Model application research for liquid entrainment through ADS-4 pipe in AP1000

被引:4
|
作者
Meng, Zhaoming [1 ]
Ding, Lei [2 ]
Qiu, Zicheng [2 ]
Sun, Zhongning [1 ]
Yan, Changqi [1 ]
Qiu, Suizheng [3 ]
Su, Guanghui [3 ]
Tian, Wenxi [3 ]
机构
[1] Harbin Engn Univ, Fundamental Sci Nucl Safety & Simulat Technol Lab, Harbin 150001, Heilongjiang, Peoples R China
[2] Nucl Power Inst China, Chengdu 610041, Peoples R China
[3] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Sch Nucl Sci & Technol, 28 Xianning West Rd, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Onset entrainment model; Branch quality model; Liquid entrainment; ADS-4; SMALL BREAK; BRANCH; FLOW; TEE;
D O I
10.1016/j.anucene.2017.08.034
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Application research of two new liquid entrainment models for separately predicting the beginning of entrainment and branch entrainment quality is performed which is a continuation of previous experimental and theoretical studies on the entrainment at T-junction. The new onset entrainment model and branch quality model are developed on the basis of the scaling experiment for studying ADS-4 entrainment phenomenon in AP1000 plant, and the two new models along with previously published entrainment models are compared. The results show that previous models in the background of entrainment through a small break of primary pipe are not suitable for predicting the entrainment through a large size branch (e.g. ADS-4 pipe), while the two new models have a larger applicability. Also, the new entrainment models are written into the RELAP5 code, and then a typical 2-in SBLOCA transient in AP1000 is simulated separately by the modified RELAP5 and the original RELAP5 to further discuss the applicability of new models for the simulation of entrainment through ADS-4. The results show that the modified RELAP5 can get more reasonable simulation results. In view of original RELAP5 overestimated core coolant inventory, the modified RELAP5 can get a conservative core coolant inventory. Hence we can conclude that the new entrainment models are more suitable for the simulation of entrainment through ADS-4. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1043 / 1051
页数:9
相关论文
共 35 条
  • [31] Application case study of AP1000 automatic depressurization system (ADS) for reliability evaluation by GO-FLOW methodology
    Hashim, Muhammad
    Hidekazu, Yoshikawa
    Takeshi, Matsuoka
    Ming, Yang
    NUCLEAR ENGINEERING AND DESIGN, 2014, 278 : 209 - 221
  • [32] RELAP5/MOD3.4 calculation and model evaluation based on upper plenum entrainment experiment in AP1000
    Song, Gongle
    Zhang, Dalin
    Liu, Qiang
    Xiang, Yan
    Su, G. H.
    Tian, Wenxi
    Qiu, Suizheng
    ANNALS OF NUCLEAR ENERGY, 2020, 138
  • [33] RESEARCH ON THE SHAKING TABLE TEST MODEL OF PCS STORAGE TANK OF AP1000 NUCLEAR POWER ENGINEERING
    Xiong, Jie
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 2, 2017,
  • [34] Experimental research on the thermal stratification criteria and heat transfer model for the multi-holes steam ejection in IRWST of AP1000 plant
    Zhang, Yuhao
    Lu, Daogang
    Wang, Zhongyi
    Fu, Xiaoliang
    Cao, Qiong
    Yang, Yanhua
    Wu, Guanghao
    APPLIED THERMAL ENGINEERING, 2016, 107 : 1046 - 1056
  • [35] Ensemble-based sensitivity analysis of a Best Estimate Thermal Hydraulics model: Application to a Passive Containment Cooling System of an AP1000 Nuclear Power Plant
    Di Maio, Francesco
    Nicola, Giancarlo
    Zio, Enrico
    Yu, Yu
    ANNALS OF NUCLEAR ENERGY, 2014, 73 : 200 - 210