Tetralogy of Fallot: 3D Velocity-encoded MR Imaging for Evaluation of Right Ventricular Valve Flow and Diastolic Function in Patients after Correction

被引:44
|
作者
van der Hulst, Annelies E. [1 ]
Westenberg, Jos J. M. [2 ]
Kroft, Lucia J. M. [2 ]
Bax, Jeroen J. [3 ]
Blom, Nico A. [1 ]
de Roos, Albert [2 ]
Roest, Arno A. W. [1 ]
机构
[1] Leiden Univ Med Ctr, Div Pediat Cardiol, Dept Pediat, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ Med Ctr, Dept Radiol, NL-2300 RC Leiden, Netherlands
[3] Leiden Univ Med Ctr, Dept Cardiol, NL-2300 RC Leiden, Netherlands
关键词
MAGNETIC-RESONANCE; PULMONARY REGURGITATION; RESTRICTIVE PHYSIOLOGY; REPAIRED TETRALOGY; FOLLOW-UP; RECOMMENDATIONS; QUANTIFICATION; CHILDREN; ACCURATE;
D O I
10.1148/radiol.10092269
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate three-dimensional (3D) velocity-encoded (VE) magnetic resonance (MR) imaging, as compared with two-dimensional (2D) VE MR imaging, for assessment of pulmonary valve (PV) and tricuspid valve (TV) flow, with planimetry as the reference standard, and to evaluate diastolic function in patients with a corrected tetralogy of Fallot (TOF). Materials and Methods: Local institutional review board approval was obtained, and patients or their parents gave informed consent. Twenty-five patients with a corrected TOF (12 male, 13 female; mean age, 13.1 years +/- 2.7 [standard deviation]; age range, 8-18 years) and 19 control subjects (12 male, seven female; mean age, 14.1 years +/- 2.4; age range, 8-18 years) underwent planimetric MR imaging, 2D VE MR imaging, and 3D VE MR imaging for TV and PV flow evaluation. For evaluation of diastolic function, PV and TV flow were summated. Data were analyzed by using linear regression analysis, paired and unpaired t testing, and Bland-Altman plots. Results: Strong correlations between the 2D VE MR and 3D VE MR measurements of PV flow (for forward flow: r = 0.87, P < .01; for backward fl ow: r = 0.97, P < .01) were observed. With PV effective fl ow as a reference, 3D TV effective fl ow measurements were more accurate than 2D TV effective fl ow measurements: In patients, the mean 2D TV effective fl ow versus 2D PV effective fl ow difference was 17.6 mL +/- 11 (P < .001), and the mean 3D TV effective fl ow versus 3D PV effective fl ow difference was - 1.2 mL +/- 4.7 (P = .22). Diastolic functional impairment in patients could be detected at 3D VE MR imaging diastolic assessment. Conclusion: Three-dimensional VE MR imaging is accurate for PV fl ow assessment and is more accurate than 2D VE MR imaging for TV fl ow evaluation. Assessment of diastolic function with 3D VE MR imaging can facilitate ongoing research of diastolic dysfunction in patients with a corrected TOF.
引用
收藏
页码:724 / 734
页数:11
相关论文
共 50 条
  • [41] Right and left ventricular function and flow quantification in pediatric patients with repaired tetralogy of Fallot using four-dimensional flow magnetic resonance imaging
    Yao, Xiaofen
    Hu, Liwei
    Peng, Yafeng
    Feng, Fei
    Ouyang, Rongzhen
    Xie, Weihui
    Wang, Qian
    Sun, Aimin
    Zhong, Yumin
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [42] Evaluation of right ventricular function in patients with tetralogy of Fallot using the myocardial performance index and isovolumic acceleration: a comparison with cardiac magnetic resonance imaging
    Koca, Bulent
    Oztunc, Funda
    GulerEroglu, Ayse
    Gokalp, Selman
    Dursen, Memduh
    Yilmaz, Ravza
    CARDIOLOGY IN THE YOUNG, 2014, 24 (03) : 422 - 429
  • [43] Volume overload impact on 3D right ventricular shape and strain: comparative analysis of tetralogy of Fallot and atrial septal defect patients
    Moceri, P.
