Multi-wavelength photoplethysmography method for skin arterial pulse extraction

被引:79
|
作者
Liu, Jing [1 ]
Yan, Bryan Ping-Yen [2 ]
Dai, Wen-Xuan [1 ]
Ding, Xiao-Rong [1 ]
Zhang, Yuan-Ting [1 ,3 ]
Zhao, Ni [1 ]
机构
[1] Chinese Univ Hong Kong, Dept Elect Engn, Shatin, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Prince Wales Hosp, Dept Med & Therapeut, Div Cardiol, Shatin, Hong Kong, Peoples R China
[3] Chinese Acad Sci, China Key Lab Hlth Informat, Shenzhen, Guangdong, Peoples R China
来源
BIOMEDICAL OPTICS EXPRESS | 2016年 / 7卷 / 10期
关键词
BEER-LAMBERT LAW; BLOOD-PRESSURE; TIME;
D O I
10.1364/BOE.7.004313
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, we present a multi-wavelength (MW) PPG method exploiting the wavelength dependence of light penetration in skin tissue to provide depth resolution of skin blood pulsation. The MW PPG system requires two to three light sources in different wavelengths and extracts the arterial blood pulsation through a multi-wavelength multi-layer light-skin interaction model, which removes the capillary pulsation (determined from the short-wavelength PPG signal) from the long-wavelength PPG signal using absorption weighting factors that are quasi-analytically calibrated. The extracted pulsations are used to calculate blood pressure (BP) through pulse transit time (PTT), and the results are compared with those obtained from the single wavelength PPG method. The comparative study is clinically performed on 20 subjects including 10 patients diagnosed with cardiovascular diseases and 10 healthy subjects. The result demonstrates that the MW PPG method significantly improves the measurement accuracy of systolic BP (SBP), reducing the mean absolute difference between the reference and the estimated SBP values from 5.7 mmHg (for single-wavelength PPG) to 2.9 mmHg (for three-wavelength PPG). (C) 2016 Optical Society of America
引用
收藏
页码:4313 / 4326
页数:14
相关论文
共 50 条
  • [31] Robust autofocusing method for multi-wavelength lensless imaging
    Liu, Jian
    Zhao, Yixuan
    Guo, Cheng
    Zhao, Weisong
    Zhang, Yutian
    Guo, Changliang
    Li, Haoyu
    OPTICS EXPRESS, 2019, 27 (17) : 23814 - 23829
  • [32] Development of multi-wavelength spectral-correction method
    Gao, HW
    CHINESE CHEMICAL LETTERS, 2000, 11 (10) : 893 - 894
  • [33] Method of nanometer measurement using multi-wavelength interferometry
    Cheng, Xiaohui
    Li, Dacheng
    Zhao, Yang
    Guangxue Jishu/Optical Technique, 2000, 26 (04): : 313 - 315
  • [34] New method for the design of multi-wavelength optical head
    Liu, HT
    Pang, L
    Yan, YB
    DIFFRACTIVE AND HOLOGRAPHIC TECHNOLOGIES FOR INTEGRATED PHOTONIC SYSTEMS, 2001, 4291 : 165 - 172
  • [35] Multi-wavelength diffractive neural network with the weighting method
    Feng, Jianan
    Chen, Hang
    Yang, Dahai
    Hao, Junbo
    Lin, Jie
    Jin, Peng
    OPTICS EXPRESS, 2023, 31 (20) : 33113 - 33122
  • [36] Development of Multi-Wavelength Spectral-Correction Method
    Hong Wen GAO (School of Chemistry and Chemical Engineering
    ChineseChemicalLetters, 2000, (10) : 893 - 894
  • [37] Measurement of Multi-Wavelength Pulse Oxygen Saturation Based on Dynamic Spectroscopy
    Wang Xiao-fei
    Zhao Wen-jun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (05) : 1323 - 1326
  • [38] Highly flexible Nyquist pulse generation based on multi-wavelength control
    Zhang, Bingjian
    Wu, Kan
    Zhang, Tianzhu
    Liu, Siqi
    Chen, Jianping
    CHINESE OPTICS LETTERS, 2020, 18 (07)
  • [39] Multi-Wavelength Microring-based Optical Pulse Train Generator
    Wang, Shang
    wu, Hui
    2012 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2012,
  • [40] A tunable repetition rate multiplier for multi-wavelength optical pulse trains
    Wang, Mingqing
    Lou, Shuqin
    OPTICS COMMUNICATIONS, 2021, 480