A new chemical etchant for the development of alpha tracks in CR-39 solid state nuclear track detector

被引:12
|
作者
Chavan, Vivek [1 ]
Kalsi, P. C. [2 ]
Hong, Seung-Woo [1 ]
Manchanda, V. K. [2 ]
机构
[1] Sungkyunkwan Univ, Dept Phys, Suwon, South Korea
[2] Bhabha Atom Res Ctr, Radiochem Div, Mumbai 400085, Maharashtra, India
基金
新加坡国家研究基金会;
关键词
CR-39; New chemical etchant; Bulk and track etch rates; Detection efficiency; TRANSPORT; MOLECULES; PARTICLE;
D O I
10.1016/j.nimb.2019.10.033
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Chemical etching is an important step for enlargement of latent tracks in solid state nuclear track detectors (SSNTD). In the etching process, bulk and track etch rates are determined by various parameters, which decide the sensitivity and efficiency of the track detector. Thus, determination of the etching parameters is essential in introducing a new chemical etchant. For the enlargement of latent tracks in CR-39, chemical etching is usually carried out at temperatures of 60-70 degrees C by using 6-6.5 N concentrations of alkali like NaOH or KOH. In the present work, a mixture of 8 g NaOH in 25 mL water and 25 mL ethanolamine as an etchant at 70 degrees C was found to be very effective in the enlargement of alpha tracks in CR-39 SSNTD. The diameters of alpha tracks resulting from this new etchant are found to be a quadratic function of the etching time, whereas those from the standard etchant are linear with respect to the etching time. This results in the reduction in the etching time by a factor of 4 with an increased etching efficiency.
引用
收藏
页码:82 / 89
页数:8
相关论文
共 50 条
  • [1] Calibration of CR-39 solid state nuclear track detector
    P. Wanabongse
    B. Sola
    J. Jamsangtong
    S. Rattanabussayaporn
    Indian Journal of Physics, 2009, 83 : 833 - 837
  • [2] Calibration of solid state nuclear track detector CR-39
    Ren, GX
    Jing, GR
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (06): : 596 - 598
  • [3] Calibration of CR-39 solid state nuclear track detector
    Wanabongse, P.
    Sola, B.
    Jamsangtong, J.
    Rattanabussayaporn, S.
    INDIAN JOURNAL OF PHYSICS, 2009, 83 (06) : 833 - 837
  • [4] Optical density of the etched α-tracks in CR-39 nuclear track detector
    El Hofy, M
    Elsamman, H
    RADIATION MEASUREMENTS, 1998, 29 (05) : 461 - 464
  • [5] Calibration of solid state nuclear track detector CR-39 with monoenergetic protons
    Duan Xiao-Jiao
    Tan Zhi-Xin
    Lan Xiao-Fei
    Huang Yong-Sheng
    Guo Shi-Lun
    Yang Da-Wei
    Tang Xiu-Zhang
    Wang Nai-Yan
    ACTA PHYSICA SINICA, 2010, 59 (05) : 3147 - 3153
  • [6] Use of CR-39 solid state nuclear track detector in neutron personnel monitoring
    Dhairyawan, MP
    Marathe, PK
    Massand, OP
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 435 - 438
  • [7] THE LOW VELOCITY RESPONSE OF THE SOLID-STATE NUCLEAR TRACK DETECTOR CR-39
    SNOWDENIFFT, DP
    PRICE, PB
    PHYSICS LETTERS B, 1992, 288 (3-4) : 250 - 253
  • [8] Online optical monitor of alpha radiations using a polymeric solid state nuclear track detector CR-39
    Kulkarni, Atul
    Vyas, Chirag K.
    Kim, Hojoong
    Kalsi, Puran C.
    Kim, Taesung
    Manchanda, Vijay
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 697 - 701
  • [9] ALPHA-PARTICLE RADIOGRAPHY WITH THE CR-39 NUCLEAR TRACK DETECTOR
    DESOUZA, BA
    CABRAL, SC
    LOPES, RT
    RADIATION MEASUREMENTS, 1995, 24 (02) : 187 - 192
  • [10] Annealing of fission fragment tracks in CR-39 nuclear track detector - Phenomenological model
    Rana, Mukhtar Ahmed
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 940 : 40 - 44