Double-arc volumetric modulated therapy improves dose distribution compared to static gantry IMRT and 3D conformal radiotherapy for adjuvant therapy of gastric cancer

被引:17
|
作者
Zhang, Tao [1 ]
Liang, Zhi-Wen [1 ]
Han, Jun [1 ]
Bi, Jian-Ping [1 ]
Yang, Zhi-Yong [1 ]
Ma, Hong [1 ]
机构
[1] Huazhong Univ Sci & Technol, Canc Ctr Union Hosp, Tongji Med Coll, Wuhan 430022, Hubei, Peoples R China
来源
RADIATION ONCOLOGY | 2015年 / 10卷
关键词
Double-arc volumetric modulated arc therapy; Intensity-modulated radiotherapy; Three-dimensional conformal radiotherapy; Gastric cancer; RADIATION-THERAPY; HEPATOCELLULAR-CARCINOMA; ESOPHAGEAL CANCER; CHEMORADIOTHERAPY; FEASIBILITY; REDUCTION; INJURY; PLANS;
D O I
10.1186/s13014-015-0420-x
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The objective of this study was to compare the dose distributions of RapidArc (RA), static gantry intensity-modulated radiotherapy (IMRT), and three-dimensional conformal radiotherapy (3DCRT) as adjuvant radiotherapy modalities for the treatment of gastric cancer. Methods: Fifteen patients with gastric cancer that underwent limited lymphadenectomy of perigastric lymph nodes were included in this study. Dosimetric values for a total dose of 45 Gy (1.8 Gy/day) were calculated for the RapidArc, IMRT, and 3DCRT modalities. The following parameters were compared: D-99%, D-1%, V-95%, V-107%, and conformity and homogeneity index values (CI and HI, respectively) for the planned target volume (PTV). Dose volume histogram (DVH) and dose distribution of the organs at risk (OAR), as the maximal dose to the spinal cord, V-30 and V-40 of the small bowel, and V-20, V-30 of liver and kidney were also assessed respectively. Results: RA, IMRT, and 3DCRT all achieved desirable PTV coverage. However, RA and IMRT significantly decreased D-1% and V-107%, and provided better CI and HI values compared with 3DCRT (P< 0.05). Moreover, RA also achieved a significantly lower maximum dose for the spinal cord, liver V-30, and kidney V-20 compared to IMRT and 3DCRT; while the mean dose for these three organ types did not differ for the RA, IMRT, and 3DCRT plans. Conclusions: Both RA and IMRT achieved favorable PTV coverage compared to 3DCRT. In addition, RA achieved better dosimetry than IMRT and 3DCRT, and provided better protection for the spinal cord, liver, and kidneys.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Dosimetric comparison of 3-dimensional conformal radiotherapy, volumetric modulated arc therapy, and helical tomotherapy for postoperative gastric cancer patients
    Onal, Cem
    Dolek, Yemliha
    Yildirim, Berna Akkus
    JAPANESE JOURNAL OF RADIOLOGY, 2018, 36 (01) : 30 - 39
  • [42] Dosimetric comparison of 3-dimensional conformal radiotherapy, volumetric modulated ARC therapy, and helical tomotherapy for postoperative gastric cancer patients
    Onal, C.
    Dolek, Y.
    Yildirim, B. Akkus
    EUROPEAN JOURNAL OF CANCER, 2017, 72 : S81 - S81
  • [43] DOSIMETRIC COMPARISON OF VOLUMETRIC INTENSITY-MODULATED ARC (RAPIDARC) THERAPY, INTENSITY-MODULATED RADIOTHERAPY, AND 3D CONFORMAL RADIOTHERAPY FOR PRIMARY LIVER TUMOURS
    John, Jacob
    Sivasevan, Roshni
    Sudha, Arun Sankar
    Sivanandan, Choondal Devan
    Abdurahman, Sajeed
    Paramu, Raghukumar
    Sreedevi, Shaiju Vasudevan
    George, Preethi Sara
    Jayaprakash, Puthuveettil Govindan
    EUROPEAN JOURNAL OF CANCER, 2015, 51 : E34 - E34
  • [44] Volumetric modulated arc therapy using flattening filter free beams compared with static IMRT and 3DCRT for advanced esophageal cancer
    Vanetti, E.
    Cozzi, L.
    Nicolini, G.
    Fogliata, A.
    Clivio, A.
    Mahantashetty, U.
    Laksar, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (08) : 753 - 753
  • [45] Critical Appraisal of the Risk of Secondary Cancer Induction From Breast Radiation Therapy With Volumetric Modulated Arc Therapy Relative to 3D Conformal Therapy
    Fogliata, Antonella
    De Rose, Fiorenza
    Franceschini, Davide
    Stravato, Antonella
    Seppala, Jan
    Scorsetti, Marta
    Cozzi, Luca
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (03): : 785 - 793
  • [46] A dose-volume intercomparison of volumetric-modulated arc therapy, 3D static conformal, and rotational conformal techniques for portal vein tumor thrombus in hepatocellular carcinoma
    Ogino, Ryo
    Hosono, Masako
    Ishii, Kentaro
    Tatsumi, Daisaku
    Tsutsumi, Shinichi
    Miki, Yoshitaka
    Masuoka, Yutaka
    Shimatani, Yasuhiko
    Miki, Yukio
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (04) : 697 - 705
  • [47] 3D Dose Reconstruction of Volumetric Modulated Arc Therapy From Delivered EPID Dose Image
    Yoon, J.
    Jung, J.
    Kim, J.
    Yeo, I.
    MEDICAL PHYSICS, 2014, 41 (06) : 221 - 221
  • [48] DOSIMETRIC COMPARISON OF INTENSITY-MODULATED RADIATION THERAPY, HELICAL TOMOTHERAPY, VOLUMETRIC MODULATED ARC THERAPY, AND 3D-CONFORMAL RADIOTHERAPY IN THE POST-OPERATIVE TREATMENT OF GASTRIC CANCER PATIENTS
    Loewen, S.
    Joseph, K.
    Usmani, N.
    Tankel, K.
    Severin, D.
    Nijjar, T.
    Warkentin, H.
    Syme, A.
    Williams, D.
    Field, C.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S36 - S37
  • [49] Peripheral dose measurements in cervical cancer radiotherapy: a comparison of volumetric modulated arc therapy and step-and-shoot IMRT techniques
    Jia, Ming X.
    Zhang, Xu
    Yin, Ce
    Feng, Ge
    Li, Na
    Gao, Song
    Liu, Da W.
    RADIATION ONCOLOGY, 2014, 9
  • [50] Peripheral dose measurements in cervical cancer radiotherapy: a comparison of volumetric modulated arc therapy and step-and-shoot IMRT techniques
    Ming X Jia
    Xu Zhang
    Ce Yin
    Ge Feng
    Na Li
    Song Gao
    Da W Liu
    Radiation Oncology, 9