND CAST-IN-PLACE CONCRETE WITH POST-TENSIONING SPEEDS PARKING STRUCTURE CONSTRUCTION
    不详
    JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1973, 18 (03): : 98 - 99
  • [48] Identifying voids in plastic ducts in post-tensioning prestressed concrete members by resonant frequency of impact-echo, SIBIE and tomography
    Muldoon, R.
    Chalker, A.
    Forde, M. C.
    Ohtsu, M.
    Kunisue, F.
    CONSTRUCTION AND BUILDING MATERIALS, 2007, 21 (03) : 527 - 537
  • [49] Post-tensioning cuts steel bridge costs
    Spaans, Leo
    Modern Steel Construction, 1994, 34 (09): : 38 - 43
  • [50] FRP post-tensioning of laminated timber bridges
    Dagher, HJ
    Schmidt, AL
    Abdel-Magid, B
    Iyer, S
    EVOLVING TECHNOLOGIES FOR THE COMPETITIVE EDGE, BOOKS 1 AND 2, 1997, 42 : 933 - 938