Steady-state performance evaluation and energy assessment of a complete membrane-based liquid desiccant dehumidification system

被引:22
|
作者
Bai, Hongyu [1 ]
Zhu, Jie [1 ]
Chen, Xiangjie [1 ]
Chu, Junze [1 ]
Cui, Yuanlong [2 ]
Yan, Yuying [1 ]
机构
[1] Univ Nottingham, Dept Architecture & Built Environm, Univ Pk, Nottingham NG7 2RD, England
[2] Univ Derby, Dept Mech Engn & Built Environm, Derby DE22 3AW, England
关键词
Complete dehumidification system; Liquid desiccant; Numerical modelling; Cooling capacity; COP; AIR DEHUMIDIFICATION; MASS-TRANSFER; HEAT; FLOW; COMFORT; DESIGN; MODEL;
D O I
10.1016/j.apenergy.2019.114082
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A complete membrane-based liquid desiccant dehumidification system is investigated under the steady operating condition, which mainly consists of a dehumidifier, a regenerator, three heat exchangers, a cold and a hot water supply units. A finite difference mathematical model is developed for the complete system to investigate the system dehumidification performance and energy requirement, and validated by experimental data. The dehumidification performance is evaluated by the system sensible and latent effectiveness and moisture flux rate, while its energy performance is assessed by the total cooling capacity and coefficient of performance. It is found that the number of heat transfer units in the dehumidifier side and solution to air mass flow rate ratio have the most considerable impact on the system performance, while the number of heat transfer units in the regenerator side and solution inlet concentration in the dehumidifier have comparatively weak influences. The system sensible and latent effectiveness can be improved by increasing the dehumidifier side number of heat transfer units before reaching its critical value of 6. However, the amount of moisture being absorbed, total cooling capacity and coefficient of performance decrease with the dehumidifier side number of heat transfer units at the low air flow rate. The critical value of solution to air mass flow rate ratio varies with number of heat transfer units, and it is preferable to keep the flow rate ratio at or below its critical value as further increasing solution flow rate would reduce the system coefficient of performance.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Heat and Mass Transfer Enhancement of a Multi-stage Internally-Cooled Membrane-Based Liquid Desiccant Dehumidification
    Fang, Song
    Wu, Qiao-Xian
    Rong, Yang-Yi-Ming
    Zhou, Xia
    Wang, Kai
    Qiu, Li-Min
    Zhi, Xiao-Qin
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2021, 42 (09): : 2216 - 2226
  • [32] Influences of the mixed LiCl-CaCl2 liquid desiccant solution on a membrane-based dehumidification system: Parametric analysis and mixing ratio selection
    Bai, Hongyu
    Zhu, Jie
    Chu, Junze
    Chen, Xiangjie
    Cui, Yuanlong
    Yan, Yuying
    ENERGY AND BUILDINGS, 2019, 183 : 592 - 606
  • [33] Investigation on capacity matching in a heat pump and hollow fiber membrane-based two-stage liquid desiccant hybrid air dehumidification system
    Zhang, Ning
    Yin, Shao-You
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 84 : 128 - 138
  • [34] Performance of counter flow membrane-based annular pipe liquid desiccant air conditioner
    Cihan, Ertugrul
    Kavasogullari, Baris
    Demir, Hasan
    APPLIED THERMAL ENGINEERING, 2020, 180
  • [35] Performance optimization of polymeric porous membrane-based liquid desiccant air dehumidifier used in air conditioning system
    Ali Mohammad Jafarpour
    Farivar Fazelpour
    Seyyed Abbas Mousavi
    International Journal of Energy and Environmental Engineering, 2020, 11 : 55 - 71
  • [36] Performance optimization of polymeric porous membrane-based liquid desiccant air dehumidifier used in air conditioning system
    Jafarpour, Ali Mohammad
    Fazelpour, Farivar
    Mousavi, Seyyed Abbas
    INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENTAL ENGINEERING, 2020, 11 (01) : 55 - 71
  • [37] Experimentation of a Membrane-based Concentration Gradient Energy Storage of Liquid Desiccant Solutions Driven by Solar Energy
    Wang, Zanshe
    Li, Ran
    Yin, Fangting
    Wu, Yue
    Gu, Zhaolin
    JOURNAL OF THERMAL SCIENCE, 2021, 30 (05) : 1503 - 1512
  • [38] Performance characteristics of a novel internally-cooled plate membrane liquid desiccant air dehumidification system
    Xiao, Liehui
    Yang, Minlin
    Yuan, Wu-Zhi
    Huang, Si-Min
    APPLIED THERMAL ENGINEERING, 2020, 172
  • [39] Experimentation of a Membrane-based Concentration Gradient Energy Storage of Liquid Desiccant Solutions Driven by Solar Energy
    WANG Zanshe
    LI Ran
    YIN Fangting
    WU Yue
    GU Zhaolin
    Journal of Thermal Science, 2021, 30 (05) : 1503 - 1512
  • [40] Experimentation of a Membrane-based Concentration Gradient Energy Storage of Liquid Desiccant Solutions Driven by Solar Energy
    Zanshe Wang
    Ran Li
    Fangting Yin
    Yue Wu
    Zhaolin Gu
    Journal of Thermal Science, 2021, 30 : 1503 - 1512