Metal Artifact Reduction in Computed Tomography Using Nonequispaced Fourier Transform

被引:11
|
作者
Kratz, Baerbel [1 ]
Buzug, Thorsten M. [1 ]
机构
[1] Univ Lubeck, IMT, D-23538 Lubeck, Germany
关键词
CT; RECONSTRUCTION;
D O I
10.1109/NSSMIC.2009.5401974
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Metal objects in the field of view of a computed tomography (CT) scanner cause several artifacts inside the reconstructed image. By reducing the influence of these metallic objects the image quality can be enhanced. We propose a metal artifact reduction (MAR) method based on interpolation using Nonequispaced Fast Fourier Transforms (NFFT). By damping the transformation additional a priori knowledge may be included during the interpolation step. The results are reconstructed with a weighted maximum likelihood expectation maximization algorithm (lambda-MLEM) and finally compared to two common one dimensional polynomial interpolation methods.
引用
收藏
页码:2720 / 2723
页数:4
相关论文
共 50 条
  • [1] Normalized metal artifact reduction (NMAR) in computed tomography
    Meyer, Esther
    Raupach, Rainer
    Lell, Michael
    Schmidt, Bernhard
    Kachelriess, Marc
    MEDICAL PHYSICS, 2010, 37 (10) : 5482 - 5493
  • [2] Metal Artifact Reduction in Computed Tomography by Constrained Optimization
    Zhang, Xiaomeng
    Wang, Jing
    Xing, Lei
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [3] Normalized Metal Artifact Reduction (NMAR) in Computed Tomography
    Meyer, Esther
    Bergner, Frank
    Raupach, Rainer
    Flohr, Thomas
    Kachelriess, Marc
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3251 - +
  • [4] Evaluation of Metal Artifact Reduction software in Computed Tomography
    Eslam M.
    Abdelaziz M.
    Eslam, Mamoun, 1600, Mashhad University of Medical Sciences (17): : 298 - 302
  • [5] Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    Fabian Bamberg
    Alexander Dierks
    Konstantin Nikolaou
    Maximilian F. Reiser
    Christoph R. Becker
    Thorsten R. C. Johnson
    European Radiology, 2011, 21 : 1424 - 1429
  • [6] Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    Bamberg, Fabian
    Dierks, Alexander
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Becker, Christoph R.
    Johnson, Thorsten R. C.
    EUROPEAN RADIOLOGY, 2011, 21 (07) : 1424 - 1429
  • [7] A Normalized Metal Artifact Reduction Method Using an Artifact-Reduced Prior for Dental Computed Tomography
    Park, Chulkyu
    Lee, Dongyeon
    Lim, Younghwan
    Kim, Guna
    Kim, Kyuseok
    Cho, Hyosung
    Seo, Changwoo
    Lim, Hyunwoo
    Lee, Hunwoo
    Park, Soyoung
    Kang, Seokyoon
    Park, Jeongeun
    Jeon, Duhee
    Kim, Woosung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 74 (03) : 298 - 304
  • [8] A Normalized Metal Artifact Reduction Method Using an Artifact-Reduced Prior for Dental Computed Tomography
    Chulkyu Park
    Dongyeon Lee
    Younghwan Lim
    Guna Kim
    Kyuseok Kim
    Hyosung Cho
    Changwoo Seo
    Hyunwoo Lim
    Hunwoo Lee
    Soyoung Park
    Seokyoon Kang
    Jeongeun Park
    Duhee Jeon
    Woosung Kim
    Journal of the Korean Physical Society, 2019, 74 : 298 - 304
  • [9] Frequency split metal artifact reduction (FSMAR) in computed tomography
    Meyer, Esther
    Raupach, Rainer
    Lell, Michael
    Schmidt, Bernhard
    Kachelriess, Marc
    MEDICAL PHYSICS, 2012, 39 (04) : 1904 - 1916
  • [10] Normalized Metal Artifact Reduction in Head and Neck Computed Tomography
    Lell, Michael M.
    Meyer, Esther
    Kuefner, Michael A.
    May, Matthias S.
    Raupach, Rainer
    Uder, Michael
    Kachelriess, Marc
    INVESTIGATIVE RADIOLOGY, 2012, 47 (07) : 415 - 421