Model-Based Iterative Reconstruction Technique for Ultralow-Dose Computed Tomography of the Lung A Pilot Study

被引:125
|
作者
Yamada, Yoshitake
Jinzaki, Masahiro [1 ]
Tanami, Yutaka
Shiomi, Eisuke [2 ]
Sugiura, Hiroaki
Abe, Takayuki [3 ]
Kuribayashi, Sachio
机构
[1] Keio Univ, Dept Diagnost Radiol, Sch Med, Shinjuku Ku, Tokyo 1608582, Japan
[2] Natl Def Med Coll Hosp, Dept Radiol, Saitama, Japan
[3] Keio Univ, Clin Res Ctr, Sch Med, Tokyo 1608582, Japan
关键词
iterative reconstruction; chest; CT; nodule; image quality; FILTERED BACK-PROJECTION; IMAGE-QUALITY; PULMONARY NODULES; CHEST CT; OBSERVER PERFORMANCE; REDUCTION;
D O I
10.1097/RLI.0b013e3182562a89
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to assess the effectiveness of a model-based iterative reconstruction (MBIR) in improving image quality and diagnostic performance of ultralow-dose computed tomography (ULDCT) of the lung. Materials and Methods: The institutional review board approved this study, and all patients provided written informed consent. Fifty-two patients underwent low-dose computed tomography (LDCT) (screening-dose, 50 mAs) and ULDCT (4 mAs) of the lung simultaneously. The LDCT images were reconstructed with filtered back projection (LDCT-FBP images) and ULDCT images were reconstructed with both MBIR (ULDCT-MBIR images) and FBP (ULDCT-FBP images). On all the 156 image series, objective image noise was measured in the thoracic aorta, and 2 blinded radiologists independently assessed subjective image quality. Another 2 blinded radiologists independently evaluated the ULDCT-MBIR and ULDCT-FBP images for the presence of noncalcified and calcified pulmonary nodules; LDCT-FBP images served as the reference. Paired t test, Wilcoxon signed rank sum test, and free-response receiver-operating characteristic analysis were used for statistical analysis of the data. Results: Compared with LDCT-FBP and ULDCT-FBP, ULDCT-MBIR had significantly reduced objective noise (both P < 0.001). Subjective noise on the ULDCT-MBIR images was comparable with that on the LDCT-FBP images but lower than that on the ULDCT-FBP images (P < 0.001). Artifacts on ULDCT-MBIR images were more numerous than those on the LDCT-FBP images (P = 0.007) but fewer than those on the ULDCT-FBP images (P < 0.001). Compared with the LDCT-FBP images, ULDCT-MBIR and ULDCT-FBP images showed reduced image sharpness (both P < 0.001). All the ULDCT-MBIR images showed a blotchy pixelated appearance; however, the performance of ULDCT-MBIR was significantly superior to that of ULDCT-FBP for the detection of noncalcified pulmonary nodules (P = 0.002). The average true-positive fractions for significantly sized noncalcified nodules (>= 4 mm) and small noncalcified nodules (<4 mm) on the ULDCT-MBIR images were 0.944 and 0.884, respectively, when LDCT-FBP images were used as reference. All of the calcified nodules were detected by both the observers on both the ULDCT-MBIR and ULDCT-FBP images. Conclusion: As compared with FBP, MBIR enables significant reduction of the image noise and artifacts and also better detection of noncalcified pulmonary nodules on ULDCT of the lung. Compared with LDCT-FBP images, ULDCT-MBIR images showed significantly reduced objective noise and comparable subjective image noise. Almost all of the noncalcified nodules and all of the calcified nodules could be detected on the ULDCT-MBIR images, when LDCT-FBP images were used as the reference.
引用
收藏
页码:482 / 489
页数:8
相关论文
共 50 条
  • [1] Model-based vs hybrid iterative reconstruction technique in ultralow-dose submillisievert CT colonography
    Lambert, L.
    Ourednicek, P.
    Jahoda, J.
