Aorta in vivo parameter identification using an axial force constraint

被引:30
|
作者
Stålhand, J [1 ]
Klarbring, A [1 ]
机构
[1] Linkoping Univ, Dept Mech Engn, S-58183 Linkoping, Sweden
关键词
D O I
10.1007/s10237-004-0057-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
It was shown in a previous study by Stalhand et al. (2004) that both material and residual strain parameters for an artery can be identified noninvasively from an in vivo clinical pressure-diameter measurement. The only constraints placed on the model parameters in this previous study was a set of simple box constraints. More advanced constraints can also be utilized, however. These constraints restrict the model parameters implicitly by demanding the state of the artery to behave in a specified way. It has been observed in vitro that the axial force is nearly invariant to the pressure at the physiological operation point. In this paper, we study the possibility to include this behaviour as a constraint in the parameter optimization. The method is tested on an in vivo obtained pressure-diameter cycle for a 24-year-old human. Presented results show that the constrained parameter identification procedure proposed here can be used to obtain good results, and we believe that it may be applied to account for other observed behaviours as well.
引用
收藏
页码:191 / 199
页数:9
相关论文
共 50 条
  • [21] Parameter identification of spiral motor with force control response
    1600, Institute of Electrical Engineers of Japan (134):
  • [22] Determining the range of allowable axial force for the third-order Beam Constraint Model
    Ma, Fulei
    Chen, Guimin
    Hao, Guangbo
    MECHANICAL SCIENCES, 2018, 9 (01) : 71 - 79
  • [23] A constraint-based search algorithm for parameter identification of environmental models
    Gharari, S.
    Shafiei, M.
    Hrachowitz, M.
    Kumar, R.
    Fenicia, F.
    Gupta, H. V.
    Savenije, H. H. G.
    HYDROLOGY AND EARTH SYSTEM SCIENCES, 2014, 18 (12) : 4861 - 4870
  • [24] Identification of surface changes in diabetic aorta endothelial cells using peptide phage display library in vivo
    Romeo, G
    Frangioni, J
    Kazlauskas, A
    DIABETES, 2003, 52 : A477 - A477
  • [25] Vibration analysis of a cracked beam with axial force and crack identification
    Lu, Z. R.
    Liu, J. K.
    SMART STRUCTURES AND SYSTEMS, 2012, 9 (04) : 355 - 371
  • [26] PARAMETER VALIDATION USING CONSTRAINT OPTIMIZATION FOR MODELING AND SIMULATION
    Shao, Guodong
    McLean, Charles
    Brodsky, Alexander
    Ammann, Paul
    7TH INDUSTRIAL SIMULATION CONFERENCE 2009, 2009, : 21 - +
  • [27] Parameter Identification of the Vortex-Induced Vertical Force Model Using a New Adaptive PSO
    Tian, Xiaoxia
    Yan, Jingwen
    Xiao, Chi
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2018, 2018
  • [28] Inertial parameter identification using contact force information for an unknown object captured by a space manipulator
    Chu, Zhongyi
    Ma, Ye
    Hou, Yueyang
    Wang, Fengwen
    ACTA ASTRONAUTICA, 2017, 131 : 69 - 82
  • [29] Parameter identification of in vivo kinetic models: Limitations and challenges
    Heijnen, Joseph J.
    Verheijen, Peter J. T.
    BIOTECHNOLOGY JOURNAL, 2013, 8 (07) : 768 - +
  • [30] Geometric parameter identification of a dual-arm robot by using closed-chain constraint and optimization technique
    Yang, Wu-Te
    Li, Kuan-Lin
    Chan, Kuei-Yuan
    Lin, Pei-Chun
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2018, 232 (07) : 1294 - 1302