Sensitivity map computation in adaptive electrical capacitance volume tomography with multielectrode excitations

被引:28
|
作者
Zeeshan, Z. [1 ]
Teixeira, F. L. [1 ]
Marashdeh, Q. [2 ]
机构
[1] Ohio State Univ, Columbus, OH 43210 USA
[2] Tech4Imaging LLC, Columbus, OH USA
关键词
D O I
10.1049/el.2014.3855
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical capacitance tomography (ECT) is a low-cost, high-speed imaging technique useful in many industrial settings. ECT is predicated on the knowledge of sensitivity maps between capacitance electrodes that blanket the imaging domain. The simultaneous activation of multiple electrodes can be advantageous to manipulate the resulting field distributions and capture additional spatial information for imaging purposes. However, conventional methods for sensitivity map computation in ECT are not adequate in the presence of multielectrode activation because the mutual coupling between electrodes is not properly accounted for. This coupling becomes especially critical in adaptive electrical capacitance volume tomography (AECVT) sensors, where signals from many small electrode segments are combined into synthetic electrodes. A more general approach is presented for sensitivity map computation in AECVT based on the actual posteriori (induced) charge distributions rather than the conventional approach based on boundary conditions with no account for electrode interactions.
引用
收藏
页码:334 / 335
页数:2
相关论文
共 50 条
  • [21] Cross-Plane Acquisitions in Electrical Capacitance Volume Tomography
    Rasel, Rafiul K.
    Sines, Joshua N.
    Marashdeh, Qussai
    Teixeira, Fernando L.
    IEEE SENSORS JOURNAL, 2019, 19 (19) : 8767 - 8774
  • [23] The Sensitivity Optimization Guided Imaging Method for Electrical Capacitance Tomography
    Zhao, Qing
    Li, Jie
    Liu, Shi
    Liu, Guoqiang
    Liu, Jing
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70 (70)
  • [24] An Adaptive Total Variation Regularization Method for Electrical Capacitance Tomography
    Fan, Zhaoyan
    Gao, Robert X.
    2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 2230 - 2235
  • [25] Fast Algorithm for Image Reconstruction in Adaptive Electrical Capacitance Tomography
    Zeeshan, Z.
    Teixeira, F. L.
    Marashdeh, Q. M.
    2016 IEEE SENSORS, 2016,
  • [26] Using a fuzzy adaptive BP algorithm in electrical capacitance tomography
    Su, Xiang-fang
    Hu, Jun
    Jiang, Cao
    Wang, Yan-ping
    Wuhan Daxue Xuebao/Journal of Wuhan University, 2000, 46 (01): : 113 - 115
  • [27] Analysis of capacitance sensitivity distributions and optimal design of sensor for electrical capacitance tomography system
    Chen, DY
    Zheng, GB
    Yang, CJ
    Yu, XY
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 3, 2002, : 536 - 540
  • [29] Electrical capacitance volume tomography for imaging of pulsating flows in a trickle bed
    Wang, Aining
    Marashdeh, Qussai
    Motil, Brian J.
    Fan, Liang-Shih
    Chemical Engineering Science, 2014, 119 : 77 - 87
  • [30] Electrical Capacitance Volume Tomography for Human Brain Motion Activity Observation
    Taruno, Warsito P.
    Ihsan, Muhammad F.
    Baidillah, Marlin I.
    Tandian, Timothy
    Mahendra, Mahdi
    Aljohani, Mohammed
    2014 MIDDLE EAST CONFERENCE ON BIOMEDICAL ENGINEERING (MECBME), 2014, : 147 - 150