Activation of the sensorimotor cortex at 1.O T: Comparison of echo-planar and gradient-echo imaging

被引:0
|
作者
van der Kallen, BFW [1 ]
van Erning, LJTO [1 ]
van Zuijlen, MWJ [1 ]
Merx, H [1 ]
Thijssen, HOM [1 ]
机构
[1] Univ Nijmegen Hosp, Dept Radiol, NL-6500 HB Nijmegen, Netherlands
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PURPOSE: The increasing demand for the clinical application of functional MR imaging raises the question of whether this technique can be routinely performed on 1.0-T MR scanners. To this end, we assessed the feasibility of functional MR imaging at 1.0 T, METHODS: Healthy volunteers were scanned during the performance of a motor task. Functional data were acquired with echo-planar imaging (EPI) and with gradient-echo (GRF) and dual-echo GRE sequences. The signal intensity variations of the EPI and GRE sequences were compared, and the influence of inflow and blood oxygen level-dependent (BOLD) effects on the signal variations was assessed with the dual-echo GRF sequences. RESULTS: In 11 of the 12 subjects we found activation in the primary motor cortex with both the GRE and EPI sequences. Active voxels had a significantly higher mean percentage of signal changes with the EPI sequence than with the GRE sequence (EPI: 1% to 6.1%, mean 2.4%; GRE: 1% to 4.5%, mean 1.9%), The EPI sequence was less sensitive to motion artifacts and enabled imaging of a larger brain volume in a shorter time. With a dual-echo sequence we found an increasing contribution of inflow effect with an increasing percentage of signal changes, CONCLUSION: Functional MR imaging of the sensorimotor cortex can be routinely performed at 1.0 T.
引用
收藏
页码:1099 / 1104
页数:6
相关论文
共 50 条
  • [21] Echo-planar gradient-echo MRI can detect intraluminal emboli in middle cerebral artery in acute stroke
    Furui, E
    Itoh, A
    Nasu, M
    Hata, T
    Yamamoto, M
    STROKE, 2003, 34 (01) : 262 - 262
  • [22] FUNCTIONAL ECHO-PLANAR MR IMAGING AT 1.0 T
    STEHLING, MK
    SCHMITT, F
    LADEBECK, R
    RADIOLOGY, 1992, 185 : 199 - 199
  • [23] Magnetic resonance T1 gradient-echo imaging in hepatolithiasis
    F. Safar
    T. Kamura
    K. Okamuto
    K. Sasai
    F. Gejyo
    Abdominal Imaging, 2005, 30 : 297 - 302
  • [24] Magnetic resonance T1 gradient-echo imaging in hepatolithiasis
    Safar, F
    Kamura, T
    Okamuto, K
    Sasai, K
    Gejyo, F
    ABDOMINAL IMAGING, 2005, 30 (03): : 297 - 302
  • [25] Center-out echo-planar spectroscopic imaging with correction of gradient-echo phase and time Shifts (vol 70, pg 16, 2013)
    Labadie, Christian
    Hetzer, Stefan
    Schulz, Jessica
    Mildner, Toralf
    Aubert-Frecon, Monique
    Moeller, Harald E.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (05) : 1502 - 1502
  • [26] GRADIENT-ECHO MR IMAGING OF THE LUMBAR SPINE - COMPARISON WITH SPIN-ECHO TECHNIQUE
    WATANABE, AT
    TEITELBAUM, GP
    LUFKIN, RB
    TSURUDA, JS
    JINKINS, JR
    BRADLEY, WG
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (03) : 410 - 414
  • [27] Gradient preemphasis calibration in diffusion-weighted echo-planar imaging
    Papadakis, NG
    Martin, KM
    Pickard, JD
    Hall, LD
    Carpenter, TA
    Huang, CLH
    MAGNETIC RESONANCE IN MEDICINE, 2000, 44 (04) : 616 - 624
  • [28] MR PERFUSION STUDIES WITH T-1-WEIGHTED ECHO-PLANAR IMAGING
    KWONG, KK
    CHESLER, DA
    WEISSKOFF, RM
    DONAHUE, KM
    DAVIS, TL
    OSTERGAARD, L
    CAMPBELL, TA
    ROSEN, BR
    MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) : 878 - 887
  • [29] Gradient preemphasis calibration in diffusion-weighted echo-planar imaging
    Papadakis, Nikolaos G.
    Martin, Kay M.
    Pickard, John D.
    Hall, Laurance D.
    Carpenter, T. Adrian
    Huang, Christopher L.-H.
    2000, John Wiley and Sons Inc. (44)
  • [30] Validation of fast MR thermometry at 1.5 T with gradient-echo echo planar imaging sequences: phantom and clinical feasibility studies
    Cernicanu, Alexandru
    Lepetit-Coiffe, Matthieu
    Roland, Joerg
    Becker, Christoph D.
    Terraz, Sylvain
    NMR IN BIOMEDICINE, 2008, 21 (08) : 849 - 858