Optimization of Overall Network of Water-Using and Treatment Units

被引:0
|
作者
Tudor, Raluca [1 ]
Lavric, Vasile [1 ]
机构
[1] Univ Politehn Bucuresti, Dept Chem Engn, Polizu 1-7, RO-011061 Bucharest, Romania
关键词
integrated network; fresh water minimization; contaminant mean availability; network reuse index; genetic algorithms; GENETIC ALGORITHM; REGENERATION; TOPOLOGY; DESIGN;
D O I
暂无
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The concept of process integration has gained more and more attention in the last years due to its beneficial results in the framework of freshwater minimization, costs reduction and environmental impact diminution. The optimization of an integrated water-using (WU) and treatment units (TU) network is addressed in this paper, by targeting for maximum treated water reuse as a considerably better alternative to fresh water consumption. The mathematical model of the integrated water network (IWN) is based upon total and contaminant species balances. They are written for each and every unit and are subject of restrictions of inlet and outlet contaminant concentrations. The optimization problem is carried via Genetic Algorithms. An industrial example was analyzed with respect to contaminants' mean availability and network reuse index to point out the benefits of integration.
引用
收藏
页码:913 / 918
页数:6
相关论文
共 50 条
  • [21] Retrofit of water network with optimization of existing regeneration units
    Tan, Yin Ling
    Manan, Zainuddin Abdul
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2006, 45 (22) : 7592 - 7602
  • [22] Design of optimal water-using networks with internal water mains
    Zheng, Xuesong
    Feng, Xiao
    Shen, Renjie
    Seider, Warren D.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2006, 45 (25) : 8413 - 8420
  • [23] Evolution of Water-Using Networks with Multiple Contaminants
    Li, Bao-Hong
    Chang, Chuei-Tin
    PRES 2011: 14TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1 AND 2, 2011, 25 : 599 - +
  • [24] Studies on the effect of non-isothermal mixing on water-using network's energy performance
    Luo Yiqing
    Mao Tingbi
    Luo Sucai
    Yuan Xigang
    COMPUTERS & CHEMICAL ENGINEERING, 2012, 36 : 140 - 148
  • [25] A superstructure model of water-using network synthesis with multiple contaminants for batch processes and its solution
    Yang, Xia
    Yue, Jincai
    Zheng, Shiqing
    11TH INTERNATIONAL SYMPOSIUM ON PROCESS SYSTEMS ENGINEERING, PTS A AND B, 2012, 31 : 510 - 514
  • [26] Optimal Design of an Integrated Discontinuous Water-Using Network Coordinating with a Central Continuous Regeneration Unit
    Liu, Yongzhong
    Li, Guanhua
    Wang, Le
    Zhang, Jinzhi
    Shams, Kayghobad
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2009, 48 (24) : 10924 - 10940
  • [27] Efficient water-using technologies and habits: A disaggregated analysis in the water sector
    Perez-Urdiales, Maria
    Angeles Garcia-Vallinas, Maria
    ECOLOGICAL ECONOMICS, 2016, 128 : 117 - 129
  • [28] Determinants of Water Connection Type and Ownership of Water-Using Appliances in Ireland
    Lyons, Sean
    O'Doherty, Joe
    Tol, Richard S. J.
    WATER RESOURCES MANAGEMENT, 2010, 24 (12) : 2853 - 2867
  • [29] Determinants of Water Connection Type and Ownership of Water-Using Appliances in Ireland
    Sean Lyons
    Joe O’Doherty
    Richard S. J. Tol
    Water Resources Management, 2010, 24 : 2853 - 2867
  • [30] Targeting of water-using networks involving regeneration with a graphical approach
    Xiao-Yan Fan
    Da-Long Xu
    Jian-Feng Zhu
    Zhi-Yong Liu
    Clean Technologies and Environmental Policy, 2016, 18 : 2087 - 2094