Adult female voxel models of different stature and photon conversion coefficients for radiation protection

被引:73
|
作者
Fill, UA
Zankl, M
Petoussi-Henss, N [1 ]
Siebert, M
Regulla, D
机构
[1] GSF, Natl Res Ctr Environm & Hlth, Inst Radiat Protect, D-85764 Neuherberg, Germany
[2] GSF, Natl Res Ctr Environm & Hlth, Inst Med Informat, D-85764 Neuherberg, Germany
来源
HEALTH PHYSICS | 2004年 / 86卷 / 03期
关键词
dosimetry; Monte Carlo; photons; phantom;
D O I
10.1097/00004032-200403000-00003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper describes the construction of three adult female voxel models, two whole-body and one from head to thighs, from computed tomographic data of 3 women of different stature. Voxel models (also called phantoms) are human models based on computed tomographic or magnetic resonance images obtained from high resolution continuous scans of a single individual. The gray-scale data or information content of the medical images are interpreted into tissues (i.e., organs), a process known as segmentation. The phantoms, consisting of millions of volume elements, called voxels, provide a three-dimensional representation of the human body and the spatial form of its constituent organs and structures. They were initially developed for radiation protection purposes to estimate the organ and effective doses and hence the risk to a person or population due to an irradiation. This paper also presents conversion coefficients for idealized geometries of external photon exposures of energies 10 keV-1 MeV for the three female models, calculated with a Monte Carlo code. Until now there were not any published data on conversion coefficients for explicit female voxel models. Such sets of conversion coefficients exist for voxel adult males or for MIRD-type male, female, and hermaphrodite models. Numerical differences of the calculated conversion coefficients for the voxel female models and MIRD-type models can amount up to 60% or more for external exposures and are due to the improved anatomical realism of the voxel models. The size of the model also has an effect on the conversion coefficients, particularly for deeper lying organs and energies below 200 keV. The three separate sets of conversion coefficients allow one to choose the most suitable model according to the size of the individual as well as to study the dosimetric variations due to the size of the model.
引用
收藏
页码:253 / 272
页数:20
相关论文
共 46 条
  • [41] Extended conversion coefficients for use in radiation protection of the embryo and fetus against external neutrons from 10 MeV to 100 GeV
    Chen, J
    HEALTH PHYSICS, 2006, 90 (03): : 223 - 231
  • [42] Comparison of conversion coefficients for equivalent dose in terms of air kerma for photons using a male adult voxel simulator in sitting and standing posture with geometry of irradiation antero-posterior
    Galeano, D. C.
    Cavalcante, F. R.
    Carvalho Junior, A. B.
    Hunt, J.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 233 - 235
  • [43] DETERMINATION OF CALIBRATION X-RAY BEAM QUALITIES AND ESTABLISH A SET OF CONVERSION COEFFICIENTS FOR CALIBRATION OF RADIATION PROTECTION DEVICES USED IN DIAGNOSTIC RADIOLOGY
    Siddiqua, Tanjim
    Rahman, Md Shakilur
    Sanaullah, Md
    Mitu, Zohora Akter
    Hossain, Imran
    Rubai, Sadeka Sultana
    EAST EUROPEAN JOURNAL OF PHYSICS, 2021, (03): : 55 - 61
  • [44] Medical Internal Radiation Dose to Chinese Reference Adult Female Voxel Phantom Taking F18, C-11, Ga-68 Radionuclides
    Yang, K.
    Lee, C.
    Tung, C.
    Chao, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E422 - E422
  • [45] Fluence-to-absorbed-dose conversion coefficients for neutron beams from 0.001 eV to 100 GeV calculated for a set of pregnant female and fetus models
    Taranenko, Valery
    Xu, X. George
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (05): : 1425 - 1446
  • [46] IMPACT ON 141Ce, 144Ce, 95Zr, AND 90Sr BETA EMITTER DOSE COEFFICIENTS OF PHOTON AND ELECTRON SAFS CALCULATED WITH ICRP/ICRU REFERENCE ADULT VOXEL COMPUTATIONAL PHANTOMS
    Li, W. B.
    Zankl, M.
    Schlattl, H.
    Petoussi-Henss, N.
    Eckerman, K. F.
    Bolch, W. E.
    Oeh, U.
    Hoeschen, C.
    HEALTH PHYSICS, 2010, 99 (04): : 503 - 510