TOF Data Non-Rigid Motion Correction

被引:0
|
作者
Panin, V. Y. [1 ]
机构
[1] Siemens Healthcare, Mol Imaging, Knoxville, TN 37932 USA
来源
2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2015年
关键词
RESPIRATORY MOTION; PET DATA; RECONSTRUCTION;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PET acquisition requires prolonged scan times, and during the scan a large magnitude of patient motion can occur. Breathing may result in a significant displacement of organs and consequent blurring of clinically relevant features. Various non-rigid motion corrections that act in the image space were proposed to address this problem. TOF data can be considered to be histo-images. Therefore, non-rigid motion correction can be performed in this quasi image space. The TOF locality property can be used to locally perform motion correction; that is, the approximation of motion as locally rigid on a scale of TOF resolution. In this work we investigate motion correction in the TOF data space, assuming a known motion field. Data correction factors, such as normalization and attenuation, will be combined for motion compensation depending on the combination of data. The benefit of the presented motion correction is that only one data set needs to be used for the final reconstruction. An XCAT phantom is used in computer simulations. Initial results showed that the presented methodology accommodates for changes in non-rigid body movements for a typical pattern of patient motion.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Respiratory motion correction in PET with super-resolution techniques and non-rigid registration
    Rubio-Guivernau, Jose L.
    Ledesma-Carbayo, Maria J.
    Lamare, Frederic
    Ortuno, Juan E.
    Guerra, Pedro
    Visvikis, Dimitris
    Santos, Andres
    Kontaxakis, George
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3560 - +
  • [22] Investigation of Respiratory Motion Correction with and without Motion Correction of Attenuation Map in Cardiac SPECT/CT in Presence of Non-Rigid Motion, an NCAT study
    Dey, Joyoni
    Segars, W. P.
    Pretorius, P. Hendrik
    King, Michael A.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3237 - 3243
  • [23] Evaluation of Rigid and Non-rigid Motion Compensation of Cardiac Perfusion MRI
    Xue, Hui
    Guehring, Jens
    Srinivasan, Latha
    Zuehlsdorff, Sven
    Saddi, Kinda
    Chefdhotel, Christophe
    Hajnal, Joseph V.
    Rueckert, Daniel
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT II, PROCEEDINGS, 2008, 5242 : 35 - 43
  • [24] VISUAL INFORMATION ABOUT RIGID AND NON-RIGID MOTION - A GEOMETRIC ANALYSIS
    TODD, JT
    JOURNAL OF EXPERIMENTAL PSYCHOLOGY-HUMAN PERCEPTION AND PERFORMANCE, 1982, 8 (02) : 238 - 252
  • [25] Simultaneous PET–MR acquisition and MR-derived motion fields for correction of non-rigid motion in PET
    Charalampos Tsoumpas
    Jane E. Mackewn
    Philip Halsted
    Andrew P. King
    Christian Buerger
    John J. Totman
    Tobias Schaeffter
    Paul K. Marsden
    Annals of Nuclear Medicine, 2010, 24 : 745 - 750
  • [26] Integrating temporal information with a non-rigid method of motion correction for functional magnetic resonance images
    Bannister, Peter R.
    Brady, J. Michael
    Jenkinson, Mark
    IMAGE AND VISION COMPUTING, 2007, 25 (03) : 311 - 320
  • [27] Probabilistic tracking and recognition of non-rigid hand motion
    Fei, H
    Reid, I
    IEEE INTERNATIONAL WORKSHOP ON ANALYSIS AND MODELING OF FACE AND GESTURES, 2003, : 60 - 67
  • [28] A Benchmark and Evaluation of Non-Rigid Structure from Motion
    Jensen, Sebastian Hoppe Nesgaard
    Doest, Mads Emil Brix
    Aanaes, Henrik
    Del Bue, Alessio
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 2021, 129 (04) : 882 - 899
  • [29] LANMC: LSTM-Assisted Non-Rigid Motion Correction on FPGA for Calcium Image Stabilization
    Chen, Zhe
    Blair, Hugh T.
    Cong, Jason
    PROCEEDINGS OF THE 2019 ACM/SIGDA INTERNATIONAL SYMPOSIUM ON FIELD-PROGRAMMABLE GATE ARRAYS (FPGA'19), 2019, : 104 - 109
  • [30] Feasibility of online non-rigid motion correction for high-resolution supine breast MRI
    Isaieva, Karyna
    Meullenet, Camille
    Vuissoz, Pierre-Andre
    Fauvel, Marc
    Nohava, Lena
    Laistler, Elmar
    Zeroual, Mohamed Aziz
    Henrot, Philippe
    Felblinger, Jacques
    Odille, Freddy
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (05) : 2130 - 2143