Biomechanical comparison of double-row versus transtendon single-row suture anchor technique for repair of the grade III partial articular-sided rotator cuff tears

被引:1
|
作者
Zhang Chun-gang [1 ]
Zhao De-wei [1 ]
Wang Wei-ming [1 ]
Ren Ming-fa [2 ]
Li Rui-xin [1 ]
Yang Sheng [1 ]
Liu Yu-peng [1 ]
机构
[1] Dalian Univ Technol, Affiliated Zhongshan Hosp, Dept Orthoped, Dalian 116001, Liaoning, Peoples R China
[2] Dalian Univ Technol, State Key Lab Struct Anal Ind Equipment, Dalian 116001, Liaoning, Peoples R China
关键词
biomechanics; rotator cuff; suture anchor; INFERIOR GLENOHUMERAL LIGAMENT; SUPRASPINATUS TENDON TEARS; PARTIAL-THICKNESS TEARS; ARTHROSCOPIC REPAIR; ANTERIOR BAND; IN-VITRO; ARTHROGRAPHY; FIXATION; STRENGTH; POSITION;
D O I
10.3760/cmaj.issn.0366-6999.2010.21.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background For partial-thickness tears of the rotator cuff, double-row fixation and transtendon single-row fixation restore insertion site anatomy, with excellent results. We compared the biomechanical properties of double-row and transtendon single-row suture anchor techniques for repair of grade III partial articular-sided rotator cuff tears. Methods In 10 matched pairs of fresh-frozen sheep shoulders, the infraspinatus tendon from 1 shoulder was repaired with a double-row suture anchor technique. This comprised placement of 2 medial anchors with horizontal mattress sutures at an angle of <= 45 degrees into the medial margin of the infraspinatus footprint, just lateral to the articular surface, and 2 lateral anchors with horizontal mattress sutures. Standardized, 50% partial, articular-sided infraspinatus lesions were created in the contralateral shoulder. The infraspinatus tendon from the contralateral shoulder was repaired using two anchors with transtendon single-row mattress sutures. Each specimen underwent cyclic loading from 10 to 100 N for 50 cycles, followed by tensile testing to failure. Gap formation and strain over the footprint area were measured using a motion capture system; stiffness and failure load were determined from testing data. Results Gap formation for the transtendon single-row repair was significantly smaller (P <0.05) when compared with the double-row repair for the first cycle ((1.74+/-0.38) mm vs. (2.86+/-0.46) mm, respectively) and the last cycle ((3.77+/-0.45) mm vs. (5.89+/-0.61) mm, respectively). The strain over the footprint area for the transtendon single-row repair was significantly smaller (P <0.05) when compared with the double-row repair. Also, it had a higher mean ultimate tensile load and stiffness. Conclusions For grade III partial articular-sided rotator cuff tears, transtendon single-row fixation exhibited superior biomechanical properties when compared with double-row fixation. Chin Med J 2010;123(21):3049-3054
引用
收藏
页码:3049 / 3054
页数:6
相关论文
共 50 条
  • [31] Single-row versus double-row arthroscopic rotator cuff repair in small- to medium-sized tears
    Aydin, Nuri
    Kocaoglu, Baris
    Guven, Osman
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (05) : 722 - 725
  • [32] Single-row versus double-row arthroscopic repair in the treatment of rotator cuff tears: a prospective randomized clinical study
    Carbonel, Ignacio
    Antonio Martinez, Angel
    Calvo, Angel
    Ripalda, Jorge
    Herrera, Antonio
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (09) : 1877 - 1883
  • [33] Single-row versus double-row arthroscopic repair in the treatment of rotator cuff tears: a prospective randomized clinical study
    Ignacio Carbonel
    Angel Antonio Martinez
    Angel Calvo
    Jorge Ripalda
    Antonio Herrera
    International Orthopaedics, 2012, 36 : 1877 - 1883
  • [34] Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material
    M. H. Baums
    G. H. Buchhorn
    G. Spahn
    B. Poppendieck
    W. Schultz
    H.-M. Klinger
    Knee Surgery, Sports Traumatology, Arthroscopy, 2008, 16 : 1052 - 1060
  • [35] Biomechanical characteristics of single-row repair in comparison to double-row repair with consideration of the suture configuration and suture material
    Baums, M. H.
    Buchhorn, G. H.
    Spahn, G.
    Poppendieck, B.
    Schultz, W.
    Klinger, H. -M.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (11) : 1052 - 1060
  • [36] SCOI Row Technique Versus Double-Row Suture Bridge Technique for Repairing Rotator Cuff Tears: A Biomechanical and Histological Study in Rabbits
    Lu, Han-Yu
    Yang, Yi-Xin
    Li, Wen-Jun
    Du, Min
    Lin, Shi-Long
    Sun, Qi-Jie
    Liu, Yue-Lin
    Gao, Mu
    Zheng, Xiao-Fei
    He, He-Bei
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2025,
  • [37] Biomechanical comparison of single-row arthroscopic rotator cuff repair technique versus transosseous repair technique
    Tocci, Stephen L.
    Tashjian, Robert Z.
    Leventhal, Evan
    Spenciner, David B.
    Green, Andrew
    Fleming, Braden C.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2008, 17 (05) : 808 - 814
  • [38] Single-row modified Mason-Allen versus double-row arthroscopic rotator cuff repair: A biomechanical and surface area comparison
    Nelson, Cory O.
    Sileo, Michael J.
    Grossman, Mark G.
    Serra-Hsu, Frederick
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2008, 24 (08): : 941 - 948
  • [39] Double-Row Repair Technique for Bursal-Sided Partial-Thickness Rotator Cuff Tears
    Salem, Hytham
    Carter, Aaron
    Tjoumakaris, Fotios
    Freedman, Kevin B.
    ARTHROSCOPY TECHNIQUES, 2018, 7 (03): : E199 - E203
  • [40] Clinical Outcomes of Double-Row Versus Single-Row Rotator Cuff Repairs
    Wall, Lindley B.
    Keener, Jay D.
    Brophy, Robert H.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2009, 25 (11): : 1312 - 1318