Capillary electrophoresis system with flow injection sample introduction and chemiluminescence detection on a chip platform

被引:64
|
作者
Huang, XJ
Pu, QS
Fang, ZL
机构
[1] Northeastern Univ, Analyt Sci Res Ctr, Shenyang 110006, Peoples R China
[2] Zhejiang Univ, Inst Microanalyt Syst, Hangzhou 310027, Peoples R China
关键词
D O I
10.1039/b008857i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A capillary electrophoresis (CE) system with chemiluminescence (CL) detection was combined with flow injection (FI) sample introduction on a chip platform. A falling-drop interface was applied to perform FI split-flow sample introduction while achieving electrical isolation from the CE high voltage. A tubular reservoir at the capillary outlet served as both the CL reaction and detection cell for the luminol-peroxide-metallic ion chemiluminescent reaction, with the luminol included in the separation buffer and CL reagent H2O2 continuously introduced into the outlet reservoir. An optical fiber was positioned within the outlet reservoir directly opposite, and 300 mum away from, the capillary outlet for collecting and transferring the generated CL to the PMT. The peak height signals and the separation efficiency were almost independent of the reagent flow-rate, making the system a robust one. The performance of the system was illustrated by the separation of Co(II) and Cu(II), achieving baseline separation in 60 s. Detection limits (3 sigma) were 1.25 x 10(-8) and 2.3 x 10(-6) mol dm(-3) for Co(II) and Cu(II), respectively. Peak height precision was 1.9% RSD (n = 9) at the 10(-7) mol dm(-3) Co level.
引用
收藏
页码:281 / 284
页数:4
相关论文
共 50 条
  • [31] INDIRECT CHEMILUMINESCENCE DETECTION IN CAPILLARY ELECTROPHORESIS
    LIAO, SY
    CHAO, YC
    WHANG, CW
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1995, 18 (10): : 667 - 669
  • [32] Detection of paracetamol by capillary electrophoresis with chemiluminescence detection
    Zhao, SL
    Bai, WL
    Yuan, HY
    Xiao, D
    ANALYTICA CHIMICA ACTA, 2006, 559 (02) : 195 - 199
  • [33] Chemiluminescence detection coupled to capillary electrophoresis
    Garcia-Campana, Ana M.
    Lara, Francisco J.
    Gamiz-Gracia, Laura
    Huertas-Perez, Jose F.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2009, 28 (08) : 973 - 986
  • [34] Analysis of antioxidants using a capillary electrophoresis with chemiluminescence detection system
    Tsukagoshi, Kazuhiko
    Taniguchi, Takehito
    Nakajima, Riichiro
    ANALYTICA CHIMICA ACTA, 2007, 589 (01) : 66 - 70
  • [35] Chemiluminescence detection in microchip capillary electrophoresis
    Hashimoto, M
    Tsukagoshi, K
    Nakajima, R
    Kondo, K
    Arai, A
    CHEMISTRY LETTERS, 1999, (08) : 781 - 782
  • [36] ELECTROGENERATED CHEMILUMINESCENCE DETECTION FOR CAPILLARY ELECTROPHORESIS
    GILMAN, SD
    SILVERMAN, CE
    EWING, AG
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1994, 6 (02) : 97 - 106
  • [37] Aeridinium chemiluminescence detection with capillary electrophoresis
    Ruberto, Michael A.
    Grayeski, Mary Lynn
    Analytical Chemistry, 1992, 64 (22)
  • [38] CAPILLARY ELECTROPHORESIS - AN INTEGRATED SYSTEM WITH A UNIQUE SPLIT-FLOW SAMPLE INTRODUCTION MECHANISM
    TEHRANI, J
    MACOMBER, R
    DAY, L
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1991, 14 (01): : 10 - 14
  • [39] Split injection: A simple introduction of subnanoliter sample volumes for chip electrophoresis
    Gaspar, A.
    Koczka, P. I.
    Carmona, H.
    Gomez, F. A.
    MICROCHEMICAL JOURNAL, 2011, 99 (02) : 180 - 185
  • [40] Flow injection analysis capillary electrophoresis system with hydrodynamic injection
    Kuban, P
    Pirmohammadi, R
    Karlberg, B