Molecularly imprinted polymer-sol-gel tablet toward micro-solid phase extraction: I. Determination of methadone in human plasma utilizing liquid chromatography-tandem mass spectrometry

被引:37
|
作者
El-Beqqali, Aziza [1 ]
Abdel-Rehim, Mohamed [1 ]
机构
[1] Stockholm Univ, Dept Environm Sci & Analyt Chem, SE-10691 Stockholm, Sweden
关键词
Molecularly imprinted polymer; Sol-gel; Tablet; Micro-solid phase extraction; Methadone; Human plasma; CARTRIDGES COUPLED ONLINE; PACKED SORBENT MEPS; CAPILLARY GC-MS; SAMPLE PREPARATION; LOCAL-ANESTHETICS; MICROEXTRACTION FIBERS; SELECTIVE EXTRACTION; RAPID ANALYSIS; DRUGS; DESIGN;
D O I
10.1016/j.aca.2016.07.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work molecularly imprinted sol-gel tablet (MIP-Tablet) was prepared. The MIP-sol-gel was prepared as a thin layer on polyethylene material in a tablet form. Methadone-d(9) was selected as the template and 3-(propylmethacrylate)-trimethoxysilane was used as precursor. MIP-Tablet was applied for micro-solid phase extraction (m-SPE). The MIP-Tablet was used for the determination of methadone in human plasma samples utilizing liquid chromatography-tandem mass spectrometry; and each tablet could be used twenty times. The extraction time was 10 min while desorption time was 6 min. Factors affecting the extraction efficiency such as desorption solvents, sample pH, salt addition, extraction time, desorption time and adsorption capacity were investigated. The calibration curves were obtained within the range of 5-5000 ng/mL using methadone in human plasma samples. The coefficients of determination (r(2)) values were >= 0.999 for all runs and the extraction recovery was >80%. The accuracy values for quality control samples varied from +3.6 to +9.7% and the inter-day precision (RSD %) values were ranged from 5.0 to 8.0%. The limit of detection was 1.0 ng/mL and the lower limit of quantification was 5 ng/mL utilizing methadone in human plasma samples. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:116 / 122
页数:7
相关论文
共 50 条
  • [21] Sensitive, selective and rapid determination of lafutidine in human plasma by solid phase extraction-liquid chromatography-tandem mass spectrometry
    M. Yadav
    V. Trivedi
    V. Upadhyay
    G. Shah
    H. Shah
    A. Upadhyay
    S. Goswami
    P. S. Shrivastav
    Journal of Analytical Chemistry, 2014, 69 : 448 - 460
  • [22] Simultaneous Determination of 11 Aminoglycoside Residues in Honey, Milk, and Pork by Liquid Chromatography with Tandem Mass Spectrometry and Molecularly Imprinted Polymer Solid Phase Extraction
    Yang, Bixia
    Wang, Lian
    Luo, Chunying
    Wang, Xixi
    Sun, Chengjun
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (06) : 1869 - 1878
  • [23] Preparation of magnetic molecularly imprinted polymer for the extraction of melamine from milk followed by liquid chromatography-tandem mass spectrometry
    He, Dong
    Zhang, Xiaopan
    Gao, Bo
    Wang, Long
    Zhao, Qi
    Chen, Haiyan
    Wang, Hui
    Zhao, Chun
    FOOD CONTROL, 2014, 36 (01) : 36 - 41
  • [24] Determination of eptifibatide concentration in human plasma utilizing the liquid chromatography-tandem mass spectrometry method
    Liu, Jia
    Duan, Xiaotao
    Chen, Xiaoyan
    Zhong, Dafang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (5-6): : 527 - 532
  • [25] Sesame oil determination by solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Xinjing Dou
    Liangxiao Zhang
    Peiwu Li
    Huali Xie
    Huhu Lang
    Xiaomei Chen
    Li Yu
    Wen Zhang
    Qi Zhang
    OilCropScience, 2017, 2 (03) : 181 - 186
  • [26] Determination of 11Kinds of Aminoglycosides in Aquatic Products by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry with Molecularly Imprinted Polymers Solid Phase Extraction
    Huang Yuan-Fei
    Lou Xiao-Yi
    Zhou Zhe
    Wang Yang
    Kong Cong
    Huang Dong-Mei
    Cai You-Qiong
    Yu Hui-Juan
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (03) : 454 - 461
  • [27] Determination of fluoroquinolone antibiotics in environmental water samples based on magnetic molecularly imprinted polymer extraction followed by liquid chromatography-tandem mass spectrometry
    Chen, Ligang
    Zhang, Xiaopan
    Xu, Yang
    Du, Xiaobo
    Sun, Xin
    Sun, Lei
    Wang, Hui
    Zhao, Qi
    Yu, Aimin
    Zhang, Hanqi
    Ding, Lan
    ANALYTICA CHIMICA ACTA, 2010, 662 (01) : 31 - 38
  • [28] Surface molecularly imprinted solid-phase extraction for the determination of vancomycin and norvancomycin in milk by liquid chromatography coupled to tandem mass spectrometry
    Zhou, Hao
    Liu, Rong
    Chen, Qianqian
    Zheng, Xiantong
    Qiu, Jingli
    Ding, Tongyan
    He, Limin
    FOOD CHEMISTRY, 2022, 369
  • [29] Micro-solid phase extraction coupled with high-performance liquid chromatography-tandem mass spectrometry for the determination of stimulants, hallucinogens, ketamine and phencyclidine in oral fluids
    Sergi, Manuel
    Compagnone, Dario
    Curini, Roberta
    D'Ascenzo, Giuseppe
    Del Carlo, Michele
    Napoletano, Sabino
    Risoluti, Roberta
    ANALYTICA CHIMICA ACTA, 2010, 675 (02) : 132 - 137
  • [30] Fast determination of hydroxylated polychlorinated biphenyls in human plasma by online solid phase extraction coupled to liquid chromatography-tandem mass spectrometry
    Quinete, Natalia
    Kraus, Thomas
    Belov, Vladimir N.
    Aretz, Christina
    Esser, Andre
    Schettgen, Thomas
    ANALYTICA CHIMICA ACTA, 2015, 888 : 94 - 102