CT-based Patient-specific Simulation Software for Pedicle Screw Insertion

被引:33
|
作者
Klein, Shawn [1 ]
Whyne, Cari M. [1 ,2 ,3 ]
Rush, Raphael [1 ]
Ginsberg, Howard J. [3 ,4 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Orthopaed Biomech Lab, Sunnybrook Res Inst, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Fac Med, Dept Surg, Toronto, ON M5S 1A1, Canada
[3] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON, Canada
[4] Univ Toronto, St Michaels Hosp, Div Neurosurg, Toronto, ON M5B 1W8, Canada
来源
关键词
pedicle screw; software; patient specific; surgical simulation; IDIOPATHIC SCOLIOSIS; SURGICAL SIMULATION; ACCURACY;
D O I
10.1097/BSD.0b013e31819877fd
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: Development of a 3-dimensional, patient-specific simulator for pedicle screw insertion. Objective: To allow the user to practice the insertion of pedicle screws into a 3-dimensional model of a patient-specific spine, and have both visual and quantitative feedback provided to the user. The goal is to better prepare surgeons to perform pedicle screw insertion surgery and help reduce the risk of pedicle screw misplacement. Summary of Background Data: Pedicle screw insertion is particularly challenging to carry out on patients with abnormal spine morphology. Currently, preoperative planning for pedicle screw insertion is carried out using patient computed tomography and magnetic resonance imaging scans. In addition, once screws are inserted, there are no quantitative metrics against which to measure the results. Methods: The simulator was developed in the TCL scripting language as a graphical plug-in for the commercial visualization software AmiraDev 3.11. Surgical simulation uses a 3-dimensional model of patient's spine developed from the patient's computed tomography scan. Results: Pedicle screw insertion can be practiced using pedicle screws of various sizes and analyzed in both 2-dimension and 3-dimension. Quantitative feedback is provided to the user in the form of anatomic lengths and angles, relative purchase of inserted screws, and a screw placement grading system. The software allows the user to adjust the translucency of a patient's spine to develop a better sense of the trajectories and depths involved with performing pedicle screw insertion on a patient. Conclusions: The simulator offers many helpful features to the surgeon with respect to complex cases and to the surgical trainee learning the basic technique of pedicle screw insertion. A study is currently underway to evaluate the efficacy of the simulator as a teaching tool for surgical trainees in placing pedicle screws. Future work will focus on the transfer of the software to a stand-alone platform.
引用
收藏
页码:502 / 506
页数:5
相关论文
共 50 条
  • [1] Safe and Accurate Midcervical Pedicle Screw Insertion Procedure With the Patient-Specific Screw Guide Template System
    Kaneyama, Shuichi
    Sugawara, Taku
    Sumi, Masatoshi
    SPINE, 2015, 40 (06) : E341 - E348
  • [2] Impact of osteosclerosis on cervical pedicle screw insertion using preoperative CT-based navigation
    Uehara, Masashi
    Ikegami, Shota
    Oba, Hiroki
    Miyaoka, Yoshinari
    Hatakenaka, Terue
    Kurogochi, Daisuke
    Fukuzawa, Takuma
    Sasao, Shinji
    Mimura, Tetsuhiko
    Takahashi, Jun
    EUROPEAN SPINE JOURNAL, 2024, 33 (06) : 2298 - 2303
  • [3] Analysis of CT-based Navigation System for Pedicle Screw Placement
    Hodges, Scott D.
    Eck, Jason C.
    Newton, Danette
    ORTHOPEDICS, 2012, 35 (08) : E1221 - E1224
  • [4] A Novel Patient-Specific Navigational Template for Cervical Pedicle Screw Placement
    Lu, Sheng
    Xu, Yong Q.
    Lu, William W.
    Ni, Guo X.
    Li, Yan B.
    Shi, Ji H.
    Li, Dong P.
    Chen, Guo P.
    Chen, Yu B.
    Zhang, Yuan Z.
    SPINE, 2009, 34 (26) : E959 - E964
  • [5] Radiographic accuracy in TKA with a CT-based patient-specific cutting block technique
    Koch, P. P.
    Mueller, D.
    Pisan, M.
    Fucentese, S. F.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) : 2200 - 2205
  • [6] A novel technique for C1-C2 posterior screw insertion using patient-specific guides created by CT-based 3D printing
    Kagami, Yujiro
    Nakashima, Hiroaki
    Segi, Naoki
    Ito, Sadayuki
    Ouchida, Jun
    Shinjo, Ryuichi
    Imagama, Shiro
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2024, 86 (03): : 487 - 496
  • [7] Radiographic accuracy in TKA with a CT-based patient-specific cutting block technique
    Koch, Peter
    Fucentese, Sandro
    Pisan, Markus
    Mueller, Daniel
    SWISS MEDICAL WEEKLY, 2014, 144 : 17S - 17S
  • [8] Radiographic accuracy in TKA with a CT-based patient-specific cutting block technique
    P. P. Koch
    D. Müller
    M. Pisan
    S. F. Fucentese
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2200 - 2205
  • [9] Outcomes following total knee arthroplasty with CT-based patient-specific instrumentation
    Zhu, Meng
    Chen, Jerry Yongqiang
    Chong, Hwei Chi
    Yew, Andy Khye Soon
    Foo, Leon Siang Shen
    Chia, Shi-Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (08) : 2567 - 2572
  • [10] CT-Based Patient-Specific Modeling of Glenoid Rim Defects: A Feasibility Study
    Diederichs, Gerd
    Seim, Heiko
    Meyer, Henning
    Issever, Ahi S.
    Link, Thomas M.
    Schroeder, Ralf J.
    Scheibel, Markus
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (05) : 1406 - 1411