Measurement of lesion area and volume by three-dimensional spoiled gradient-echo MR imaging in osteonecrosis of the femoral head

被引:26
|
作者
Kishida, Y
Nishii, T
Sugano, N
Nakanishi, K
Sakai, T
Miki, H
Ochi, T
Yoshikawa, H
机构
[1] Osaka Univ, Sch Med, Dept Orthopaed Surg, Suita, Osaka 5640871, Japan
[2] Osaka Univ, Sch Med, Dept Radiol, Suita, Osaka 5640871, Japan
关键词
femoral head; three-dimensional spoiled gradient-echo (3D SPGR) imaging; volume; area; osteonecrosis;
D O I
10.1016/S0736-0266(03)00043-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this investigation is to evaluate the diagnostic ability of three-dimensional spoiled gradient-echo (3D SPGR) magnetic resonance (MR) imaging in cases of osteonecrosis of the femoral head (ONFH), and to determine the accuracy of 3D SPGR imaging in area and volume measurement of ONFH. T1-weighted spin-echo (SE) and 3D SPGR imaging were performed on 20 femoral heads obtained from patients with ONFH. After MR imaging, the femoral heads were cut parallel to the imaging plane and were evaluated histologically. Areas and volumes of necrotic lesions were measured with a computer program and the deviation between MR images and anatomical measurements was evaluated. A low signal intensity band on 3D SPGR MR images was observed in all femoral heads and corresponded histologically to repaired marrow with viable fibrous mesenchymal tissue. The area proximate to the low band area coincided with the necrotic region. Both area and volume measurements by T1-weighted SE and 3D SPGR images showed a strong correlation to histological measurements. The discrepancies between histological and imaging results were minimal in 3D SPGR imaging, especially at the anterior and posterior portions of the femoral head. Three-dimensional SPGR imaging provides more accurate measurements of the area and volume of a necrotic lesion than T1-weighted SE imaging. (C) 2003 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:850 / 858
页数:9
相关论文
共 50 条
  • [41] 3-DIMENSIONAL GRADIENT-ECHO MR IMAGING OF THE KNEE - COMPARISON WITH ARTHROSCOPY IN 100 PATIENTS
    HERON, CW
    CALVERT, PT
    RADIOLOGY, 1992, 183 (03) : 839 - 844
  • [42] T1-weighted spoiled gradient-echo MR imaging of focal hepatic lesion: comparison of in-phase vs opposed-phase pulse sequence
    P. Soyer
    Y. Rondeau
    A.-C. Dufresne
    L. Spelle
    E. Somveille
    A. Scherrer
    R. Rymer
    European Radiology, 1997, 7 : 1048 - 1053
  • [43] T1-weighted spoiled gradient-echo MR imaging of focal hepatic lesion: Comparison of in-phase vs opposed-phase pulse sequence
    Soyer, P
    Rondeau, Y
    Dufresne, AC
    Spelle, L
    Somveille, E
    Scherrer, A
    Rymer, R
    EUROPEAN RADIOLOGY, 1997, 7 (07) : 1048 - 1053
  • [44] Mechanics of femoral head osteonecrosis using three-dimensional finite element method
    Jin-Won Yang
    Kyung-Hoi Koo
    Min-Cheol Lee
    Philip Yang
    Myunggyu D. Noh
    Shin-Yoon Kim
    Kang-Il Kim
    Yong-Chan Ha
    Man-Soo Joun
    Archives of Orthopaedic and Trauma Surgery, 2002, 122 : 88 - 92
  • [45] Mechanics of femoral head osteonecrosis using three-dimensional finite element method
    Yang, JW
    Koo, KH
    Lee, MC
    Yang, P
    Noh, MD
    Kim, SY
    Kim, KI
    Ha, YC
    Joun, MS
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (02) : 88 - 92
  • [46] Increased spatial resolution using a three-dimensional T1-weighted gradient-echo MR sequence results in greater hypointense lesion volumes in multiple sclerosis
    Filippi, M
    Rocca, MA
    Horsfield, MA
    Rovaris, M
    Pereira, C
    Yousry, TA
    Colombo, B
    Comi, G
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1998, 19 (02) : 235 - 238
  • [47] Use of gadolinium-enhanced, ultrafast, three-dimensional, spoiled gradient-echo magnetic resonance angiography in the preoperative evaluation of living renal allograft donors
    Buzzas, GR
    Shield, CF
    Pay, NT
    Neuman, MJ
    Smith, JL
    TRANSPLANTATION, 1997, 64 (12) : 1734 - 1737
  • [48] Internal derangements of the temporomandibular joint: comparison of assessment with three-dimensional gradient-echo and spin-echo MRI
    I. Yamada
    Y. Murata
    H. Shibuya
    S. Suzuki
    Neuroradiology, 1997, 39 : 661 - 667
  • [49] DETECTION OF KNEE HYALINE CARTILAGE DEFECTS USING FAT-SUPPRESSED 3-DIMENSIONAL SPOILED GRADIENT-ECHO MR-IMAGING - COMPARISON WITH STANDARD MR-IMAGING AND CORRELATION WITH ARTHROSCOPY
    DISLER, DG
    MCCAULEY, TR
    WIRTH, CR
    FUCHS, MD
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) : 377 - 382
  • [50] Internal derangements of the temporomandibular joint: comparison of assessment with three-dimensional gradient-echo and spin-echo MRI
    Yamada, I
    Murata, Y
    Shibuya, H
    Suzuki, S
    NEURORADIOLOGY, 1997, 39 (09) : 661 - 667