Experimental Set-up for FLASH Proton Irradiation of Small Animals Using a Clinical System

被引:198
|
作者
Patriarca, Annalisa [1 ]
Fouillade, Charles [1 ,2 ]
Auger, Michel [1 ]
Martin, Frederic [1 ]
Pouzoulet, Frederic [3 ]
Nauraye, Catherine [1 ]
Heinrich, Sophie [3 ]
Favaudon, Vincent [2 ]
Meyroneinc, Samuel [1 ]
Dendale, Remi [1 ]
Mazal, Alejandro [1 ]
Poortmans, Philip [1 ]
Verrelle, Pierre [1 ,4 ]
De Marzi, Ludovic [1 ]
机构
[1] PSL Res Univ, Inst Curie, Dept Radiat Oncol, Paris, France
[2] PSL Res Univ, Inst Curie, INSERM, U1021,UMR3347, Orsay, France
[3] PSL Res Univ, Inst Curie, Translat Res Dept, Expt Radiotherapy Platform, Orsay, France
[4] PSL Res Univ, Inst Curie, INSERM, U1196,UMR9187, Orsay, France
关键词
DOSE-RATE; LINEAR-ACCELERATOR; CELL-SURVIVAL; THERAPY; BEAMS; DOSIMETRY; FILMS; ELECTRON; DESIGN;
D O I
10.1016/j.ijrobp.2018.06.403
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Recent in vivo investigations have shown that short pulses of electrons at very high dose rates (FLASH) are less harmful to healthy tissues but just as efficient as conventional dose-rate radiation to inhibit tumor growth. In view of the potential clinical value of FLASH and the availability of modern proton therapy infrastructures to achieve this goal, we herein describe a series of technological developments required to investigate the biology of FLASH irradiation using a commercially available clinical proton therapy system. Methods and Materials: Numerical simulations and experimental dosimetric characterization of a modified clinical proton beamline, upstream from the isocenter, were performed with a Monte Carlo toolkit and different detectors. A single scattering system was optimized with a ridge filter and a high current monitoring system. In addition, a submillimetric set-up protocol based on image guidance using a digital camera and an animal positioning system was also developed. Results: The dosimetric properties of the resulting beam and monitoring system were characterized; linearity with dose rate and homogeneity for a 12 x 12 mm(2) field size were assessed. Dose rates exceeding 40 Gy/s at energies between 138 and 198 MeV were obtained, enabling uniform irradiation for radiobiology investigations of small animals in a modified clinical proton beam line. Conclusions: This approach will enable us to conduct FLASH proton therapy experiments on small animals, specifically for mouse lung irradiation. Dose rates exceeding 40 Gy/s were achieved, which was not possible with the conventional clinical mode of the existing beamline. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:619 / 626
页数:8
相关论文
共 50 条
  • [1] A Set-Up For Murine Breast Irradiation With Pulsed FLASH Radiotherapy Using A Clinical Linac
    Xie, D. H.
    Li, Y. C.
    Ma, S.
    Yang, X.
    Chen, Y.
    Mei, Y.
    Peng, L. X.
    Lang, Y. H.
    Chen, A. Q.
    Huang, B. J.
    Huang, X.
    Qian, C. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E528 - E529
  • [2] Transcranial magnetic stimulation set-up for small animals
    Nieminen, Jaakko O.
    Pospelov, Alexey S.
    Koponen, Lari M.
    Yrjola, Pauliina
    Shulga, Anastasia
    Khirug, Stanislav
    Rivera, Claudio
    FRONTIERS IN NEUROSCIENCE, 2022, 16
  • [3] Experimental set-up
    Prace Naukowe Instytutu Technologii Budowy Maszyn Politechniki Wroclawskiej, 1991, 48 (13):
  • [4] Experimental Platform for Ultra-high Dose Rate FLASH Irradiation of Small Animals Using a Clinical Linear Accelerator
    Schuler, Emil
    Trovati, Stefania
    King, Gregory
    Lartey, Frederick
    Rafat, Marjan
    Villegas, Manuel
    Praxel, A. Joe
    Loo, Billy W., Jr.
    Maxim, Peter G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 97 (01): : 195 - 203
  • [5] Development of proton beam irradiation system for small animals using FFAG accelerator
    Tanaka, H.
    Takata, T.
    Ishi, Y.
    Uesugi, T.
    Kuriyama, Y.
    Watanabe, T.
    Sakurai, Y.
    Kawabata, S.
    Masunag, S-, I
    Suzuki, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 922 : 230 - 234
  • [6] IGLIAS: A new experimental set-up for low temperature irradiation studies at large irradiation facilities
    Auge, B.
    Been, T.
    Boduch, P.
    Chabot, M.
    Dartois, E.
    Madi, T.
    Ramillon, J. M.
    Ropars, F.
    Rothard, H.
    Voivenel, P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (07):
  • [7] Experimental set-up for the development of the ADDASAT attitude control system
    Rugescu, Radu D.
    Al Barbelian, Mihai
    Ilincariu, Andrei
    PROCEEDINGS OF 6TH INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN SPACE TECHNOLOGIES (RAST 2013), 2013, : 281 - 284
  • [8] Fabrication of experimental set-up and testing
    Department of Mechanical Engineering, Sri Ranganathar Institute of Engineering and Technology, Coimbatore
    Tamil Nadu, India
    不详
    Tamil Nadu, India
    不详
    SpringerBriefs Appl. Sci. Technol., 9783319029849 (35-49):
  • [9] EXPERIMENTAL SET-UP FOR ULTRALOW TEMPERATURES
    AVENEL, O
    ROUBEAU, P
    BULLETIN D INFORMATIONS SCIENTIFIQUES ET TECHNIQUES DU COMMISSARIAT A L ENERGIE ATOMIQUE, 1976, (214): : 59 - 63
  • [10] Set-up of a small instrument using TXRF with high sensitivity
    Tian, Yuhong
    Wang, Ruiguang
    Wang, Zhiguo
    Liu, Kai
    Zheng, Suhua
    He-Huaxue yu Fangshe Huaxue/Journal of Nuclear and Radiochemistry, 1996, 18 (03): : 158 - 163