Upgrade of the Trigger System of the ATLAS Liquid Argon Calorimeters

被引:0
|
作者
Kanaya, N. [1 ]
机构
[1] Univ Tokyo, Int Ctr Particle Phys, Tokyo, Japan
关键词
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The ATLAS detector was designed and was built to study proton-proton collisions produced at the LHC at centre-of-mass energies up to 14 TeV and instantaneous luminosities up to 10(34) cm(-2) s(-1). The ATLAS Liquid Argon (LAr) calorimeters produce a total of 182,486 signals, which are digitized and processed by the front-end and back-end electronics for each triggered event. In addition, the front-end electronics sums analog signals to provide coarse-grained energy sums, called trigger towers, to the first-level trigger system, which is optimized for nominal LHC luminosities. In 2020, instantaneous luminosities of (2-3) 10(34) cm(-2) s(-1) are expected, far beyond that for which the detector was designed. In order to cope with the increased trigger rate, an improved spatial granularity of the trigger primitives is proposed, to improve the identification performance for trigger signatures at high background rejection rates. For these purposes, a new LAr Trigger Digitizer Board (LTDB) is being designed to receive higher granularity signals, digitize them on-detector and send them via fast optical links to a new digital processing system (DPS). The DPS applies digital filtering and identifies significant energy depositions in each trigger channel. The general concept of the upgraded LAr calorimeter trigger and expected performance as well as the various electronics components to be developed are described.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] The status of the construction and the performance of the ATLAS liquid argon electromagnetic calorimeters
    Lund-Jensen, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2181 - 2186
  • [32] LHC-ATLAS Phase-I upgrade: calibration and simulation of a new trigger readout system for the Liquid Argon calorimeter
    Tateno, G.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (05):
  • [33] The latency validation of the optical link for the ATLAS Liquid Argon Calorimeter Phase-I trigger upgrade
    Deng, B.
    Xiao, L.
    Zhao, X.
    Baker, E.
    Gong, D.
    Guo, D.
    He, H.
    Hou, S.
    Liu, C.
    Liu, T.
    Sun, Q.
    Thomas, J.
    Wang, J.
    Xiang, A. C.
    Yang, D.
    Ye, J.
    Zhou, W.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [34] The Phase-2 electronics upgrade of the ATLAS liquid argon calorimeter system
    Vachon, B.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [35] Upgrade of the readout electronics for the ATLAS Liquid Argon Calorimeter
    Carbone, A.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2025, 48 (03):
  • [36] A purity monitoring system for liquid argon calorimeters
    Adams, M
    Buchholz, P
    Dahlhoff, A
    Feiden, D
    Gärtner, V
    Grams, M
    Haarmann, M
    Hergesell, A
    Hölldorfer, F
    Ielapi, G
    Jakobs, K
    Jung, T
    Köpke, L
    Kuhnert, E
    Meder, D
    Schäfer, U
    Schmidt, A
    Schué, Y
    Schwarz, C
    Walkowiak, W
    Weber, D
    Wilke, D
    Zeitnitz, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 545 (03): : 613 - 623
  • [37] ATLAS Lquid Argon Hadronic Calorimeters
    Orr, RS
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS , DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2004, 2 : 218 - 226
  • [38] Upgrade of the H1 liquid argon calorimeter trigger
    Maracek, R
    Babaev, A
    Brettel, H
    Carli, T
    Dulny, B
    Fent, J
    Grindhammer, G
    Haberer, W
    Kiesling, C
    Köhne, JH
    Osthoff, A
    Pimpl, M
    Reisert, B
    Rüter, K
    Schörner, T
    Wegner, A
    Weissbach, P
    Borras, K
    Fleischer, M
    Lüke, D
    Rick, H
    Spiekermann, J
    Wacker, K
    Wegener, D
    Heinemann, B
    Tsipolitis, G
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2000, : 583 - 590
  • [39] The clock and control system for the ATLAS Liquid Argon Calorimeter Phase-I upgrade
    Xiao, L.
    Liu, C.
    Liu, T.
    Chen, H.
    Chen, J.
    Chen, K.
    Feng, Y.
    Gong, D.
    Guo, D.
    He, H.
    Hou, S.
    Huang, G.
    Sun, X.
    Tang, Y.
    Teng, P. -K.
    Xiang, A. C.
    Xu, H.
    Ye, J.
    You, Y.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [40] Development of ATLAS Liquid Argon Calorimeters Readout Electronics for HL-LHC
    Chen, Kai