Optimizing separation conditions for proteins and peptides using imaged capillary isoelectric focusing

被引:59
|
作者
Wu, JQ [1 ]
Li, SC [1 ]
Watson, A [1 ]
机构
[1] Convergent Biosci Ltd, Toronto, ON M8Z 2L8, Canada
关键词
capillary isoelectric focusing; detection; electrophoresis; whole-column imaging detection; proteins; antibodies; peptides; glycoproteins;
D O I
10.1016/S0021-9673(98)00326-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Separation conditions for antibodies, glycoproteins and peptides were optimized to fully realize the potential of automated imaged capillary isoelectric focusing (imaged cIEF) for protein analysis. Two commercially available capillary coatings, polyacrylamide and fluorocarbon, were found to provide reproducible results for cIEF separations. Both coatings could last more than 100 runs under normal cIEF conditions. Up to 30 mM salts (Na+) could be added to samples to prevent protein precipitation before and during isoelectric focusing performed under imaged cIEF. Short analysis time of the imaged cIEF also aided in the prevention of protein precipitation. High current at the beginning of the focusing for samples in salt could be avoided by applying a voltage gradient. Additions of up to 6 M urea and 20% glycerol could enhance solubility of proteins and peptide. Imaged cIEF was applied to the quantitation of monoclonal antibodies. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:163 / 171
页数:9
相关论文
共 50 条
  • [31] NEW APPROACHES TO CAPILLARY ISOELECTRIC-FOCUSING OF PROTEINS
    SCHWARTZ, H
    PRITCHETT, T
    BIO-TECHNOLOGY, 1994, 12 (04): : 408 - 409
  • [32] Isoelectric focusing sample injection for capillary electrophoresis of proteins
    Wu, XZ
    Zhang, LH
    Onoda, K
    ELECTROPHORESIS, 2005, 26 (03) : 563 - 570
  • [33] Isoelectric focusing of proteins and peptides in gel slabs and in capillaries
    Righetti, PG
    Bossi, A
    ANALYTICA CHIMICA ACTA, 1998, 372 (1-2) : 1 - 19
  • [34] Rapid modification of capillaries by chicken egg white and their uses for separation of proteins in capillary isoelectric focusing
    Yang, C
    Zhang, WB
    Zhang, YK
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (09) : 1097 - 1100
  • [35] A stable and high-resolution isoelectric focusing capillary array device for micropreparative separation of proteins
    Li, Si
    Dong, Jing-Yu
    Guo, Chen-Gang
    Wu, Yi-Xin
    Zhang, Wei
    Fan, Liu-yin
    Cao, Cheng-Xi
    Zhang, Wei-Bing
    TALANTA, 2013, 116 : 259 - 265
  • [36] Isoelectric point analysis of proteins and peptides by capillary isoelectric focusing with two-wavelength laser-induced fluorescence detection
    Verbeck, IV, Guido F.
    Beale, Stephen C.
    Journal of Microcolumn Separations, 11 (10): : 708 - 715
  • [37] Isoelectric point analysis of proteins and peptides by capillary isoelectric focusing with two-wavelength laser-induced fluorescence detection
    Verbeck, GF
    Beale, SC
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1999, 11 (10) : 708 - 715
  • [38] Imaged capillary isoelectric focusing method development for charge variants of high DAR ADCs
    Leng, Chuan
    Sun, Shuwen
    Lin, Wei
    Pavon, Jorge Alexander
    Gennaro, Lynn
    Gunawan, Rico C.
    Bu, Xiaodong
    Yang, Tong
    Li, Senwu
    ANALYTICA CHIMICA ACTA, 2024, 1328
  • [39] Capillary electrophoresis of peptides and proteins in isoelectric buffers: An update
    Righetti, PG
    Gelfi, C
    Bossi, A
    Olivieri, E
    Castelletti, L
    Verzola, B
    Stoyanov, AV
    ELECTROPHORESIS, 2000, 21 (18) : 4046 - 4053
  • [40] Exploring imaged capillary isoelectric focusing parameters for enhanced charge variants quality control
    Ghizzani, Virginia
    Ascione, Alessandro
    Gonnella, Federico
    Massolini, Gabriella
    Luciani, Francesca
    FRONTIERS IN CHEMISTRY, 2025, 13