CT-based Patient-specific Simulation Software for Pedicle Screw Insertion

被引:33
|
作者
Klein, Shawn [1 ]
Whyne, Cari M. [1 ,2 ,3 ]
Rush, Raphael [1 ]
Ginsberg, Howard J. [3 ,4 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Orthopaed Biomech Lab, Sunnybrook Res Inst, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Fac Med, Dept Surg, Toronto, ON M5S 1A1, Canada
[3] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON, Canada
[4] Univ Toronto, St Michaels Hosp, Div Neurosurg, Toronto, ON M5B 1W8, Canada
来源
关键词
pedicle screw; software; patient specific; surgical simulation; IDIOPATHIC SCOLIOSIS; SURGICAL SIMULATION; ACCURACY;
D O I
10.1097/BSD.0b013e31819877fd
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: Development of a 3-dimensional, patient-specific simulator for pedicle screw insertion. Objective: To allow the user to practice the insertion of pedicle screws into a 3-dimensional model of a patient-specific spine, and have both visual and quantitative feedback provided to the user. The goal is to better prepare surgeons to perform pedicle screw insertion surgery and help reduce the risk of pedicle screw misplacement. Summary of Background Data: Pedicle screw insertion is particularly challenging to carry out on patients with abnormal spine morphology. Currently, preoperative planning for pedicle screw insertion is carried out using patient computed tomography and magnetic resonance imaging scans. In addition, once screws are inserted, there are no quantitative metrics against which to measure the results. Methods: The simulator was developed in the TCL scripting language as a graphical plug-in for the commercial visualization software AmiraDev 3.11. Surgical simulation uses a 3-dimensional model of patient's spine developed from the patient's computed tomography scan. Results: Pedicle screw insertion can be practiced using pedicle screws of various sizes and analyzed in both 2-dimension and 3-dimension. Quantitative feedback is provided to the user in the form of anatomic lengths and angles, relative purchase of inserted screws, and a screw placement grading system. The software allows the user to adjust the translucency of a patient's spine to develop a better sense of the trajectories and depths involved with performing pedicle screw insertion on a patient. Conclusions: The simulator offers many helpful features to the surgeon with respect to complex cases and to the surgical trainee learning the basic technique of pedicle screw insertion. A study is currently underway to evaluate the efficacy of the simulator as a teaching tool for surgical trainees in placing pedicle screws. Future work will focus on the transfer of the software to a stand-alone platform.
引用
收藏
页码:502 / 506
页数:5
相关论文
共 50 条
  • [31] Effect of pedicle screw angles on the fracture risk of the human vertebra: A patient-specific computational model
    Molinari, Leonardo
    Falcinelli, Cristina
    Gizzi, Alessio
    Martino, Alberto Di
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 116
  • [32] Are computer numerical control (CNC)-manufactured patient-specific metal templates available for posterior thoracic pedicle screw insertion? Feasibility and accuracy evaluation
    Xiangxue Kong
    Lei Tang
    Qiang Ye
    Wenhua Huang
    Jianyi Li
    European Spine Journal, 2017, 26 : 2927 - 2933
  • [33] Are computer numerical control (CNC)-manufactured patient-specific metal templates available for posterior thoracic pedicle screw insertion? Feasibility and accuracy evaluation
    Kong, Xiangxue
    Tang, Lei
    Ye, Qiang
    Huang, Wenhua
    Li, Jianyi
    EUROPEAN SPINE JOURNAL, 2017, 26 (11) : 2927 - 2933
  • [34] Accuracy of patient-specific CT organ doses from Monte Carlo simulations: influence of CT-based voxel models
    Verfaillie, Gwenny
    Rutten, Jeff
    DAsseler, Yves
    Bacher, Klaus
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (03) : 989 - 1000
  • [35] Corrective osteotomies of phalangeal and metacarpal malunions using patient-specific guides: CT-based accuracy evaluation
    Hirsiger, Stefanie
    Miyake, Junichi
    Furnstahl, Philipp
    Nagy, Ladislav
    Schweizer, Andreas
    SWISS MEDICAL WEEKLY, 2015, 145 : 21S - 21S
  • [36] Dual-energy CT-based proton treatment planning to assess patient-specific range uncertainties
    Wohlfahrt, P.
    Moehler, C.
    Enghardt, W.
    Greilich, S.
    Richter, C.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S73 - S75
  • [37] Fracture risk assessment in metastatic femurs: a patient-specific CT-based finite-element approach
    Cristina Falcinelli
    Alberto Di Martino
    Alessio Gizzi
    Giuseppe Vairo
    Vincenzo Denaro
    Meccanica, 2020, 55 : 861 - 881
  • [38] Fracture risk assessment in metastatic femurs: a patient-specific CT-based finite-element approach
    Falcinelli, Cristina
    Di Martino, Alberto
    Gizzi, Alessio
    Vairo, Giuseppe
    Denaro, Vincenzo
    MECCANICA, 2020, 55 (04) : 861 - 881
  • [39] A novel Patient-Specific Three-Dimensional Printing Template Based on External Fixation for Pelvic Screw Insertion
    Zhou, Kaihua
    Tao, Xingguang
    Pan, Fugen
    Luo, Congfeng
    Yang, Huilin
    JOURNAL OF INVESTIGATIVE SURGERY, 2022, 35 (02) : 459 - 466
  • [40] Pedicle Screw Safety: How Much Anterior Breach Is Safe? A Cadaveric and CT-Based Study
    Sarwahi, Vishal
    Payares, Monica
    Wendolowski, Stephen
    Gecelter, Rachel
    Maguire, Kathleen
    Wang, Dan
    Thornhill, Beverly
    Amaral, Terry
    SPINE, 2017, 42 (22) : E1305 - E1310