Surface plasmon resonance biosensor using heterodyne interferometry

被引:0
|
作者
Joe, SF
Wu, CM
Chang, LB
Hsieh, LZ
机构
关键词
surface plasmon resonance; biosensor; heterodyne inteferometry;
D O I
10.1117/12.573719
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A Surface plasmon resonance (SPR) biosensor constructed with common path, heterodyne inteferometric system has been developed. The sensor ship consists of a BK7 substrate coated with gold film on which the receptor of the specific biomolecular or protein has been immobilized. The light source consisting of the s and p polarizations with heterodyne frequency of 60kHz is used to measure the phase difference between these two polarizations. Because the SPR sensor probes the changes of refractive index near the gold film (i.e. about one wave-length), the more the binding of molecules on the sensing surface results in the less sensitivity of the detection. In order to overcome this shortage, we set two quarter-wave plates before and after the SPR prism to make the sensitivity of measurement to be tunable. This sensor could detect the concentration of antibody of sheep IgG as low as several nanograms per milliliter. The results indicate that this system provides high sensitivity and is capable for detecting biomolecular interactions.
引用
收藏
页码:166 / 173
页数:8
相关论文
共 50 条
  • [31] Measurement of refractive index variation of liquids by surface plasmon resonance and wavelength-modulated heterodyne interferometry
    Lee, Ju-Yi
    Tsai, Shin-Kai
    OPTICS COMMUNICATIONS, 2011, 284 (04) : 925 - 929
  • [32] New Type Small-Angle Sensor Based on the Surface Plasmon Resonance Technology in Heterodyne Interferometry
    Wang, Shinn-Fwu
    Kao, Fu-Hsi
    Liu, An-Li
    Chiu, Jyh-Shyan
    Lai, Wesley
    Hsieh, Meng-Feng
    Chung, Hung-Chen
    2011 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2011, : 942 - 945
  • [33] Design of a small-displacement sensing system based on the surface plasmon resonance technology in heterodyne interferometry
    Wang, Shinn-Fwu
    Yang, Wayne
    Liu, An-Li
    Kao, Fu-Hsi
    Lay, Shyh-Rong
    2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 1391 - 1394
  • [34] Label-free DNA biosensor based on localized surface plasmon resonance coupled with interferometry
    Kim, Do-Kyun
    Kerman, Kagan
    Saito, Masato
    Sathuluri, Ramachandra Rao
    Endo, Tatsuro
    Yamamura, Shohei
    Kwon, Young-Soo
    Tamiya, Eiichi
    ANALYTICAL CHEMISTRY, 2007, 79 (05) : 1855 - 1864
  • [35] CHARACTERIZATION OF BIOMEMBRANES BY SPECTRAL ELLIPSOMETRY, SURFACE-PLASMON RESONANCE AND INTERFEROMETRY WITH REGARD TO BIOSENSOR APPLICATION
    STRIEBEL, C
    BRECHT, A
    GAUGLITZ, G
    BIOSENSORS & BIOELECTRONICS, 1994, 9 (02): : 139 - 146
  • [36] Polarimetric surface plasmon resonance imaging biosensor
    Duval, Aurelien
    Laisne, Aude
    Pompon, Denis
    Held, Sylvain
    Bellemain, Alain
    Moreau, Julien
    Canva, Michael
    OPTICS LETTERS, 2009, 34 (23) : 3634 - 3636
  • [37] A novel multichannel surface plasmon resonance biosensor
    Homola, J
    Lu, HBB
    Nenninger, GG
    Dostálek, J
    Yee, SS
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) : 403 - 410
  • [38] Surface plasmon resonance biosensor for microalbumin detection
    Liu, Jen-Tsai
    Lin, Po-Shen
    Hsin, Yue-Ming
    Tsai, Jang-Zern
    Chen, Wen-Yih
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2011, 42 (05) : 696 - 700
  • [39] A Novel Photonic Crystal Fiber Biosensor Using Surface Plasmon Resonance
    Rifat, A. A.
    Mahdiraji, G. Amouzad
    Shee, Y. G.
    Shawon, Md. Jubayer
    Adikan, F. R. Mahamd
    INTERNATIONAL CONFERENCE ON MATERIALS FOR ADVANCED TECHNOLOGIES (ICMAT2015) - 4TH PHOTONICS GLOBAL CONFERENCE 2015, 2016, 140 : 1 - 7
  • [40] SURFACE PLASMON RESONANCE BIOSENSOR IN HEALTHCARE APPLICATION
    Alim, Nusrat
    Uddin, Mohammad Nasir
    2017 IEEE REGION 10 INTERNATIONAL SYMPOSIUM ON TECHNOLOGIES FOR SMART CITIES (IEEE TENSYMP 2017), 2017,