Tetralogy of Fallot: 3D Velocity-encoded MR Imaging for Evaluation of Right Ventricular Valve Flow and Diastolic Function in Patients after Correction

被引:44
|
作者
van der Hulst, Annelies E. [1 ]
Westenberg, Jos J. M. [2 ]
Kroft, Lucia J. M. [2 ]
Bax, Jeroen J. [3 ]
Blom, Nico A. [1 ]
de Roos, Albert [2 ]
Roest, Arno A. W. [1 ]
机构
[1] Leiden Univ Med Ctr, Div Pediat Cardiol, Dept Pediat, NL-2300 RC Leiden, Netherlands
[2] Leiden Univ Med Ctr, Dept Radiol, NL-2300 RC Leiden, Netherlands
[3] Leiden Univ Med Ctr, Dept Cardiol, NL-2300 RC Leiden, Netherlands
关键词
MAGNETIC-RESONANCE; PULMONARY REGURGITATION; RESTRICTIVE PHYSIOLOGY; REPAIRED TETRALOGY; FOLLOW-UP; RECOMMENDATIONS; QUANTIFICATION; CHILDREN; ACCURATE;
D O I
10.1148/radiol.10092269
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate three-dimensional (3D) velocity-encoded (VE) magnetic resonance (MR) imaging, as compared with two-dimensional (2D) VE MR imaging, for assessment of pulmonary valve (PV) and tricuspid valve (TV) flow, with planimetry as the reference standard, and to evaluate diastolic function in patients with a corrected tetralogy of Fallot (TOF). Materials and Methods: Local institutional review board approval was obtained, and patients or their parents gave informed consent. Twenty-five patients with a corrected TOF (12 male, 13 female; mean age, 13.1 years +/- 2.7 [standard deviation]; age range, 8-18 years) and 19 control subjects (12 male, seven female; mean age, 14.1 years +/- 2.4; age range, 8-18 years) underwent planimetric MR imaging, 2D VE MR imaging, and 3D VE MR imaging for TV and PV flow evaluation. For evaluation of diastolic function, PV and TV flow were summated. Data were analyzed by using linear regression analysis, paired and unpaired t testing, and Bland-Altman plots. Results: Strong correlations between the 2D VE MR and 3D VE MR measurements of PV flow (for forward flow: r = 0.87, P < .01; for backward fl ow: r = 0.97, P < .01) were observed. With PV effective fl ow as a reference, 3D TV effective fl ow measurements were more accurate than 2D TV effective fl ow measurements: In patients, the mean 2D TV effective fl ow versus 2D PV effective fl ow difference was 17.6 mL +/- 11 (P < .001), and the mean 3D TV effective fl ow versus 3D PV effective fl ow difference was - 1.2 mL +/- 4.7 (P = .22). Diastolic functional impairment in patients could be detected at 3D VE MR imaging diastolic assessment. Conclusion: Three-dimensional VE MR imaging is accurate for PV fl ow assessment and is more accurate than 2D VE MR imaging for TV fl ow evaluation. Assessment of diastolic function with 3D VE MR imaging can facilitate ongoing research of diastolic dysfunction in patients with a corrected TOF.
引用
收藏
页码:724 / 734
页数:11
相关论文
共 50 条
  • [1] Clinical application of 3D velocity-encoded magnetic resonance imaging: a new tool for the assessment of tricuspid and pulmonary valve flow and diastolic function of the right ventricle in patients after correction of Tetralogy of Fallot
    Annelies E van der Hulst
    Jos JM Westenberg
    Lucia JM Kroft
    Jeroen J Bax
    Nico A Blom
    Albert de Roos
    Arno AW Roest
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [2] Assessment of diastolic heart failure by 3D velocity-encoded MR Imaging with retrospective valve tracking
    Martin Hadamitzky
    Monika Hofmann
    Nadine Kirchhartz
    Liselotte Goedel-Meinen
    Stefan Martinoff
    Albert Schömig
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [3] Mitral Valve and Tricuspid Valve Blood Flow: Accurate Quantification with 3D Velocity-encoded MR Imaging with Retrospective Valve Tracking
    Westenberg, Jos J. M.
    Roes, Stijntje D.
    Marsan, Nina Ajmone
    Binnendijk, Nico M. J.
    Doornbos, Joost
    Bax, Jeroen J.
    Reiber, Johan H. C.
    De Roos, Albert
    van der Geest, Robert J.
    RADIOLOGY, 2008, 249 (03) : 792 - 800
  • [4] Tricuspid valve magnetic resonance imaging phase contrast velocity-encoded flow quantification for follow up of tetralogy of Fallot
    Greenberg, S. Bruce
    Shah, Chetan C.
    Bhutta, Sadaf T.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2008, 24 (08): : 861 - 865
  • [5] Tricuspid valve magnetic resonance imaging phase contrast velocity-encoded flow quantification for follow up of tetralogy of Fallot
    S. Bruce Greenberg
    Chetan C. Shah
    Sadaf T. Bhutta
    The International Journal of Cardiovascular Imaging, 2008, 24 : 861 - 865
  • [6] Right ventricular function after pulmonary valve replacement in patients with tetralogy of Fallot
    van Straten, A
    Vliegen, HW
    Hazekamp, MG
    Bax, JJ
    Schoof, PH
    Ottenkamp, J
    van der Wall, EE
    de Roos, A
    RADIOLOGY, 2004, 233 (03) : 824 - 829
  • [7] Corrected Tetralogy of Fallot: Comparison of Tissue Doppler Imaging and Velocity-encoded MR for Assessment of Performance and Temporal Activation of Right Ventricle
    van der Hulst, Annelies E.
    Roest, Arno A. W.
    Delgado, Victoria
    Kroft, Lucia J. M.
    Holman, Eduard R.
    Blom, Nico A.
    Bax, Jeroen J.
    de Roos, Albert
    Westenberg, Jos J. M.
    RADIOLOGY, 2011, 260 (01) : 88 - 97
  • [8] Evaluation of right ventricular function in operated tetralogy of Fallot patients with tissue Doppler imaging before and after pulmonary valve replacement
    Gursu, Hazim Alper
    Varan, Birgul
    Erdogan, Ilkay
    Ozkan, Murat
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 26 (03): : 359 - 364
  • [9] RIGHT-VENTRICULAR DIASTOLIC FUNCTION IN CHILDREN WITH SURGICALLY CORRECTED TETRALOGY OF FALLOT AND PULMONARY REGURGITATION - VOLUMETRIC EVALUATION WITH MR VELOCITY MAPPING
    HELBING, WA
    NIEZEN, RA
    VANDERGEEST, RJ
    MEINESZ, S
    DEROOS, A
    RADIOLOGY, 1995, 197 : 335 - 335
  • [10] Evaluation of Right Ventricular Function by Using Tissue Doppler Imaging in Patients after Repair of Tetralogy of Fallot
    Cetin, Ilker
    Tokel, Kuersad
    Varan, Birguel
    Orun, Utku
    Aslamaci, Sait
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (08): : 950 - 957