Experimental research on the start-up characteristics and heat transfer performance of pulsating heat pipes with rectangular channels

被引:33
|
作者
Hua, Chao [1 ]
Wang, Xuehui [1 ]
Gao, Xu [2 ]
Zheng, Haoce [1 ]
Han, Xiaohong [1 ]
Chen, Guangming [1 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Key Lab Refrigerat & Cryogen Technol Zhejiang Pro, Hangzhou 310027, Zhejiang, Peoples R China
[2] State Key Lab Technol Space Cryogen Propellants, Beijing 100028, Peoples R China
关键词
Pulsating heat pipe; Heat transfer; Large diameter; Rectangular channels; Thermal resistance; THERMAL PERFORMANCE;
D O I
10.1016/j.applthermaleng.2017.02.106
中图分类号
O414.1 [热力学];
学科分类号
摘要
As a simple and efficient heat transfer device, the pulsating heat pipe (PHP) has been considered as one of the most effective methods to meet the challenges of high heat flux. Current studies focused on the heat transfer performance of the PHP with a small diameter (d <= 3 mm). However, the PHP with a relatively large diameter has better performance due to the larger heat capacity of the working fluid at the same filling ratio. Besides, compared with the PHP with circular channels, the PHP with rectangular channels has special advantages due to the unique structures. On the basis of this, an experimental setup of the PHP with rectangular channels of 4 mm equivalent inner diameter was built, and the influence of cross-section shape on the start-up characteristics and heat transfer performance of the PHP was investigated. The experimental results showed that the start-up process shifted from a "sudden start-up mode" to a "smooth start-up mode" with the increase of heating power. The start-up heating power of the PHP with rectangular channels was (1.5-2) times greater as the heating power of the PHP with circular channels. Furthermore, the thermal resistance of the PHP with rectangular channels was only (30-40)% of the PHP with circular channels, and the temperature differences between the evaporation section and the condensation section were (10-20) degrees C lower than those of the PHP with circular channels under the same filling ratio and heat flux. It could also be concluded from the results that the lowest thermal resistance was achieved when filling ratio was 0.3 within the range of experimental data. The experimental results will provide valuable references for the optimal design of the PHP and further studies. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1058 / 1062
页数:5
相关论文
共 50 条
  • [41] Effect of tube heat conduction on the single branch pulsating heat pipe start-up
    Nikolayev, Vadim S.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 95 : 477 - 487
  • [42] Experimental study on the influence of initial state parameters on the start-up and heat transfer characteristics of separated heat pipe system
    Zhou, Xinyu
    Lv, Jun
    Cheng, Hongyan
    Fan, Guangming
    Liu, Jianhui
    ANNALS OF NUCLEAR ENERGY, 2024, 208
  • [43] A Comparative experimental Investigation into the heat transfer characteristics of pulsating heat pipes with symmetric versus asymmetric structures
    Liu, Dong
    Liu, Jianhong
    Yang, Kai
    Zheng, Chaofan
    Shang, Fumin
    Ma, Shunfang
    Xu, Haoran
    Cao, Xin
    APPLIED THERMAL ENGINEERING, 2025, 266
  • [44] Experimental study of heat transfer and start-up of loop heat pipe with multiscale porous wicks
    Ji, Xianbing
    Wang, Ye
    Xu, Jinliang
    Huang, Yanping
    APPLIED THERMAL ENGINEERING, 2017, 117 : 782 - 798
  • [45] Start-up and heat transfer characteristics of oscillating heat pipe with different check valve layouts
    Ando, Makiko
    Okamoto, Atsushi
    Nagai, Hiroki
    APPLIED THERMAL ENGINEERING, 2021, 196
  • [46] An Experimental Study of Heat Transfer Characteristics in Miniature Loop Heat Pipes with Rectangular Shaped Evaporator
    Lin, Z. R.
    Lee, Z. Y.
    Zhang, L. W.
    Wang, S. F.
    Merrikh, A. A.
    Refai-Ahmed, G.
    PROCEEDINGS OF THE ASME PACIFIC RIM TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC SYSTEMS, MEMS AND NEMS 2011, VOL 2, 2012, : 19 - +
  • [47] Experimental Study on the Start Up Performance of Flat Plate Pulsating Heat Pipe
    Chaofa Hu and Li Jia School of Mechanical
    Journal of Thermal Science, 2011, 20 (02) : 150 - 154
  • [48] Experimental study on the start up performance of flat plate pulsating heat pipe
    Chaofa Hu
    Li Jia
    Journal of Thermal Science, 2011, 20 : 150 - 154
  • [49] Experimental Study on the Start Up Performance of Flat Plate Pulsating Heat Pipe
    Hu, Chaofa
    Jia, Li
    JOURNAL OF THERMAL SCIENCE, 2011, 20 (02) : 150 - 154
  • [50] Start-up and heat transfer performance of a nitrogen cryogenic axial Ω shape grooved heat pipe
    Zhang, Chang
    Xie, Rongjian
    Sun, Qi
    Zhang, Tian
    Wu, Yinong
    Hong, Fangjun
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2019, 38 (06): : 2610 - 2617