Respiration Effect on Wavelet-Based ECG T-Wave End Delineation Strategies

被引:13
|
作者
Noriega, Maikel [1 ,2 ,3 ]
Pablo Martinez, Juan [1 ,5 ]
Laguna, Pablo [1 ,5 ]
Bailon, Raquel [1 ,5 ]
Almeida, Rute [1 ,4 ,5 ]
机构
[1] Ctr Invest Biomed Red Bioingn Biomat & Nanomed, Zaragoza 5000150018, Spain
[2] Oriente Univ, Commun & Elect Dept, Santiago De Cuba 90400, Cuba
[3] Univ Zaragoza, Commun Technol Grp, Aragon Inst Engn Res, IIS Aragon, Zaragoza 5000150018, Spain
[4] CMUP, P-4169007 Oporto, Portugal
[5] UZ, Commun Technol Grp, I3A, IIS Aragon, Zaragoza 5000150018, Spain
关键词
Electrocardiogram delineation; respiration; T-wave; VECTORCARDIOGRAPHIC LOOP ALIGNMENT; QT VARIABILITY; REPOLARIZATION; SIGNALS;
D O I
10.1109/TBME.2011.2157824
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The main purpose of this paper is to study the influence of the mechanical effect of respiration over the T-wave end delineation. We compared the performance of an automatic delineation system based on the wavelet transform (WT), considering single lead (SL), global delineation locations obtained from SL annotations (SLR), and multilead (ML) approaches. The linear relation between the variations on T-wave end locations obtained with each of the methods and the mechanical effect of respiration was quantified using spectral coherence and ARARX modeling both in simulated signals and in real data. We also explored the evolution of the vectorcardiographic spatial loop using the projection on the main direction of the WT in the region close to the T-wave end (T-e) and its relation with respiration. The dispersion of the additional T-wave end location error due to respiration was reduced by 15% using SLR with respect to SL, while ML allows for a reduction of around 40%. The percentage of that error correlated with respiration was in average 99% using SL while 82% and 72% using SLR and ML, respectively. Thus, results suggest that ML is the most adequate strategy for T-wave delineation, allowing the reduction of the instability of T-wave end location caused by respiration.
引用
收藏
页码:1818 / 1828
页数:11
相关论文
共 50 条
  • [31] ANTERIOR T-WAVE CHANGES IN ECG OF AN ATHLETE
    HALL, RJC
    GIBSON, RV
    BRITISH MEDICAL JOURNAL, 1978, 2 (6139): : 738 - 738
  • [32] THE SIGNIFICANCE OF THE T-WAVE INVERSION IN THE ATHLETES ECG
    SEMENITZ, B
    HORTNAGL, H
    PFISTER, R
    BAUMGARTNER, H
    RAAS, E
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1988, 9 (05) : 377 - 377
  • [33] Ambulatory measurement of the ECG T-wave amplitude
    van Lien, Rene
    Neijts, Melanie
    Willemsen, Gonneke
    de Geus, Eco J. C.
    PSYCHOPHYSIOLOGY, 2015, 52 (02) : 225 - 237
  • [34] P- and T-wave delineation in ECG signals using parametric mixture Gaussian and dynamic programming
    Rao, Achuth M., V
    Gupta, Prakhar
    Ghosh, Prasanta Kumar
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2019, 51 : 328 - 337
  • [35] T-wave vector alternans detection based on Holter ECG recordings
    Satoh, T.
    Yana, K.
    Shichiku, H.
    Mizuta, H.
    Ono, T.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2583 - 2586
  • [36] Wavelet-based hybrid ECG compression technique
    Wang Xingyuan
    Meng Juan
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2009, 59 (03) : 301 - 308
  • [37] ECG coding by wavelet-based linear prediction
    Ramakrishnan, AG
    Saha, S
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (12) : 1253 - 1261
  • [38] Wavelet-based hybrid ECG compression technique
    Wang Xingyuan
    Meng Juan
    Analog Integrated Circuits and Signal Processing, 2009, 59 : 301 - 308
  • [39] A new modified wavelet-based ECG denoising
    Wang, Zhaoyang
    Zhu, Junjiang
    Yan, Tianhong
    Yang, Lulu
    COMPUTER ASSISTED SURGERY, 2019, 24 : 174 - 183
  • [40] Wavelet-Based Variational Bayesian ECG Denoising
    Naraghi, Fateme
    Amindavar, Hamidreza
    2017 3RD INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION AND IMAGE ANALYSIS (IPRIA), 2017, : 7 - 12