Double-arc volumetric modulated therapy improves dose distribution compared to static gantry IMRT and 3D conformal radiotherapy for adjuvant therapy of gastric cancer

被引:17
|
作者
Zhang, Tao [1 ]
Liang, Zhi-Wen [1 ]
Han, Jun [1 ]
Bi, Jian-Ping [1 ]
Yang, Zhi-Yong [1 ]
Ma, Hong [1 ]
机构
[1] Huazhong Univ Sci & Technol, Canc Ctr Union Hosp, Tongji Med Coll, Wuhan 430022, Hubei, Peoples R China
来源
RADIATION ONCOLOGY | 2015年 / 10卷
关键词
Double-arc volumetric modulated arc therapy; Intensity-modulated radiotherapy; Three-dimensional conformal radiotherapy; Gastric cancer; RADIATION-THERAPY; HEPATOCELLULAR-CARCINOMA; ESOPHAGEAL CANCER; CHEMORADIOTHERAPY; FEASIBILITY; REDUCTION; INJURY; PLANS;
D O I
10.1186/s13014-015-0420-x
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The objective of this study was to compare the dose distributions of RapidArc (RA), static gantry intensity-modulated radiotherapy (IMRT), and three-dimensional conformal radiotherapy (3DCRT) as adjuvant radiotherapy modalities for the treatment of gastric cancer. Methods: Fifteen patients with gastric cancer that underwent limited lymphadenectomy of perigastric lymph nodes were included in this study. Dosimetric values for a total dose of 45 Gy (1.8 Gy/day) were calculated for the RapidArc, IMRT, and 3DCRT modalities. The following parameters were compared: D-99%, D-1%, V-95%, V-107%, and conformity and homogeneity index values (CI and HI, respectively) for the planned target volume (PTV). Dose volume histogram (DVH) and dose distribution of the organs at risk (OAR), as the maximal dose to the spinal cord, V-30 and V-40 of the small bowel, and V-20, V-30 of liver and kidney were also assessed respectively. Results: RA, IMRT, and 3DCRT all achieved desirable PTV coverage. However, RA and IMRT significantly decreased D-1% and V-107%, and provided better CI and HI values compared with 3DCRT (P< 0.05). Moreover, RA also achieved a significantly lower maximum dose for the spinal cord, liver V-30, and kidney V-20 compared to IMRT and 3DCRT; while the mean dose for these three organ types did not differ for the RA, IMRT, and 3DCRT plans. Conclusions: Both RA and IMRT achieved favorable PTV coverage compared to 3DCRT. In addition, RA achieved better dosimetry than IMRT and 3DCRT, and provided better protection for the spinal cord, liver, and kidneys.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Double-arc volumetric modulated therapy improves dose distribution compared to static gantry IMRT and 3D conformal radiotherapy for adjuvant therapy of gastric cancer
    Tao Zhang
    Zhi-Wen Liang
    Jun Han
    Jian-Ping Bi
    Zhi-Yong Yang
    Hong Ma
    Radiation Oncology, 10
  • [2] Comparison of IMRT and 3D Conformal Radiotherapy for Adjuvant Therapy for Gastric Cancer
    Minn, A.
    Fisher, G.
    Ford, J.
    Kunz, P.
    Norton, J.
    Koong, A.
    Chang, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S259 - S259
  • [3] High-dose radiotherapy in inoperable nonsmall cell lung cancer: Comparison of volumetric modulated arc therapy, dynamic IMRT and 3D conformal radiotherapy
    de Bree, Ingrid
    van Hinsberg, Marielle G. E.
    van Veelen, Lieneke R.
    MEDICAL DOSIMETRY, 2012, 37 (04) : 353 - 357
  • [4] Adjuvant RT for soft tissue sarcomas: volumetric modulated arc therapy vs 3D conformal radiotherapy
    Di Brina, L.
    Navarria, P.
    D'Agostino, G. R.
    De Rose, F.
    Iftode, C.
    Clerici, E.
    Lobefalo, F.
    Bertuzzi, A.
    Quagliuolo, V.
    Scorsetti, M.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S865 - S866
  • [5] Volumetric Modulation Arc Radiotherapy With Flattening Filter-Free Beams Compared With Static Gantry IMRT and 3D Conformal Radiotherapy for Advanced Esophageal Cancer: A Feasibility Study
    Nicolini, Giorgia
    Ghosh-Laskar, Sarbani
    Shrivastava, Shyam Kishore
    Banerjee, Sushovan
    Chaudhary, Suresh
    Agarwal, Jai Prakash
    Munshi, Anusheel
    Clivio, Alessandro
    Fogliata, Antonella
    Mancosu, Pietro
    Vanetti, Eugenio
    Cozzi, Luca
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (02): : 553 - 560
  • [6] Spinal Radiosugery: Comparison between Volumetric Modulated Arc Therapy and Static Gantry IMRT
    Chow, P.
    Agazaryan, N.
    Tenn, S.
    Lee, C.
    Gorgulho, A.
    DeSalles, A.
    Lee, P.
    Selch, M.
    Steinberg, M.
    MEDICAL PHYSICS, 2010, 37 (06) : 3314 - +
  • [7] Postoperative volumetric modulated arc therapy for sinonasal cancer: Improved survival compared with 3D conformal radiation therapy
    Frederic-Moreau, Thomas
    Piram, Lucie
    Bellini, Romain
    Martin, Fanny
    Miroir, Jessica
    Saroul, Nicolas
    Dang, Nathalie Pham
    Lapeyre, Michel
    Biau, Julian
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2019, 41 (02): : 448 - 455
  • [8] Volumetric modulated arc therapy versus 3D conformal radiotherapy for selected childhood neoplasms
    Chojnacka, Marzanna
    Zygmuntowicz-Pietka, Anna
    Semaniak, Anna
    Pedziwiatr, Katarzyna
    Dabrowski, Ryszard
    Skowronska-Gardas, Anna
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2015, 14 (01) : 35 - 42
  • [9] OPTIMIZATION OF RADIOTHERAPY TECHNIQUE IN APICAL LUNG TUMOUR: A COMPARATIVE STUDY OF 3D CONFORMAL RADIOTHERAPY (3D CRT) WITH INTENSITY MODULATED RADIOTHERAPY (IMRT) AND VOLUMETRIC MODULATED ARC THERAPY (VMAT)
    Martin, C.
    Harrowven, J.
    Fitchett, R.
    Ajithkumar, T. V.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S561 - S561
  • [10] Single-arc volumetric-modulated arc therapy (sVMAT) as adjuvant treatment for gastric cancer: Dosimetric comparisons with three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT)
    Wang, Xin
    Li, Guangjun
    Zhang, Yingjie
    Bai, Sen
    Xu, Feng
    Wei, Yuquan
    Gong, Youling
    MEDICAL DOSIMETRY, 2013, 38 (04) : 395 - 400