Determination of serum uric acid using high-performance liquid chromatography (HPLC)/isotope dilution mass spectrometry (ID-MS) as a candidate reference method

被引:173
|
作者
Dai, Xinhua [1 ]
Fang, Xiang [1 ]
Zhang, Chunmei [1 ]
Xu, Ruifeng [1 ]
Xu, Bei [1 ]
机构
[1] Natl Inst Metrol, Natl Res Ctr CRMs, Beijing 100013, Peoples R China
关键词
uric acid; serum; LC/ID-MS; candidate reference method;
D O I
10.1016/j.jchromb.2007.07.035
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Uric acid is an important diagnostic marker of catabolism of the purine nucleosides, and accurate measurements of serum uric acid are necessary for proper diagnosis of gout or renal disease appearance. A candidate reference method involving isotope dilution coupled with liquid chromatography/mass spectrometry (LC/MS) has been described. An isotopically labeled internal standard, [1,3-N-15(2)] uric acid, was added to serum, followed by equilibration and protein removal clean up to prepare samples for liquid chromatography/mass spectrometry electrospray ionization (LC/MS-ESI) analyses. (M-H)(-) ions at m/z 167 and 169 for uric acid and its labeled internal standard were monitored for LC/MS. The accuracy of the measurement was evaluated by a comparison of results of this candidate reference method on lyophilized human serum reference materials for uric acid (Standard Reference Materials SRM909b) with the certified values determined by gas chromatography/mass spectrometry reference methods and by a recovery study for the added uric acid. The method performed well against the established reference method of ion-exchange followed by derivatization isotope dilution (ID) gas chromatography mass spectrometry (ID-GC/MS). The results of this method for uric acid agreed well with the certified values and were within 0.10%. The amounts of uric acid recovered and added were in good agreement for the three concentrations. This method was applied to determine uric acid in samples of frozen serum pools. Excellent precision was obtained with within-set CVs of 0.08-0.18% and between-set CVs of 0.02-0.07% for LC/MS analyses. Liquid chromatography/tandem mass spectrometry electrospray ionization (LC/MS/MS-ESI) analysis was also performed. The LC/MS and LC/MS/MS results were in very good agreement (within 0.14%). This LC/MS method, which demonstrates good accuracy and precision, and is in the speed of analysis without the need for a derivatization stage, qualifies as a candidate reference method. This method can be used as an alternative reference method to provide an accuracy base to which the routine methods can be compared. (c) 2007 Elsevier B.V. All fights reserved.
引用
收藏
页码:287 / 295
页数:9
相关论文
共 50 条
  • [41] Measurement of serum progesterone by isotope dilution liquid chromatography tandem mass spectrometry: a candidate reference method and its application to evaluating immunoassays
    Wang, Yufei
    Zhang, Tianjiao
    Zhao, Haijian
    Zhou, Weiyan
    Zeng, Jie
    Zhang, Jiangtao
    Zhang, Chuanbao
    Chen, Wenxiang
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (11) : 2363 - 2371
  • [42] Development of isotope dilution-liquid chromatography/tandem mass spectrometry as a candidate reference method for the accurate determination of patulin in apple products
    Gab-Allah, Mohamed A.
    Choi, Kihwan
    Kim, Byungjoo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (05) : 1867 - 1879
  • [43] Determination of iohexol clearance by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS)
    Lee, Soo-Youn
    Chun, Mi-Ryung
    Kim, Dae-Joong
    Kim, Jong Won
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 839 (1-2): : 124 - 129
  • [44] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of gabapentin in human serum and plasma
    Salzmann, Linda
    Wild, Janik
    Singh, Neeraj
    Schierscher, Tobias
    Liesch, Franziska
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1955 - 1966
  • [45] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of primidone in human serum and plasma
    Schierscher, Tobias
    Salzmann, Linda
    Singh, Neeraj
    Fischer, Vanessa
    Kobel, Anja
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (07) : 1327 - 1338
  • [46] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of aldosterone in human serum and plasma
    Taibon, Judith
    Santner, Tobias
    Singh, Neeraj
    Ibrahim, Sara Cheikh
    Babitzki, Galina
    Koeppl, Daniel
    Gaudl, Alexander
    Geistanger, Andrea
    Ceglarek, Uta
    Rauh, Manfred
    Geletneky, Christian
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1902 - 1916
  • [47] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of methotrexate in human serum and plasma
    Engel, Anett
    Ruhe, Lena
    Singh, Neeraj
    Wright, Jo Anne
    Liesch, Franziska
    Bauland, Friederike
    Ostermann, Annika I. I.
    Sumalowitsch, Tamara
    Schweinsberg, Vincent J. T.
    Geistanger, Andrea
    Hegel, Johannes Kolja
    Geletneky, Christian
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1917 - 1929
  • [48] Determination of 20-hydroxyeicosatetraenoic acid in microsomal incubates using high-performance liquid chromatography-mass spectrometry (HPLC-MS)
    Bolcato, CA
    Frye, RF
    Zemaitis, MA
    Poloyac, SM
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 794 (02): : 363 - 372
  • [49] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of lamotrigine in human serum and plasma
    Salzmann, Linda
    Spescha, Tino
    Singh, Neeraj
    Schierscher, Tobias
    Bachmann, Martina
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (11) : 1930 - 1941
  • [50] An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of phenobarbital in human serum and plasma
    Schierscher, Tobias
    Salzmann, Linda
    Singh, Neeraj
    Bachmann, Martina
    Kobel, Anja
    Wild, Janik
    Bauland, Friederike
    Geistanger, Andrea
    Risch, Lorenz
    Geletneky, Christian
    Seger, Christoph
    Taibon, Judith
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (07) : 1314 - 1326