A Surface plasmon resonance (SPR) biosensor constructed with common path, heterodyne inteferometric system has been developed. The sensor ship consists of a BK7 substrate coated with gold film on which the receptor of the specific biomolecular or protein has been immobilized. The light source consisting of the s and p polarizations with heterodyne frequency of 60kHz is used to measure the phase difference between these two polarizations. Because the SPR sensor probes the changes of refractive index near the gold film (i.e. about one wave-length), the more the binding of molecules on the sensing surface results in the less sensitivity of the detection. In order to overcome this shortage, we set two quarter-wave plates before and after the SPR prism to make the sensitivity of measurement to be tunable. This sensor could detect the concentration of antibody of sheep IgG as low as several nanograms per milliliter. The results indicate that this system provides high sensitivity and is capable for detecting biomolecular interactions.
引用
收藏
页码:166 / 173
页数:8
相关论文
共 50 条
  • [1] Optical heterodyne surface plasmon resonance biosensor
    Chou, C
    Kuo, WC
    Wu, HT
    OPTICAL FIBERS AND SENSORS FOR MEDICAL APPLICATIONS III, 2003, 4957 : 149 - 156
  • [2] Measurement of wavelength shift by using surface plasmon resonance heterodyne interferometry
    Chen, KH
    Hsu, CC
    Su, DC
    OPTICS COMMUNICATIONS, 2002, 209 (1-3) : 167 - 172
  • [3] Optical heterodyne surface-plasmon resonance biosensor
    Kuo, WC
    Chou, C
    Wu, HT
    OPTICS LETTERS, 2003, 28 (15) : 1329 - 1331
  • [4] D-type fiber biosensor based on surface-plasmon resonance technology and heterodyne interferometry
    Chiu, MH
    Wang, SF
    Chang, RS
    OPTICS LETTERS, 2005, 30 (03) : 233 - 235
  • [5] Measuring physical parameters with surface plasmon resonance heterodyne interferometry
    Chen, Kun-Huang
    Lin, Jiun-You
    Chen, Jing-Heng
    OPTIK, 2009, 120 (01): : 29 - 34
  • [6] Measurement of the concentration of a solution with surface plasmon resonance heterodyne interferometry
    Chen, KH
    Hsu, CC
    Su, DC
    OPTICAL ENGINEERING, 2003, 42 (07) : 1884 - 1887
  • [7] Angle measurement using surface-plasmon-resonance heterodyne interferometry: a new method
    Guo, JH
    Zhu, ZM
    Deng, WM
    Shen, S
    OPTICAL ENGINEERING, 1998, 37 (11) : 2998 - 3001
  • [8] Measurement of small displacement based on surface plasmon resonance heterodyne interferometry
    Lin, Jiun-You
    Chen, Kun-Huang
    Chen, Jing-Heng
    OPTICS AND LASERS IN ENGINEERING, 2011, 49 (07) : 811 - 815
  • [9] Surface plasmon resonance heterodyne interferometry from measuring physical parameters
    Su, DC
    Chen, JH
    Chen, KH
    Lin, JY
    OPTICAL METROLOGY IN PRODUCTION ENGINEERING, 2004, 5457 : 566 - 573
  • [10] A Biochemical Sensor Based on Surface Plasmon Resonance Technology in Heterodyne Interferometry
    Chiu, Jyh-Shyan
    Wang, Shinn-Fwu
    Wang, Wen-June
    2018 INTERNATIONAL CONFERENCE ON SYSTEM SCIENCE AND ENGINEERING (ICSSE), 2018,