Masticatory fatigue, fracture resistance, and marginal discrepancy of ceramic partial crowns with and without coverage of compromised cusps

被引:0
|
作者
Stappert, Christian F. J. [1 ,2 ]
Abe, Pia [2 ]
Kurths, Volker [2 ]
Gerds, Thomas [2 ]
Strub, Joerg R. [2 ]
机构
[1] NYU, Coll Dent, Dept Biomat & Biomimet, Dept Periodontol & Implant Dent, New York, NY 10010 USA
[2] Univ Freiburg, Dept Prosthodont, Freiburg, Germany
来源
JOURNAL OF ADHESIVE DENTISTRY | 2008年 / 10卷 / 01期
关键词
fracture resistance; marginal discrepancy; partial coverage restoration; ceramic; fatigue;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate preparation designs of compromised cusps and whether or not they influence masticatory fatigue, fracture resistance, and marginal discrepancy of ceramic partial-coverage restorations (PCRs) luted on mandibular molars. Materials and Methods: Sixty-four caries-free molars were equally divided into four groups. Control group NP received no preparation (NP). Group B-IN received a basic inlay (IN) preparation with buccal (B) cusp conservation and occlusal reduction of both lingual cusps. Group B-ON was prepared in the same way, except buccal cusps were prepared with an angle of 45 degrees to the occlusal plane (buccal onlay). Group B-OV preparation was similar to group B-ON, but buccal cusps received a further shoulder preparation on the buccal aspect (buccal overlap). Forty-eight all-ceramic IPS e.max Press PCRs were fabricated and luted adhesively. Specimens underwent mouth-motion fatigue (1.2 million cycles, 1.6 Hz, 49 N) and 5500 thermal cycles (50 degrees C/550 degrees C). Fracture patterns were observed. Surviving specimens were loaded until fracture. Marginal discrepancies were examined. Results: Only one specimen of group B-ON fractured during fatigue. Median fracture loads (N) [IQR=X-.25-X-.75]: group NP = 1604 N [1182-1851 N], group B-IN = 1307 N [1262-1587N], group B-ON = 1396 N [817-1750N], group B-OV = 1205 N (1096-1542N]. No significant differences in fracture resistance were found between restored molars and unprepared teeth (p >= 0.18). Different preparation designs showed no significant influence on PCR fracture resistance. Mouth-motion fatigue caused a significanty decrease of marginal accuracy in groups B-IN (p = 0.009) and B-ON (p = 0.008). Marginal discrepancy values of groups B-IN and B-OV were significantly different after fatigue (p = 0.045). Conclusion: Ceramic coverage of compromised cusps did not demonstrate an increase of fracture resistance after fatigue when compared to less invasive partial-coverage restorations. However, enhanced exposure of restoration margins to occlusal wear could result in more extensive marginal discrepancies.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 21 条
  • [1] All-ceramic partial coverage restorations on natural molars. Masticatory fatigue loading and fracture resistance
    Stappert, Christian F. J.
    Guess, Petra C.
    Chitmongkolsuk, Somsak
    Gerds, Thomas
    Strub, Jorg R.
    AMERICAN JOURNAL OF DENTISTRY, 2007, 20 (01): : 21 - 26
  • [2] Fracture resistance of partial and complete coverage veneers and ceramic crowns for maxillary central incisors
    Jurado, Carlos A.
    Mekled, Salwa
    Abuhammoud, Salahaldeen
    Azpiazu-Flores, Francisco X.
    Vegh, Daniel
    Wang, Ting
    Morton, Dean
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (02): : 420e1 - 420e6
  • [3] Partial ceramic crowns:: Influence of ceramic thickness, preparation design and luting material on fracture resistance and marginal integrity in vitro
    Federlin, M.
    Krifka, S.
    Herpich, M.
    Hiller, K-A
    Schmalz, G.
    OPERATIVE DENTISTRY, 2007, 32 (03) : 251 - 260
  • [4] Comparison of full and partial coverage crowns with CAD/CAM leucite reinforced ceramic blocks on fracture resistance and fractographic analysis
    Jurado, Carlos A.
    Mourad, Firas
    Cortes Trevino, Daniel Alberto
    Gouveia, Diogo N.
    Hyer, Jared
    Elgreatly, Amira
    Mahrous, Ahmed M.
    Garcia-Godoy, Franklin
    Tsujimoto, Akimasa
    DENTAL MATERIALS JOURNAL, 2022, 41 (02) : 295 - 301
  • [5] Comparison of full and partial coverage crowns with CAD/CAM leucite reinforced ceramic blocks on fracture resistance and fractographic analysis
    Jurado, Carlos A.
    Mourad, Firas
    Cortes Trevino, Daniel Alberto
    Gouveia, Diogo N.
    Hyer, Jared
    Elgreatly, Amira
    Mahrous, Ahmed M.
    Garcia-Godoy, Franklin
    Tsujimoto, Akimasa
    Dental Materials Journal, 2022, 41 (02): : 295 - 301
  • [6] Influence of Ceramic Thickness and Ceramic Materials on Fracture Resistance of Posterior Partial Coverage Restorations
    Bakeman, E. M.
    Rego, N.
    Chaiyabutr, Y.
    Kois, J. C.
    OPERATIVE DENTISTRY, 2015, 40 (02) : 211 - 217
  • [7] Influence of Thermomechanical Fatigue Loading on the Fracture Resistance of All-ceramic Posterior Crowns
    Senyilmaz, Dilek Pinar
    Canay, Senay
    Heydecke, Guido
    Strub, Joerg Rudolf
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2010, 18 (02): : 50 - 54
  • [8] Fracture Resistance of Chairside CAD/CAM Lithium Disilicate- reinforced Ceramic Occlusal Veneers With and Without Margin and Full Coverage Crowns
    Jurado, C. A.
    Lee, D.
    Ramirez, P.
    Cortes-Trevino, D. A.
    Tsujimoto, A.
    OPERATIVE DENTISTRY, 2024, 49 (01) : 84 - 90
  • [9] The effect of different materials and cavity designs on fracture resistance of ceramic partial coverage
    Attia, Mahmoud
    Fahmy, Nadia
    Shaker, Atef
    Salah, Tarek
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2024, 36 (10) : 1459 - 1465
  • [10] All-ceramic partial coverage premolar restorations. Cavity preparation design, reliability and fracture resistance after fatigue
    Stappert, CFJ
    Guess, PC
    Gerds, T
    Strub, JR
    AMERICAN JOURNAL OF DENTISTRY, 2005, 18 (04): : 275 - 280