    Duchateau, N.
    Baudouy, D.
    Squara, F.
    Ferrari, E.
    Sermesant, M.
    EUROPEAN HEART JOURNAL, 2018, 39 : 366 - 367
  • [44] Right ventricular function in patients after acute myocardial infarction assessed with phase contrast MR velocity mapping encoded in three directions
    Kayser, HWM
    van der Geest, RJ
    van der Wall, EE
    Duchateau, C
    de Roos, A
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 11 (05): : 471 - 475
  • [45] Dynamic Right Ventricular Function Assessment by Real-Time 3D Echography in Combination with Semiautomatic Endocardial Detection in Adults with Corrected Tetralogy of Fallot: Comparison with Magnetic Resonance Imaging
    Iriart, Xavier
    Montaudon, Michel
    Lafitte, Stephane
    Bougteb, Hanane
    Laurent, Francois
    Reant, Patricia
    Balbach, Thomas
    Thambo, Jean-Benoit
    CIRCULATION, 2008, 118 (18) : S910 - S910
  • [46] Comprehensive echocardiographic assessment of right ventricular function, pulmonary arterial elastic properties and ventricular-vascular coupling in adult patients with repaired tetralogy of fallot: clinical significance of 3D derived indices
    Vitarelli, Antonio
    Miraldi, Fabio
    Capotosto, Lidia
    Galea, Nicola
    Francone, Marco
    Marchitelli, Livia
    Viceconte, Nicola
    Smaldone, Costantino
    Mangieri, Enrico
    Nguyen, Bich Lien
    Tanzilli, Gaetano
    Mancone, Massimo
    Al-Kindy, Sulaiman
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2023, 39 (09): : 1631 - 1641
  • [47] Comprehensive echocardiographic assessment of right ventricular function, pulmonary arterial elastic properties and ventricular-vascular coupling in adult patients with repaired tetralogy of fallot: clinical significance of 3D derived indices
    Antonio Vitarelli
    Fabio Miraldi
    Lidia Capotosto
    Nicola Galea
    Marco Francone
    Livia Marchitelli
    Nicola Viceconte
    Costantino Smaldone
    Enrico Mangieri
    Bich Lien Nguyen
    Gaetano Tanzilli
    Massimo Mancone
    Sulaiman Al-Kindy
    The International Journal of Cardiovascular Imaging, 2023, 39 : 1631 - 1641
  • [48] Evaluation of Global and Regional Right Ventricular Systolic Function in Patient Prosthesis Mismatch after Mitral Valve Replacement using Velocity Vector Imaging
    Tugcu, Aylin
    Tayyareci, Yelda
    Ylldirimturk, Ozlem
    Aytekin, Saide
    CIRCULATION, 2008, 118 (18) : S1001 - S1001
  • [49] The Assessment of Regional Right Ventricular Function in Patients After Repaired Tetralogy of Fallot: Myocardial Strain Measurement by Speckle Tracking Echocardiography in Comparison With Tagging by Cardiac Magnetic Resonance Imaging
    Lyseggen, Erik
    Wald, Rachel
    Redington, Andrew N.
    Silversides, Candice K.
    Siu, Samuel C.
    Provost, Yves
    Oechslin, Erwin N.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A362 - A362
  • [50] 2D Echocardiographic Evaluation of Right Ventricular Function Correlates With 3D Volumetric Models in Cardiac Surgery Patients
    Magunia, Harry
    Schmid, Eckhard
    Hilberath, Jan N.
    Haeberle, Leo
    Grasshoff, Christian
    Schlensak, Christian
    Rosenberger, Peter
    Nowak-Machen, Martina
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2017, 31 (02) : 595 - 601