Model-based vs hybrid iterative reconstruction technique in ultralow-dose submillisievert CT colonography

被引:17
|
作者
Lambert, L. [1 ]
Ourednicek, P. [2 ]
Jahoda, J. [1 ]
Lambertova, A. [3 ]
Danes, J. [1 ]
机构
[1] Charles Univ Prague, Fac Med 1, Dept Radiol, Prague, Czech Republic
[2] St Annes Univ Hosp, Dept Imaging Methods, Brno, Czech Republic
[3] Charles Univ Prague, Fac Med 1, Dept Psychiat, Prague, Czech Republic
来源
BRITISH JOURNAL OF RADIOLOGY | 2015年 / 88卷 / 1048期
关键词
COLORECTAL POLYPS; IMAGE QUALITY; CANCER; FEASIBILITY; STANDARD; LESIONS;
D O I
10.1259/bjr.20140667
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare image quality of different reconstruction techniques in submillisievert ultralow-dose CT colonography (CTC) and to correlate colonic findings with subsequent optical colonoscopy. Methods: 58 patients underwent ultralow-dose CTC. The images were reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (HIR) or model-based iterative reconstruction (MBIR) techniques. In each segment, endoluminal noise (expressed as standard deviation of endoluminal density) was measured and image quality was rated on a five-point Likert scale by two independent readers. Colonic lesions were evaluated in consensus and correlated with subsequent optical colonoscopy where possible. Results: The estimated radiation dose was 0.41 +/- 0.05mSv for the supine and 0.42 +/- 0.04mSv for the prone acquisitions. In the endoluminal view, the image quality was rated better in HIR, whereas better scores were obtained in MBIR in the cross-sectional view, where the endoluminal noise was the lowest (p < 0.0001). Five (26%) polyps were not identified using both computer-aided detection and endoluminal inspection in FBP images vs only one (5%) in MBIR and none in HIR images. Conclusion: This study showed that in submillisievert ultralow-dose CTC, the image quality for the endoluminal view is better when HIR is used, whereas MBIR yields superior images for the cross-sectional view. The inferior quality of images reconstructed with FBP may result in decreased detection of colonic lesions. Advances in knowledge: Radiation dose from CTC can be safely reduced <1mSv for both positions when iterative reconstruction is used. MBIR provides better image quality in the cross-sectional view and HIR in the endoluminal view.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Sub-milliSievert ultralow-dose CT colonography with iterative model reconstruction technique
    Lambert, Lukas
    Ourednicek, Petr
    Briza, Jan
    Giepmans, Walter
    Jahoda, Jiri
    Hruska, Lukas
    Danes, Jan
    PEERJ, 2016, 4
  • [2] Submilisievert ultralow-dose CT colonography using iterative reconstruction technique: a feasibility study
    Lambert, Lukas
    Danes, Jan
    Jahoda, Jiri
    Masek, Martin
    Lisy, Jiri
    Ourednicek, Petr
    ACTA RADIOLOGICA, 2015, 56 (05) : 517 - 525
  • [3] Model-Based Iterative Reconstruction Technique for Ultralow-Dose Chest CT Comparison of Pulmonary Nodule Detectability With the Adaptive Statistical Iterative Reconstruction Technique
    Katsura, Masaki
    Matsuda, Izuru
    Akahane, Masaaki
    Yasaka, Koichiro
    Hanaoka, Shohei
    Akai, Hiroyuki
    Sato, Jiro
    Kunimatsu, Akira
    Ohtomo, Kuni
    INVESTIGATIVE RADIOLOGY, 2013, 48 (04) : 206 - 212
  • [4] Model-Based Iterative Reconstruction Technique for Ultralow-Dose Computed Tomography of the Lung A Pilot Study
    Yamada, Yoshitake
    Jinzaki, Masahiro
    Tanami, Yutaka
    Shiomi, Eisuke
    Sugiura, Hiroaki
    Abe, Takayuki
    Kuribayashi, Sachio
    INVESTIGATIVE RADIOLOGY, 2012, 47 (08) : 482 - 489
  • [5] Abdominal CT With Model-Based Iterative Reconstruction (MBIR): Initial Results of a Prospective Trial Comparing Ultralow-Dose With Standard-Dose Imaging
    Pickhardt, Perry J.
    Lubner, Meghan G.
    Kim, David H.
    Tang, Jie
    Ruma, Julie A.
    del Rio, Alejandro Munoz
    Chen, Guang-Hong
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) : 1266 - 1274
  • [6] Usefulness of Ultralow-Dose (Submillisievert) Chest CT Using Iterative Reconstruction for Initial Evaluation of Sharp Fish Bone Esophageal Foreign Body
    Kim, Eun Young
    Min, Young Gi
    Bista, Anjali Basnyat
    Park, Kyung Joo
    Kang, Doo Kyoung
    Sun, Joo Sung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (05) : 985 - 990
  • [7] Emphysema Quantification Using Ultralow-Dose CT With Iterative Reconstruction and Filtered Back Projection
    Nishio, Mizuho
    Koyama, Hisanobu
    Ohno, Yoshiharu
    Negi, Noriyuki
    Seki, Shinichiro
    Yoshikawa, Takeshi
    Sugimura, Kazuro
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (06) : 1184 - 1192
  • [8] Ultralow-Dose CT of the Craniofacial Bone for Navigated Surgery Using Adaptive Statistical Iterative Reconstruction and Model-Based Iterative Reconstruction: 2D and 3D Image Quality
    Widmann, Gerlig
    Schullian, Peter
    Gassner, Eva-Maria
    Hoermann, Romed
    Bale, Reto
    Puelacher, Wolfgang
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) : 563 - 569
  • [9] Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique
    Masaki Katsura
    Izuru Matsuda
    Masaaki Akahane
    Jiro Sato
    Hiroyuki Akai
    Koichiro Yasaka
    Akira Kunimatsu
    Kuni Ohtomo
    European Radiology, 2012, 22 : 1613 - 1623
  • [10] Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique
    Katsura, Masaki
    Matsuda, Izuru
    Akahane, Masaaki
    Sato, Jiro
    Akai, Hiroyuki
    Yasaka, Koichiro
    Kunimatsu, Akira
    Ohtomo, Kuni
    EUROPEAN RADIOLOGY, 2012, 22 (08) : 1613 - 1623