Measurement of Peri-Implant Bone Width with and without Metal Artifact Reduction Algorithm Using Two Cone-Beam Computed Tomography Software Programs

被引:2
|
作者
Hedayatipanah, Morad [1 ]
Salemi, Fatemeh [2 ]
Kamyari, Naser [3 ]
Yalpanian, Ashkan [4 ]
机构
[1] Hamadan Univ Med Sci, Fac Dent, Dept Periodont, Hamadan, Hamadan, Iran
[2] Hamadan Univ Med Sci, Fac Dent, Dept Oral & Maxillofacial Radiol, Hamadan, Hamadan, Iran
[3] Abadan Fac Med Sci, Dept Biostat, Abadan, Iran
[4] Hamadan Univ Med Sci, Fac Dent, Hamadan, Hamadan, Iran
关键词
Cone-Beam Computed Tomography; Dental Implants; Artifacts; CT; ACCURACY;
D O I
10.1590/pboci.2021.118
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To assess the effect of metal artifact reduction (MAR) algorithm of two cone-beam computed tomography (CBCT) software programs on the accuracy of peri-implant bone width measurements. Material and Methods: This in vitro study evaluated 35 bovine rib bone blocks measuring 8 x 8 x 11 mm. Titanium implants were inserted in bone blocks and placed in a wax model of mandible. CBCT scans were obtained with ProMax 3D and Cranex 3D CBCT systems with and without the MAR algorithm. The width of buccal and lingual bone plates surrounding the implant was measured on CBCT scans by two observers. The Cronbach's alpha was calculated to assess inter-observer agreement. The area under the curve (AUC), sensitivity and specificity values were calculated and compared. Results: The two observers had an excellent agreement. The accuracy of Cranex 3D was higher than that of ProMax 3D (p<0.05). Both CBCT systems showed higher accuracy when the MAR algorithm was not used (p<0.05). Both CBCT systems showed higher accuracy for measuring the width of the lingual plate than buccal plate (p<0.05). Conclusion: The application of MAR algorithm did not notably increase the measurement accuracy in any CBCT system. Cranex 3D showed generally higher measurement accuracy than ProMax 3D.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] A computational investigation for metal artifact reduction in cone-beam X-ray computed tomography
    Aootaphao, Sorapong
    Pintavirooj, Chuchart
    Sotthivirat, Saowapak
    2006 INTERNATIONAL SYMPOSIUM ON COMMUNICATIONS AND INFORMATION TECHNOLOGIES,VOLS 1-3, 2006, : 376 - +
  • [32] Effect of Cone-Beam Computed Tomography Field of View and Acquisition Frame on the Detection of Chemically Simulated Peri-Implant Bone Loss In Vitro
    Pinheiro, Lucas Rodrigues
    Scarfe, William C.
    de Oliveira Sales, Marcelo Augusto
    Gaia, Bruno Felipe
    Gonzalez Cortes, Arthur Rodriguez
    Cavalcanti, Marcelo Gusmao
    JOURNAL OF PERIODONTOLOGY, 2015, 86 (10) : 1159 - 1165
  • [33] Metal Artifact Reduction in Cone-Beam Computed Tomography for Ultrasound-Guided Cardiac Radioablation Using Protons
    Puvanasunthararajah, S.
    Camps, S.
    Wille, M.
    Ramachandran, P.
    Fontanarosa, D.
    MEDICAL PHYSICS, 2022, 49 (06) : E716 - E717
  • [34] Metal Artifact Reduction in Cone-Beam X-Ray Computed Tomography Using Statistical Iterative Reconstruction
    Aootaphao, Sorapong
    Pintavirooj, Chuchart
    Sotthivirat, Saowapak
    ECTI-CON 2008: PROCEEDINGS OF THE 2008 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY, VOLS 1 AND 2, 2008, : 493 - +
  • [35] More about accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography
    Dongyun Wang
    Andreas Künzel
    Vladimir Golubovic
    Ilya Mihatovic
    Gordon John
    Zhuofan Chen
    Jürgen Becker
    Frank Schwarz
    Clinical Oral Investigations, 2013, 17 : 1787 - 1788
  • [36] Accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography-is this correct?
    Sabour, Siamak
    Dastjerdi, Elahe Vahid
    Moezizadeh, Maryam
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (07) : 1785 - 1785
  • [37] More about accuracy of peri-implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography
    Wang, Dongyun
    Kuenzel, Andreas
    Golubovic, Vladimir
    Mihatovic, Ilya
    John, Gordon
    Chen, Zhuofan
    Becker, Juergen
    Schwarz, Frank
    CLINICAL ORAL INVESTIGATIONS, 2013, 17 (07) : 1787 - 1788
  • [38] Study of available bone for interforaminal implant treatment using cone-beam computed tomography
    Madrigal, Cristina
    Ortega, Ricardo
    Meniz, Cristina
    Lopez-Quiles, Juan
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2008, 13 (05): : E307 - E312
  • [39] A Comparison of Cone Beam Computed Tomography and Panoramic Radiography in the Detection of Mechanical Created Peri-implant Bone Defects
    Naje, Ahmed R.
    F-Al Drobie, Ban
    Falah, Ali
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2019, 7 (01): : 222 - 225
  • [40] Comparison of cone-beam computed tomography and digital panoramic radiography for detecting peri-implant alveolar bone changes using trabecular micro-structure analysis
    Magat, Guldane
    Oncu, Elif
    Ozcan, Sevgi
    Orhan, Kaan
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2022, 48 (01) : 41 - 49