Experimental Set-up for FLASH Proton Irradiation of Small Animals Using a Clinical System

被引:198
|
作者
Patriarca, Annalisa [1 ]
Fouillade, Charles [1 ,2 ]
Auger, Michel [1 ]
Martin, Frederic [1 ]
Pouzoulet, Frederic [3 ]
Nauraye, Catherine [1 ]
Heinrich, Sophie [3 ]
Favaudon, Vincent [2 ]
Meyroneinc, Samuel [1 ]
Dendale, Remi [1 ]
Mazal, Alejandro [1 ]
Poortmans, Philip [1 ]
Verrelle, Pierre [1 ,4 ]
De Marzi, Ludovic [1 ]
机构
[1] PSL Res Univ, Inst Curie, Dept Radiat Oncol, Paris, France
[2] PSL Res Univ, Inst Curie, INSERM, U1021,UMR3347, Orsay, France
[3] PSL Res Univ, Inst Curie, Translat Res Dept, Expt Radiotherapy Platform, Orsay, France
[4] PSL Res Univ, Inst Curie, INSERM, U1196,UMR9187, Orsay, France
关键词
DOSE-RATE; LINEAR-ACCELERATOR; CELL-SURVIVAL; THERAPY; BEAMS; DOSIMETRY; FILMS; ELECTRON; DESIGN;
D O I
10.1016/j.ijrobp.2018.06.403
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Recent in vivo investigations have shown that short pulses of electrons at very high dose rates (FLASH) are less harmful to healthy tissues but just as efficient as conventional dose-rate radiation to inhibit tumor growth. In view of the potential clinical value of FLASH and the availability of modern proton therapy infrastructures to achieve this goal, we herein describe a series of technological developments required to investigate the biology of FLASH irradiation using a commercially available clinical proton therapy system. Methods and Materials: Numerical simulations and experimental dosimetric characterization of a modified clinical proton beamline, upstream from the isocenter, were performed with a Monte Carlo toolkit and different detectors. A single scattering system was optimized with a ridge filter and a high current monitoring system. In addition, a submillimetric set-up protocol based on image guidance using a digital camera and an animal positioning system was also developed. Results: The dosimetric properties of the resulting beam and monitoring system were characterized; linearity with dose rate and homogeneity for a 12 x 12 mm(2) field size were assessed. Dose rates exceeding 40 Gy/s at energies between 138 and 198 MeV were obtained, enabling uniform irradiation for radiobiology investigations of small animals in a modified clinical proton beam line. Conclusions: This approach will enable us to conduct FLASH proton therapy experiments on small animals, specifically for mouse lung irradiation. Dose rates exceeding 40 Gy/s were achieved, which was not possible with the conventional clinical mode of the existing beamline. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:619 / 626
页数:8
相关论文
共 50 条
  • [41] A New Experimental Set-up To Run Neuromuscular Tests
    Faci, Nadir
    Bidias, Simon Pierre Boyogueno
    Plamondon, Rejean
    Bergeron, Nicolas
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION AND ARTIFICIAL INTELLIGENCE (ICPRAI 2018), 2018, : 753 - 757
  • [42] Experimental set-up and the associated model for squeal analysis
    Duboc, Martin
    Magnier, Vincent
    Brunel, Jean-Francois
    Dufrenoy, Philippe
    MECHANICS & INDUSTRY, 2020, 21 (02)
  • [43] EXPERIMENTAL SET-UP FOR ANALYSIS OF SUBSEA EQUIPMENT INSTALLATION
    de Mello, Pedro C.
    Rateiro, Felipe
    Fujarra, Andre L. C.
    Oshiro, Anderson T.
    Neves, Cassiano R.
    dos Santos, Melquisedec F.
    Eduardo, Tannuri A.
    OMAE2011: PROCEEDINGS OF THE ASME 30TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, VOL 6: OCEAN ENGINEERING, 2011, : 763 - +
  • [44] LOGIC CONTROL OF A STREAMER CHAMBER EXPERIMENTAL SET-UP
    ROCHE, G
    FARGEIX, J
    GIRARD, G
    RAMOS, F
    NUCLEAR INSTRUMENTS & METHODS, 1970, 86 (01): : 61 - &
  • [45] Entomotoxicology, experimental set-up and interpretation for forensic toxicologists
    Gosselin, Matthias
    Wille, Sarah M. R.
    Ramirez Fernandez, Maria del Mar
    Di Fazio, V.
    Samyn, Nele
    De Boeck, Gert
    Bourel, Benoit
    FORENSIC SCIENCE INTERNATIONAL, 2011, 208 (1-3) : 1 - 9
  • [46] EXPERIMENTAL SET-UP FOR GAS BALANCE MEASUREMENT AT JET
    USSELMANN, E
    HEMMERICH, JL
    HOLLAND, D
    GROBUSCH, L
    SCHARGITZ, U
    SARTORI, R
    SAIBENE, G
    VACUUM, 1990, 41 (4-6) : 1515 - 1518
  • [47] An experimental energy set-up for wireless battery recharging
    Angrisani, Leopoldo
    d'Alessandro, Guido
    D'Arco, Mauro
    2015 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2015, : 1699 - 1704
  • [48] Experimental Set-up of Laser Ultrasonic Techniques and Applications
    周辛庚
    何存富
    Tsinghua Science and Technology, 1997, (02) : 62 - 66
  • [49] Electrovibrostimulation during the training of sportsmen, an experimental set-up
    Van Zwieten, Koos Jaap
    Verhaegen, Iris
    T Eijnde, Bert Op
    Zinkovsky, Anatoly
    Zubova, Irina
    Schmidt, Klaus
    Lippens, Peter
    JOURNAL OF VIBROENGINEERING, 2007, 9 (04) : 50 - 54
  • [50] Experimental set-up for the measurement of the thermal conductivity of liquids
    Codreanu, C.
    Codreanu, N-I.
    Obreja, V. V. N.
    ROMANIAN JOURNAL OF INFORMATION SCIENCE AND TECHNOLOGY, 2007, 10 (03): : 215 - 231