Energy and economic performance analysis of an open cycle solar desiccant dehumidification air-conditioning system for application in Hong Kong

被引:53
|
作者
Li, Yutong [1 ]
Lu, Lin [1 ]
Yang, Hongxing [1 ]
机构
[1] Hong Kong Polytech Univ, RERG, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Solar desiccant dehumidification; Energy performance; Economical analysis; VAPOR-COMPRESSION; FEASIBILITY; SIMULATION;
D O I
10.1016/j.solener.2010.09.006
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this article, a transient simulation model and the EnergyPlus were used to study the energy performance and economical feasibility for integrating a solar liquid desiccant dehumidification system with a conventional vapor compression air-conditioning system for the weather condition of Hong Kong The vapor compression system capacity in the solar assisted air-conditioning system can be reduced to 19 kW from original 28 kW of a conventional air conditioning system as a case study due to the solar desiccant cooling The economical performance of the solar desiccant dehumidification system is compared with that of the conventional air-conditioning system The results show that the energy saving potentials due to incorporation of the solar desiccant dehumidification system in a traditional air-conditioning system is significant for the hot wet weather in Hong Kong due to higher COP resulted from higher supply chilled water temperature from chiller plants The annual operation energy savings for the hybrid system is 6760 kWh and the payback period of the hybrid system is around 7 years The study shows that the solar assisted air-conditioning is a viable technology for utilizations in subtropical areas (C) 2010 Elsevier Ltd All rights reserved
引用
收藏
页码:2085 / 2095
页数:11
相关论文
共 50 条
  • [41] Energy Consumption Analysis of a Liquid Desiccant Air-conditioning System for Industrial Buildings
    Tang, Yidan
    Liu, Xiaohua
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 551 - 558
  • [42] Study on the Application of Rotary Desiccant Air-Conditioning System on Ships
    Chen, Wu
    Yang, Guanghai
    ADVANCED SCIENCE LETTERS, 2011, 4 (4-5) : 1410 - 1415
  • [43] Application of Internal Cooled Desiccant Wheel in Air-Conditioning System
    Zhou Xingchao
    Goldsworthy, Mark
    Sproul, Alistair
    2018 ASHRAE ANNUAL CONFERENCE, 2018,
  • [44] Performance analysis of a liquid desiccant and membrane contactor hybrid air-conditioning system
    Bergero, Stefano
    Chiari, Anna
    ENERGY AND BUILDINGS, 2010, 42 (11) : 1976 - 1986
  • [45] Study on Desiccant Air-Conditioning System for Livestock Application in Pakistan
    Niaz, Hassan
    Sultan, Muhammad
    Miyazaki, Takahiko
    Khan, Zahid M.
    2018 2ND INTERNATIONAL CONFERENCE ON ENERGY CONSERVATION AND EFFICIENCY (ICECE), 2018, : 19 - 22
  • [46] An experience of energy auditing on a central air-conditioning plant in Hong Kong
    Yik, FWH
    Burnett, J
    ENERGY ENGINEERING, 1995, 92 (02) : 6 - 30
  • [47] Experience of energy auditing on a central air-conditioning plant in Hong Kong
    Hong Kong Polytechnic Univ, Kowloon, Hong Kong
    Energy Eng, 2 (6-30):
  • [48] Theoretical and experimental investigation of the performance of a desiccant air-conditioning system
    Panaras, G.
    Mathioulakis, E.
    Belessiotis, V.
    Kyriakis, N.
    RENEWABLE ENERGY, 2010, 35 (07) : 1368 - 1375
  • [49] Energy and exergy performance analysis of a marine rotary desiccant air-conditioning system based on orthogonal experiment
    Zhu, Jun
    Chen, Wu
    ENERGY, 2014, 77 : 953 - 962
  • [50] Performance evaluation of silica-gel based desiccant dehumidification unit for air-conditioning applications
    Siddique, Akash
    Sultan, Muhammad
    2019 3RD INTERNATIONAL CONFERENCE ON ENERGY CONSERVATION AND EFFICIENCY (ICECE), 2019, : 50 - 54