Non-invasive continuous cerebral temperature monitoring in patients treated with mild therapeutic hypothermia: An observational pilot study

被引:38
|
作者
Zeiner, Andrea [1 ]
Klewer, Jasper [2 ]
Sterz, Fritz [1 ]
Haugk, Moritz [1 ]
Krizanac, Danica [1 ]
Testori, Christoph [1 ]
Losert, Heidrun [1 ]
Ayati, Shervin [3 ]
Holzer, Michael [1 ]
机构
[1] Med Univ Vienna, Dept Emergency Med, A-1190 Vienna, Austria
[2] Philips, Biomed Sensor Syst, NL-5656 AE Eindhoven, Netherlands
[3] Philips Med Syst, Andover, MA 01810 USA
关键词
Cardiac arrest; Hypothermia; Intensive care; Methodology; Monitoring; Post-resuscitation period; Temperature; EUROPEAN-RESUSCITATION-COUNCIL; AMERICAN-HEART-ASSOCIATION; CARDIAC-ARREST; CORE TEMPERATURE; BRAIN TEMPERATURE; STROKE-FOUNDATION; TASK-FORCE; PROFESSIONALS; THERMOMETRY; ESOPHAGEAL;
D O I
10.1016/j.resuscitation.2010.03.018
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Aim of the study: To investigate if body temperature as measured with a prototype of a non-invasive continuous cerebral temperature sensor using the zero-heat-flow method to reflect the oesophageal temperature (core temperature) during mild therapeutic hypothermia after cardiac arrest. Methods: In patients over 18 years old with restoration of spontaneous circulation after cardiac arrest, a temperature sensor that uses the zero-heat-flow principle was placed on the forehead during the periods of cooling and re-warming. This temperature was compared to oesophageal temperature as the primary temperature-monitoring site. To assess agreement, we used the Bland-Altman approach and Lin's concordance correlation coefficient. Results: From September 2008 to April 2009, data from 19 patients were analysed. The median time from restoration of spontaneous circulation until temperature sensor application was 53 min (interguartile range, 31; 96). All sensors were removed when a core temperature of 36 C was reached. These measurements were in agreement with oesophageal temperature measurements. No allergic reaction, rash or other irritation occurred on the skin around or under the probes. Bland-Altman results showed a bias of -0.12 degrees C and 95% limits of agreement of -0.59 and +0.36 degrees C. Lin's concordance correlation coefficient was 0.98. Conclusions: Body temperature measurements using a non-invasive continuous cerebral temperature sensor prototype that uses the zero-heat-flow method accurately reflected oesophageal temperature measurements during mild therapeutic hypothermia in patients with restoration of spontaneous circulation after cardiac arrest. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:861 / 866
页数:6
相关论文
共 50 条
  • [31] Accuracy and precision of non-invasive continuous haemoglobin concentration monitoring in diabetic patients
    De Rosa, Rosanna Carmela
    Romanelli, Antonio
    AIN SHAMS JOURNAL OF ANESTHESIOLOGY, 2022, 14 (01)
  • [32] WEARABLE DEVICE FOR CONTINUOUS, NON-INVASIVE MONITORING OF ACCESS PATENCY IN HEMODIALYSIS PATIENTS
    Miller, Forrest
    Kuraguntla, David
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2023, 81 (04) : S80 - S80
  • [33] Wearable Device for Continuous, Non-Invasive Monitoring of Serum Potassium in Hemodialysis Patients
    Miller, Forrest
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2022, 33 (11): : 29 - 30
  • [34] Accuracy and precision of non-invasive continuous haemoglobin concentration monitoring in diabetic patients
    Rosanna Carmela De Rosa
    Antonio Romanelli
    Ain-Shams Journal of Anesthesiology, 14
  • [35] Thermal Index for early non-invasive assessment of brain injury in newborns treated with therapeutic hypothermia: preliminary report
    W. Walas
    A. Mączko
    Z. Halaba
    M. Bekiesińska-Figatowska
    I. Miechowicz
    D. Bandoła
    Z. Ostrowski
    M. Rojczyk
    A. J. Nowak
    Scientific Reports, 11
  • [36] Thermal Index for early non-invasive assessment of brain injury in newborns treated with therapeutic hypothermia: preliminary report
    Walas, W.
    Maczko, A.
    Halaba, Z.
    Bekiesinska-Figatowska, M.
    Miechowicz, I.
    Bandola, D.
    Ostrowski, Z.
    Rojczyk, M.
    Nowak, A. J.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [37] Perioperative non-invasive versus semi-invasive cardiac index monitoring in patients with bariatric surgery - a prospective observational study
    Lorenzen, Ulf
    Pohlmann, Markus
    Hansen, Jonathan
    Klose, Phil
    Gruenewald, Matthias
    Renner, Jochen
    Elke, Gunnar
    BMC ANESTHESIOLOGY, 2020, 20 (01)
  • [38] Perioperative non-invasive versus semi-invasive cardiac index monitoring in patients with bariatric surgery – a prospective observational study
    Ulf Lorenzen
    Markus Pohlmann
    Jonathan Hansen
    Phil Klose
    Matthias Gruenewald
    Jochen Renner
    Gunnar Elke
    BMC Anesthesiology, 20
  • [39] Clinical study of continuous non-invasive cerebrovascular autoregulation monitoring in neurosurgical ICU
    Ragauskas, A
    Daubaris, G
    Petkus, V
    Ragaisis, V
    Ursino, M
    INTRACRANIAL PRESSURE AND BRAIN MONITORING XII, 2005, 95 : 367 - 370
  • [40] Postoperative continuous non-invasive cardiac output monitoring on the ward: a feasibility study
    King, C. E.
    Kermode, A.
    Saxena, G.
    Carvelli, P.
    Edwards, M.
    Creagh-Brown, B. C.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2021, 35 (06) : 1349 - 1356