    Lambertova, A.
    Danes, J.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1048):
  • [2] Model-Based Iterative Reconstruction Technique for Ultralow-Dose Chest CT Comparison of Pulmonary Nodule Detectability With the Adaptive Statistical Iterative Reconstruction Technique
    Katsura, Masaki
    Matsuda, Izuru
    Akahane, Masaaki
    Yasaka, Koichiro
    Hanaoka, Shohei
    Akai, Hiroyuki
    Sato, Jiro
    Kunimatsu, Akira
    Ohtomo, Kuni
    INVESTIGATIVE RADIOLOGY, 2013, 48 (04) : 206 - 212
  • [3] Ultralow-Dose Abdominal Computed Tomography: Comparison of 2 Iterative Reconstruction Techniques in a Prospective Clinical Study
    Khawaja, Ranish Deedar Ali
    Singh, Sarabjeet
    Blake, Michael
    Harisinghani, Mukesh
    Choy, Gary
    Karosmanoglu, Ali
    Padole, Atul
    Pourjabbar, Saravenaz
    Do, Synho
    Kalra, Mannudeep K.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (04) : 489 - 498
  • [4] Model-based iterative reconstruction in paediatric head computed tomography: a pilot study on dose reduction in children
    Atri, Pardeep K.
    Sodhi, Kushaljit S.
    Bhatia, Anmol
    Saxena, Akshay K.
    Khandelwal, Niranjan
    Singhi, Pratibha
    POLISH JOURNAL OF RADIOLOGY, 2021, 86 : E504 - E510
  • [5] Sub-milliSievert ultralow-dose CT colonography with iterative model reconstruction technique
    Lambert, Lukas
    Ourednicek, Petr
    Briza, Jan
    Giepmans, Walter
    Jahoda, Jiri
    Hruska, Lukas
    Danes, Jan
    PEERJ, 2016, 4
  • [6] Submilisievert ultralow-dose CT colonography using iterative reconstruction technique: a feasibility study
    Lambert, Lukas
    Danes, Jan
    Jahoda, Jiri
    Masek, Martin
    Lisy, Jiri
    Ourednicek, Petr
    ACTA RADIOLOGICA, 2015, 56 (05) : 517 - 525
  • [7] A comparison of Model-Based Iterative Reconstruction (MBIR) technique with standard Dose Computed Tomography of Thorax in the follow up of lung nodules
    O'Mahony, A. M.
    James, K.
    Chawke, L.
    Moore, N.
    Maher, M. M.
    Kennedy, P.
    Murphy, K. P.
    Khan, K. A. Ali
    Murphy, D.
    Henry, M. T.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2017, 186 : S414 - S415
  • [8] A comparison of Model-Based Iterative Reconstruction (MBIR) technique with standard Dose Computed Tomography of Thorax in the follow up of lung nodules
    O'Mahony, Ann
    James, Karl
    Chawke, Liam
    Moore, Niamh
    Maher, Michael M.
    Murphy, Kevin P.
    Khan, Kashif Ali
    Kennedy, Marcus P.
    Murphy, Desmond
    Henry, Michael T.
    EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [9] A comparison of Model-Based Iterative Reconstruction (MBIR) technique with standard Dose Computed Tomography of Thorax in the follow up of lung nodules
    O'Mahony, A. M.
    James, K.
    Chawke, L.
    Moore, N.
    Maher, M. M.
    Kennedy, M. P.
    Murphy, K. P.
    Khan, K. A. Ali
    Murphy, D.
    Henry, M. T.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2017, 186 (SUPPL 10) : S414 - S415
  • [10] A prospective study on the use of ultralow-dose computed tomography with iterative reconstruction for the follow-up of patients liver and renal abscess
    Seo, Nieun
    Park, Mi-Suk
    Choi, Jun Yong
    Yeom, Joon-Sup
    Kim, Myeong-Jin
    Chung, Yong Eun
    Ku, Nam Su
    PLOS ONE, 2021, 16 (02):